Fluorescent penetrant testing by means of excilamps

被引:1
作者
Kalinichenko A. [1 ]
Sosnin E. [2 ]
Avdeev S. [2 ]
Kalinichenko N.
Lobanova I. [1 ]
机构
[1] Tomsk Polytechnic University, 30 Lenin Avenue, Tomsk
[2] Institute of High Current Electronics SB RAS, 2/3 Akademichesky Avenue, Tomsk
关键词
Excilamp; Fluorescent method; LED UV flashlight; Penetrant testing; Test sample; Ultraviolet radiation; UV lamp;
D O I
10.4028/www.scientific.net/MSF.942.131
中图分类号
学科分类号
摘要
The paper provides a brief review of modern sources of ultraviolet (UV) radiation used in fluorescent penetrant testing (FT). The differences in implementation of the method with different radiation sources (excilamps, mercury UV lamp and LED UV lamp) are revealed experimentally. It is shown that the XeCl excilamp is not inferior to other sources of UV radiation used in FT. © 2019 Trans Tech Publications, Switzerland.
引用
收藏
页码:131 / 140
页数:9
相关论文
共 20 条
  • [1] Greissel M., NDT shows strong growth, Quality, 42, pp. 4-5, (2003)
  • [2] Ordonez B.J., Walker K., Ban on Mercury Vapor Bulbs in Black Lights, 5Th Pan American Conference for NDT, (2011)
  • [3] Link R., Ivankov A., Riess N., Technological status of led techniques-Application in non destructive testing with special emphasis on magnetic particle, penetrant, visual and thermographic inspection, 14th International Conference of the Slovenian Society for Non-Destructive Testing: Application of Contemporary Non-Destructive Testing in Engineering, St. Bernardin/Portoroz, Slovenia, pp. 145-154, (2017)
  • [4] Lunin B., Torbin S., The formation of defects in the surface of quartz glass during heat treatment, MSU Vestnik, Series. 2, Chemistry, 46, pp. 378-381, (2005)
  • [5] Sfarra S., Ibarra-Castanedo C., Ambrosini D., Paoletti D., Bendada A., Maldague X., Discovering the defects in paintings using non-destructive testing (NDT) techniques and passing through measurements of deformation, Journal of Nondestructive Evaluation, 33, pp. 358-383, (2014)
  • [6] Breit M., Advantages, Risks and Prospects of the Usage of UV-LED-Sources (365 nm) for Fluorescence Stimulation in NDT, 18Th World Conference on Nondestructive Testing, (2012)
  • [7] Prokhorenko P.P., Migun N.P., Grebenshchikov S.V., Experimental studies of polar indicator liquids used in capillary penetrant testing, International Journal of Engineering Science, 25, pp. 769-773, (1987)
  • [8] Sosnin E.A., Oppenlander T., Tarasenko V.F., Applications of Capacitive and Barrier Discharge Excilamps in Photoscience, Journal Photochemistry and Photobiology, 7, pp. 145-163, (2006)
  • [9] Lomaev M.I., Skakun V.S., Sosnin E.A., Tarasenko V.F., Shitts D.V., Erofeev M.V., Excilamps: Efficient sources of spontaneous UV and VUV radiation, Phys. Usp., 2, pp. 193-210, (2003)
  • [10] Boyd I.W., Zhang J.-Y., Kogelschatz U., Development and Applications of UV Excimer Lamps, Photo-Excited Processes, Diagnostics and Applications, pp. 161-199, (2003)