Fire Resistance Analysis of RC Beam Supporting Column Transfer Structure Joints

被引:0
作者
Kong W. [1 ]
Fu C. [2 ]
Liu W. [3 ]
机构
[1] College of Civil Engineering, Southeast University, Nanjing
[2] College of Civil Engineering, Shandong Jianzhu University, Jinan
[3] College of Civil Engineering, Nanjing Tech University, Nanjing
来源
Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University | 2019年 / 54卷 / 03期
关键词
Beam supporting column transfer structure joints; Fire resistance; High temperature; Reinforced concrete; Transfer structure;
D O I
10.3969/j.issn.0258-2724.20170875
中图分类号
学科分类号
摘要
To provide the basis for the fire prevention design of reinforced concrete beam supporting column transfer structures, according to the structural characteristics, two kinds of full size beam supporting column transfer structure joints are designed. The reinforced concrete beam supporting column transfer structure joints are exposed to fire, and their fire resistance is tested. Based on the test results, using ABAQUS -a finite element analysis software, considering the influence of raising temperature curve, loading ratio, protective layer thickness, additional steel bars, the number of surfaces in fire of a transfer girder, the fire resistance of beam supporting column transfer structure joints is analyzed and the variation of the fire resistance for these beam supporting column transfer structure joints is summarized. The analysis results show that heating curve and maximum temperature have a significant influence on fire resistance; the fire resistance limit of joint units with load ratio of 0.6 is smaller than that of joint units with load ratio of 0.4; the thickness of the protective layer of the longitudinal tensile reinforcement of the joint unit differs, while the fire resistance limit ranges from large to small for protective layer thickness of 50 mm, 40 mm, and 25 mm, respectively; hanging steel bars in the transfer girder can improve the fire resistance and help avoid sudden damage. The more surfaces of the transfer girder are in fire, the shorter is the fire resistance. Under the same loading ratio, two kinds of beam supporting column transfer structure joints have different damage characteristics and fire resistance. © 2019, Editorial Department of Journal of Southwest Jiaotong University. All right reserved.
引用
收藏
页码:548 / 555
页数:7
相关论文
共 7 条
  • [1] Li G., Wu B., Han L., Development of research on fire resistance of structures, Progress in Steel Building Strectures, 8, 1, pp. 1-13, (2006)
  • [2] Fu C., Kong W., Song S., Et al., Deformation analysis of reinforced concrete structure with bearing column girder transfer floor under fire conditions, Journal of Building Structures, 36, pp. 175-182, (2015)
  • [3] Kong W., Fu C., Chu F., Et al., Thermal mechanical coupling analysis of reinforced concrete transfer structure with superimposed vierendeel truss, Journal of Disaster Prevention and Mitigation Engineering, 36, 3, pp. 386-393, (2016)
  • [4] Fire-resistance tests elements of building construction: ISO 834, (1980)
  • [5] Lie T.T., Denham E.M.A., Factors affecting the fire resistance of circular hollow steel columns filled with bar-reinforced concrete, (1993)
  • [6] Lie T.T., Lin T.D., Allen D.E., Et al., Fire resistance of reinforced concrete columns, (1984)
  • [7] Eurocode 3, design of steel structures, part 1-2: structural fire design: ENV 1993-1-2, (1993)