STUDY ON A SIMPLIFIED MODEL OF A HIGH-RISE SHEAR-TYPE BUILDING FOR EVALUATION OF Q–Δ RESONANCE

被引:0
作者
Anamizu R. [1 ]
Kohiyama M. [2 ]
机构
[1] School of Science for Open and Environmental Systems, Graduate School of Science and Technology, Keio University
[2] Dept. of System Design Engineering, Faculty of Science and Technology, Keio University
来源
Journal of Structural and Construction Engineering | 2023年 / 88卷 / 803期
基金
日本学术振兴会;
关键词
Geometric non-linearity; High-rise building; Non-eccentric building; Shaking table test; Torsional vibration;
D O I
10.3130/aijs.88.59
中图分类号
学科分类号
摘要
To evaluate Q–Δ resonance, which is a torsional resonance phenomenon caused by geometric non-linearity, we proposed a simplified model for an n-story non-eccentric building model with a shear-type structure. We designed and fabricated a four-story small-scale specimen assuming a non-eccentric steel structure with a height of 324 m, and conducted shaking table tests. As a result, the occurrence of Q–Δ resonance was confirmed as predicted by the simplified model. In addition, the simplified model reproduced the resonance amplitude in a finite element model of the specimen with the out-of-plane rotation of slabs constrained and its validity was confirmed. © 2023 Authors. All rights reserved.
引用
收藏
页码:59 / 70
页数:11
相关论文
共 25 条
  • [11] Mizutori F., Kohiyama M., Experiment of Torsional Response Induced by the Q–Delta Resonance, Structural Design of Tall and Special Buildings, 30, 4, (2021)
  • [12] Anamizu R., Kohiyama M., Fundamental Study of Q-Δ Resonance Considering Higher-Order Modes by Shaking Table Experiments and Finite Element Analysis, Journal of Structural Engineering (Transaction of AIJ), 68B, (2022)
  • [13] Caughey T. K., Classical Normal Modes in Damped Linear Dynamic Systems, J. Applied Mechanics, ASME, 27, 2, pp. 269-271, (1960)
  • [14] Caughey T. K., O'Kelly M. E. J., Classical Normal Modes in Damped Linear Dynamic Systems, J. Applied Mechanics, ASME, 32, 3, pp. 583-588, (1965)
  • [15] Takeichi N., Gouda Y., Fire Safety Planning for Abeno Harukas, GBRC, 39, 1, (2014)
  • [16] General Buildings, Database of Measured Damping of Various Buildings, (2020)
  • [17] Tabatabaiefar H. R., Mansoury B., Detail Design, Building and Commissioning of Tall Building Structural Models for Experimental Shaking Table Tests, Struct. Design Tall Spec. Build, pp. 357-374, (2016)
  • [18] Katayama T., System Identification-Approach from Subspace Method, pp. 101-285, (2004)
  • [19] Hida T., Nagano M., Estimation Accuracy of Natural Frequency and Damping Factor of Building by System Identification Based on Three Subspace Methods, Journal of Structural and Construction Engineering (Transaction of AIJ), 79, 701, pp. 923-932, (2014)
  • [20] Special Page for Release of Technical Materials and Data Related to Countermeasures Against Long-Period Seismic Motion