Near-infrared C2H4 Detection Based on Calibrated Direct Absorption Spectroscopy

被引:0
|
作者
Wang Q. [1 ,2 ]
Sun P. [2 ]
Zhang Z. [1 ,2 ,3 ,4 ]
Cai Y. [5 ]
Huang W. [1 ,2 ]
Pang T. [2 ]
Xia H. [2 ]
Wu B. [2 ]
机构
[1] School of Environment Science and Optoelectronic Technology, University of Science and Technology of China, Anhui, Hefei
[2] Anhui Provincial Key Laboratory of Photonic Devices and Materials, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui, Hefei
[3] Key Lab of Environmental Optics & Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui, Hefei
[4] Advanced Laser Technology Laboratory of Anhui Province, National University of Defense Technology, Anhui, Hefei
[5] PipeChina General Academy of Science & Technology, Hebei, Langfang
来源
Zhongguo Jiguang/Chinese Journal of Lasers | 2024年 / 51卷 / 08期
关键词
band absorption; calibrated direct absorption spectroscopy; ethylene gas (C[!sub]2[!/sub]H[!sub]4[!/sub]); high-precision pressure control; near-infrared spectroscopy; spectroscopy;
D O I
10.3788/CJL231597
中图分类号
学科分类号
摘要
Objective The real-time detection of ethylene (C2H4) is significant for the safety of coal mines, the petrochemical industry, and other industries. Currently, the mainstream methods for C2H4 gas concentration detection include gas chromatography and electrochemical sensors. Gas chromatography can separate multicomponent gases and avoid mutual interference. However, this method requires long-term preheating and frequent calibration, making it difficult to complete real-time measurements in industrial scenarios. Although electrochemical sensors have the advantages of small size and low cost, their selectivity is poor, and it is difficult to avoid cross-interference. In contrast, tunable diode laser absorption spectroscopy (TDLAS) has the advantages of real-time measurements, high sensitivity, and strong selectivity. They are widely used in industrial gas detection and environmental monitoring. Unfortunately, there are still some difficulties in real-time high-precision detection of C2H4. First, information regarding the absorption line of C2H4 in the near-infrared band cannot be obtained. Second, the absorption spectrum of C2H4 is described as complex band absorption. Third, the absorption spectra of C2H4 and CH4 in the near-infrared band interfere with each other. Therefore, realtime high-precision detection of C2H4 is a common problem that urgently needs to be addressed. Methods First, the gas concentration can be calculated using traditional direct absorption spectroscopy if the accurate parameters of the absorption line are known. However, for C2H4, it does not contain an absorption line intensity within the near-infrared band in the HITRAN database. This results in an inability to use a calibration-free method to directly calculate the C2H4 concentration. Notably, the concentration calculation method in wavelength modulation spectroscopy does not require accurate spectral line intensity. Therefore, the calibration concept of wavelength modulation spectroscopy is applied to the direct absorption spectroscopy, forming a method named calibrated direct absorption spectroscopy. In addition, faced with the problems of the band absorption of C2H4 and the interference of CH4, a high-precision pressure control system is utilized to complete the spectral line separation under low pressure. In contrast to previous studies, it is necessary to select an appropriately calibrated spectrum in this study. Specifically, standard CH4 and C2H4 gases are measured at a pressure of 100 mbar (1 bar=105 Pa) and the corresponding direct absorption spectra are obtained. By comparing with the simulated spectrum of CH4 in the HITRAN database, the appropriate calibrated spectrum of C2H4 is determined. Results and Discussions Stable pressure plays a vital role in the experiments. After the pressure value stabilizes to 100 mbar, the pressure results of the continuous measurement within 1 h are collected, and the distribution of the pressure results is well fitted by a Gaussian function; the full width at half maximum is 0.008 mbar, which proves the stability of the experimental system for pressure control. The subsequent experiments are conducted at 100 mbar. Within the volume fraction of less than 100×10-6, the direct absorption spectrum signals of five sets of C2H4 are acquired and the concentration results are also calculated. The correlated coefficient of linear fitting between the result and the standard concentration is greater than 0.999, and the maximum measurement error is -1.47×10-6. In addition, a direct absorption spectrum signal of 10×10-6 C2H4 is selected for limit of detection (LoD) analysis. The peak value of the signal is 5.80×10-4, and that of the background signal is 0.80×10-4, which can be calculated to obtain a signal-to-noise ratio (SNR) of 7.25. The concentration corresponding to one SNR is defined as the LoD, and its value is 1.38×10-6. Finally, C2H4 with a volume fraction of 20×10-6 is continuously measured for 40 min, and Allan variance analysis is performed on the volume fraction results. At an integral time of 1 s, the precision of measurement for C2H4 is 0.61×10-6. As the integral time increases, the detection precision can reach 0.04×10-6. Conclusions To address the challenges faced in near-infrared ethylene detection, a calibrated method in wavelength modulation spectroscopy is applied to direct absorption spectroscopy, forming a new method known as calibrated direct absorption spectroscopy. An experimental device for C2H4 detection with a high-precision pressure-control system is established, and the direct absorption spectrum of C2H4 is measured at approximately 1626 nm. Based on experimental verification, the calibrated direct absorption spectroscopy method can complete the real-time detection of C2H4, overcoming the limitations of traditional direct absorption spectroscopy. We also hope to address real-time detection problems of other similar gases, which can significantly expand the application of direct absorption spectroscopy. © 2024 Science Press. All rights reserved.
引用
收藏
相关论文
共 29 条
  • [1] Chen K, Zhang B, Guo M, Et al., Photoacoustic trace gas detection of ethylene in high-concentration methane background based on dual light sources and fiber-optic microphone, Sensors and Actuators B: Chemical, 310, (2020)
  • [2] Xie J, Xue S, Cheng W M, Et al., Early detection of spontaneous combustion of coal in underground coal mines with development of an ethylene enriching system, International Journal of Coal Geology, 85, 1, pp. 123-127, (2011)
  • [3] Deng J, Xiao Y, Li Q W, Et al., Experimental studies of spontaneous combustion and anaerobic cooling of coal, Fuel, 157, pp. 261-269, (2015)
  • [4] Chen Y, Gao G Z, Cai T D., Detection technique of ethylene based on photoacoustic spectroscopy, Chinese Journal of Lasers, 44, 5, (2017)
  • [5] Tanaka K, Akishima K, Sekita M, Et al., Measurement of ethylene in combustion exhaust using a 3.3- μm distributed feedback interband cascade laser with wavelength modulation spectroscopy, Applied Physics B, 123, 8, (2017)
  • [6] Teodoro C G, Schramm D U, Sthel M S, Et al., CO<sub>2</sub> laser photoacoustic detection of ethylene emitted by diesel engines used in urban public transports, Infrared Physics & Technology, 53, 2, pp. 151-155, (2010)
  • [7] Zhang L W, Zhang Z R, Wang Q J, Et al., A sensitive carbon monoxide sensor for industrial process control based on laser absorption spectroscopy with a 2.3 μm distributed feedback laser, Optics and Lasers in Engineering, 152, (2022)
  • [8] Sun L Q, Zou M L, Wang X., Application of tunable diode laser absorption spectroscopy in breath diagnosis, Chinese Journal of Lasers, 48, 15, (2021)
  • [9] Pang T, Sun P S, Zhang Z R, Et al., Design of compact full-range laser methane sensor with wide temperature range, Acta Photonica Sinica, 49, 10, (2020)
  • [10] Liu N W, Xu L G, Zhou S, Et al., Simultaneous detection of multiple atmospheric components using an NIR and MIR laser hybrid gas sensing system, ACS Sensors, 5, 11, pp. 3607-3616, (2020)