Effects of hygrothermal environment on quasi-static failure of CFRP composite-aluminum alloy bolted joints

被引:0
作者
Zhang J. [1 ]
Shan M. [2 ]
Huang W. [3 ]
Zhao L. [1 ]
机构
[1] School of Astronautics, Beihang University, Beijing
[2] Department of Mechanics, School of Civil Engineering, Beijing Jiaotong University, Beijing
[3] Hubei Aerospace Flight Vehicle Institute, Wuhan
来源
Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica | 2021年 / 38卷 / 07期
关键词
Bolted joint; Carbon fiber reinforced polymer composite; Ductile damage criteria; Failure; Hygrothermal environment; Progressive damage;
D O I
10.13801/j.cnki.fhclxb.20200927.002
中图分类号
学科分类号
摘要
The significant influence of the hygrothermal environment on the failure of the carbon fiber reinforced polymer (CFRP) composite-aluminum alloy bolted joints has threatened the safety of the overall structures. In order to accurately assess the influence of hygrothermal environment on the quasi-static failure of CFRP composite-metal bolted joints, a quasi-static failure prediction model of composite-metal bolted joints considering hygrothermal effects was established, based on the existing progressive damage analysis of composites and Ductile damage criteria of metal. This model is validated by good consistency between the numerical and experimental results of CFRP composite-aluminum alloy single-bolt double-lap joints under 23℃/dry and 70℃/wet conditions, respectively. The proposed model was further used to reveal the influence laws of different hygrothermal environments on the quasi-static tensile failure of CFRP composite-aluminum alloy single-bolt double-lap and multi-bolt double-lap joints. The research shows that the failure loads of the single-bolt double-lap joints under 23℃/wet condition, 70℃/dry condition and 70℃/wet condition are reduced by 4.5%, 7.2% and 13.9%, respectively, compared with 23℃/dry condition. The high temperature condition is the main factor that leads to the increase of the failure area above the CFRP composite laminate under hygrothermal environments. As the number of the bolt increases, the declining degree of the quasi-static failure strength under 70℃/wet condition decreases gradually compared with 23℃/dry condition. © 2021, Editorial Office of Acta Materiae Compositae Sinica. All right reserved.
引用
收藏
页码:2224 / 2233
页数:9
相关论文
共 25 条
  • [1] JARED T, YIKAI Y, JEFFREY Y, Et al., Environmentally assisted crack growth in adhesively bonded composite joints, Composites Part A: Applied Science and Manufacturing, 102, pp. 368-377, (2017)
  • [2] GONG Y, ZHAO L B, ZHANG J Y, Et al., A novel model for determining the fatigue delamination resistance in composite laminates from a viewpoint of energy, Composites Science and Technology, 167, pp. 489-496, (2018)
  • [3] ZHANG J Y, QI D X, ZHOU L W, Et al., A progressive failure analysis model for composite structures in hygrothermal environments, Composite Structures, 133, pp. 331-342, (2015)
  • [4] GUO J S., Internal stress analysis of bolted joints composed of composte plate and aluminum plate in thermal field, (2013)
  • [5] KAPIDZIC Z, ANSELL H, SCHON J, Et al., Fatigue bearing failure of CFRP composite in bolted joints exposed to biaxial variable amplitude loading at elevated temperature, Composite Structures, 142, pp. 71-77, (2016)
  • [6] PEI R G, XIAO Y, CHEN H L, Et al., Temperature-time dependent behavior for preload relaxation in bolted composite joints, Acta Materiae Compositae Sinica, 33, 4, pp. 768-778, (2016)
  • [7] TURVEY G J, SANA A., Pultruded GFRP double-lap single-bolt tension joints: Temperature effects on mean and characteristic failure stresses and knock-down factors, Composite Structures, 153, pp. 624-631, (2016)
  • [8] LI H L, ZHANG K F, CHENG H, Et al., Multi-stage mechanical behavior and failure mechanism analysis of CFRP/Al single-lap bolted joints with different seawater ageing conditions, Composite Structures, 208, pp. 634-645, (2019)
  • [9] MIYANO Y, NAKADA M, SEKINE N., Life prediction of CFRP/metal bolted joint under water absorption condition, Journal of Composite Materials, 44, 20, pp. 2393-2411, (2010)
  • [10] MARIAM M, AFENDI M, ABDUL M M S, Et al., Hydrothermal ageing effect on the mechanical behaviour and fatigue response of aluminium alloy/glass/epoxy hybrid composite single lap joints, Composites Structures, 219, pp. 69-82, (2019)