Optimal Configuration of Arresters for Suppressing Power Frequency Overvoltage in Half-wavelength Transmission System

被引:0
|
作者
Yi J. [1 ]
Hu W. [2 ]
Chen X. [3 ]
Qiu L. [3 ]
Zhang Z. [3 ]
Hu B. [3 ]
Li C. [3 ]
机构
[1] China Electric Power Research Institute, Haidian District, Beijing
[2] State Key Lab of Control And Simulation of Power System and Generation Equipments, Dept. of Electrical Engineering, Tsinghua University, Haidian District, Beijing
[3] Hunan Key Laboratory of Intelligent Information Analysis and Integrated Optimization for Energy Internet, Hunan University, Changsha, 410082, Hunan Province
来源
关键词
Half-wavelength AC transmission; Metal-oxide surge arresters; Overvoltage; Overvoltage suppression; Ultra-high voltage;
D O I
10.13335/j.1000-3673.pst.2018.0769
中图分类号
学科分类号
摘要
Ultra-high voltage (UHV) half-wavelength AC transmission technology can achieve long-distance and large-capacity power transmission. This technology is of great significance for UHV transmission network construction and accommodation of clean energy throughout China. However, in cases of no-load lines, load rejection or short-circuit fault, there will be different levels of overvoltage along the UHV half-wavelength AC transmission lines. Aiming at this problem, this paper proposes a metal-oxide surge arrester optimal configuration method along the lines to suppress the overvoltage. The characteristics of overvoltage in half-wavelength AC transmission system is analyzed and the theory of using metal-oxide surge arresters to suppress power frequency overvoltage is studied. On this basis, the optimal metal-oxide surge arresters' configuration scheme along the lines is proposed. Then a simulation model is established using typical parameters of UHV half-wavelength AC transmission system to compare the overvoltage levels between conventional configuration without the arresters and optimal configuration with the arresters. Simulation results show that the configuration scheme with 11 or more metal-oxide surge arresters along the UHV half-wavelength transmission lines can suppress the overvoltage effectively and well satisfy single metal-oxide surge arrester's flow capacity. The research results provide an effective solution for suppressing overvoltage of the UHV half-wavelength AC power transmission system. © 2019, Power System Technology Press. All right reserved.
引用
收藏
页码:2227 / 2234
页数:7
相关论文
共 18 条
  • [1] Sun K., Yi Q., Dong C., Et al., Research on power frequency over-voltage in UHV AC transmission lines, Power System Technology, 34, 12, pp. 30-35, (2010)
  • [2] Zhang Y., Ban L., Chen W., Et al., Research on diversities of power frequency overvoltage of UHV AC transmission systems, Power System Technology, 38, 7, pp. 1765-1771, (2014)
  • [3] Zhou J., Ma J., Xu H., Et al., Steady state and transient operational characteristics of UHV half-wavelength AC transmission systems, Power System Technology, 35, 9, pp. 28-32, (2011)
  • [4] Liang X., Zhang Y., Qin X., Et al., Study on construction of three dimensional power grid based on UHV AC half-wavelength technology, Power System Technology, 40, 11, pp. 3415-3419, (2016)
  • [5] Zhang L., Zou L., Lv X., Et al., Power frequency temporary overvoltage on half-wave length transmission lines, High Voltage Engineering, 38, 10, pp. 2728-2734, (2012)
  • [6] Hubert F.J., Gent M.R., Half-wavelength power transmission lines, IEEE Transactions on Power Apparatus and Systems, 84, 10, pp. 965-974, (1965)
  • [7] Prabhakara F.S., Parthasarathy K., Rao H.N.R., Analysis of natural half-wave-length power transmission lines, IEEE Transactions on Power Apparatus and Systems, 88, 12, pp. 1787-1794, (1969)
  • [8] Zhang Y., Discussion on several problems of UHV transmission planning in China, Power System Technology, 29, 19, pp. 11-14, (2005)
  • [9] Du D., Wang X., Liu H., Et al., Study on fault characteristics of half-wavelength AC transmission line and its impaction to transmission line protection, Proceedings of the CSEE, 36, 24, pp. 6788-6795, (2016)
  • [10] Qin X., Zhang Z., Xu Z., Et al., Study on steady state characteristics and transient stability of UHV half-wavelength AC transmission system based on quasi steady state model, Proceedings of the CSEE, 31, 31, pp. 66-76, (2011)