Treatment of selected distal radius fractures with nonbridging external fixation

被引:2
|
作者
Hajianpour M.A. [1 ]
Sheikh B. [1 ]
Feanny M. [1 ]
Berkowitz M. [1 ]
Latta L. [2 ]
机构
[1] Total Orthopaedic Care, Lauderdale Lakes, 33313, FL
[2] Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, 33136, FL
关键词
Colles; fractures; Distal radius fractures; External fixation;
D O I
10.1615/JLongTermEffMedImplants.2020036110
中图分类号
学科分类号
摘要
A nonbridging external fixation (NBX) system with 1.6-mm diameter pins provided excellent stability for distal radius fractures in cadavers. For the present study, all patients with distal radius fractures were seen by the surgeon authors. Fractures that were displaced and unstable, including Orthopaedic Trauma Association (OTA) types 23-A2.3 to C3.3, were reduced and fixed with the NBX system. The Western Institutional Review Board granted approval (296864) for this retrospective study. Fractures numbered five OTA-A2, eight OTA-A3, two OTA-B3, one OTA-C1, two OTA-C2, and eight OTA-C3. In total, the study included 26 patients. At fixator removal, average dorsiflexion was 37.0° ± 17.8°; volar flexion, 39.4° ± 17.2°; pronation, 80.6° ± 16.1°; and supination, 48.1° ± 24.2°. Follow-up averaged 11.7 mo ± 19.2 mo. At final follow-up, average dorsiflexion was 52.9° ± 25.0°; volar flexion, 53.1° ± 23.7°; pronation, 80.8° ± 14.5°; and supination, 67.7° ± 30.3°. Average radial tilt at the time of injury was 11.6° ± 8.3°; post op to 23.9° ± 5.0°; and at last follow-up, 23.1° ± 5.0°. Average radial styloid length at the time of injury was 4.1 mm ± 3.7 mm; post op to 11.4 mm ± 3.0 mm; and at last follow-up, 10.5 mm ± 3.1 mm. Volar tilt at the time of injury averaged –19.6° ± 14.8°; reduced to 9.8° ± 6.3°; and at last follow-up, 7.5° ± 6.5°. This form of nonbridging fixation is safe and effective at maintaining reduced, extra-and intra-articular, distal radius fractures and allows functional range of motion with minimal complications. © 2020 by Begell House.
引用
收藏
页码:199 / 204
页数:5
相关论文
共 50 条
  • [31] Efficacy of non-bridging external fixation in treating distal radius fractures
    Liu, Ying
    Bai, Yu-ming
    ORTHOPAEDIC SURGERY, 2020, 12 (03) : 776 - 783
  • [32] Radio-radial external fixation in the treatment of distal radius fractures allows for free wrist motion
    Gradl, G
    Gierer, P
    Ewert, A
    Beck, M
    Mittlmeier, T
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (12): : 1014 - 1019
  • [33] Dynamic and static external fixation for distal radius fractures-A systematic review
    Modi, Chetan S.
    Ho, Kevin
    Smith, Chris D.
    Boer, Ronald
    Turner, Stephen M.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1006 - 1011
  • [34] Treatment Strategies of Distal Radius Fractures
    Bales, Joshua G.
    Stern, Peter J.
    HAND CLINICS, 2012, 28 (02) : 177 - +
  • [35] Displaced Intra-Articular Fractures of the Distal Radius: Open Reduction With Internal Fixation Versus Bridging External Fixation
    Fakoor, Mohammad
    Fakoor, Morteza
    Mohammadhoseini, Payam
    TRAUMA MONTHLY, 2015, 20 (03)
  • [36] Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures
    Kumbaraci M.
    Kucuk L.
    Karapinar L.
    Kurt C.
    Coskunol E.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) : 173 - 178
  • [37] A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures
    Margaliot, Z
    Haase, SC
    Kotsis, SV
    Kim, HM
    Chung, KC
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (06): : 1185 - 1199
  • [38] Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis
    Gouk, Conor J. C.
    Bindra, Randip R.
    Tarrant, Drew J.
    Thomas, Michael J. E.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) : 954 - 960
  • [39] Distal Radius Fractures: Indications for Plate Fixation
    Larsen, Morten Schultz
    EUROPEAN INSTRUCTIONAL LECTURES, VOL 15, 2015, 15 : 89 - 100
  • [40] Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures
    Han, L. R.
    Jin, C. X.
    Yan, J.
    Han, S. Z.
    He, X. B.
    Yang, X. F.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (01) : 2912 - 2919