Inspection of Welded Joints of Boiler Tubes Using Visual and Penetration NDT Methods

被引:0
|
作者
Šafařík, Vilém [1 ,2 ]
Bunda, Zbyněk [1 ]
Fink, Dominik [1 ,2 ]
Volák, Josef [1 ]
机构
[1] JCT service s.r.o, Mladotice,33141, Czech Republic
[2] University of West Bohemia in Pilsen 22, Pilsen,30100, Czech Republic
来源
e-Journal of Nondestructive Testing | 2024年 / 29卷 / 01期
关键词
D O I
10.58286/29021
中图分类号
学科分类号
摘要
Nondestructive examination
引用
收藏
相关论文
共 50 条
  • [21] USING MAGNETIC INSPECTION FOR DETECTING LOCAL DEFECTS IN WELDED-JOINTS
    NOVIKOV, VA
    ROMANOV, VA
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 1994, 30 (01) : 25 - 31
  • [22] Inspection of thick welded joints using laser-ultrasonic SAFT
    Levesque, D.
    Asaumi, Y.
    Lord, M.
    Bescond, A. C.
    Hatanaka, H.
    Tagami, M.
    Monchalin, J. -P.
    ULTRASONICS, 2016, 69 : 236 - 242
  • [23] An Application to Welded Joints of the Crack Inspection System by Using Magnetic Properties
    Hashimoto, Kiyoshi
    Osawa, Naoki
    Sawamura, Junji
    Asai, Hiroshi
    PROCEEDINGS OF THE EIGHTEENTH (2008) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 4, 2008, : 341 - 344
  • [24] LONG-TERM CREEP RUPTURE STRENGTH PREDICITION AND FAILURE MECHANISMS OF WELDED JOINTS OF BOILER TUBES AND PIPES
    Kubon, Zdenek
    METAL 2016: 25TH ANNIVERSARY INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS, 2016, : 753 - 758
  • [25] Eddy-current inspection of welded joints of electric-welding tubes with measurement result visualization
    VNIINM im. A.A. Bochvara, Moscow, Russia
    At Energ, 6 (416-419):
  • [26] ULTRASONIC INSPECTION OF AUSTENITIC WELDED-JOINTS - ANALYSIS OF METHODS AND RECOMMENDATIONS FOR IMPROVING RELIABILITY
    ALESHIN, NP
    VADKOVSKII, NN
    VOLKOVA, NN
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1988, 24 (02): : 109 - 124
  • [27] Detection of surface defects in welded joints during visual inspections using machine vision methods br
    Yemelyanova, M. G.
    Smailova, S. S.
    Baklanova, O. E.
    COMPUTER OPTICS, 2023, 47 (01) : 112 - +
  • [28] TEST OBJECT FOR VISUAL ESTIMATION OF SIZE OF INTERNAL DEFECTS IN WELDED-JOINTS IN FLUOROSCOPIC INSPECTION
    TOKMAKOV, VS
    MOISH, YV
    WELDING PRODUCTION, 1975, 22 (10): : 65 - 66
  • [29] AUTOMATING DATA ANALYSIS DURING THE INSPECTION OF BOILER TUBES USING LINE SCANNING THERMOGRAPHY
    Ley, Obdulia
    Momeni, Sepand
    Ostroff, Jason
    Godinez, Valery
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 31A AND 31B, 2012, 1430 : 499 - 506
  • [30] Some aspects of using piezoelectric probes for ultrasonic inspection of thin welded joints
    V. M. Ushakov
    V. V. Mikhalev
    Russian Journal of Nondestructive Testing, 2007, 43 : 204 - 209