Signal crosstalk correction for flat panel detector based on image deconvolution

被引:0
作者
An K. [1 ,2 ]
Shu H. [1 ,2 ]
Lu Y. [1 ,2 ]
Zhou R. [1 ,2 ]
Wang J. [1 ,2 ]
机构
[1] Key Laboratory of Optoelectronic Technology and System, Ministry of Education, College of Photoelectric Engineering, Chongqing University, Chongqing
[2] Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Chongqing
来源
Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument | 2023年 / 44卷 / 07期
关键词
cone-beam CT; crosstalk correction; flat panel detector; PSF; spatial resolution;
D O I
10.19650/j.cnki.cjsi.2311385
中图分类号
学科分类号
摘要
The flat panel detector is a key component of cone-beam CT, and the signal crosstalk between pixels is the main factor that causes the spatial resolution of the projection image to be lower than the possible highest resolution of the flat panel detector. It is essential to correct the signal crosstalk of the flat panel detector for improving the detection accuracy of cone-beam CT. In this article, the crosstalk correction effect of the point spread function matrices with different accuracy, the relationship between the point spread function and line spread function, and the similarity between the relationship and X-ray imaging are studied, based on the signal crosstalk correction idea of the point spread function matrix deconvoluting projection image. In addition, a new method for calculating the point spread function matrix of a flat panel detector is proposed, which combines the knife edge method for measuring line spread function with parallel-beam CT scanning reconstruction. In DR / CT scanning experiments, the spatial resolution of DR projection image is improved from about 10 lp / mm to better than 25 lp / mm and the spatial resolution of high-energy CT image is improved from less than 4 lp / mm to better than 5 lp / mm after correcting signal crosstalk by the proposed method. Experimental results show that the proposed method can effectively correct the signal crosstalk of flat panel detector and improve the spatial resolution and contrast of cone-beam CT images. © 2023 Science Press. All rights reserved.
引用
收藏
页码:194 / 202
页数:8
相关论文
共 23 条
  • [11] WU P, BOONE J M, HERNANDEZ A M, Et al., Theory, method, and test tools for determination of 3D MTF characteristics in cone-beam CT, Medical Physics, 48, 6, pp. 2772-2789, (2021)
  • [12] SUN CH M, TANG G P, WANG Z Y, Et al., Analysis of MTF in digital radiography using linear detector array, Nuclear Techniques, 39, 7, pp. 41-48, (2016)
  • [13] MELNYK R, DIBIANCA F A., Modeling and measurement of the detector presampling MTF of a variable resolution X-ray CT scanner, Medical Physics, 34, 3, pp. 1062-1075, (2007)
  • [14] LI M, LIU J, YANG W, Et al., Structure-revealing low-light image enhancement via robust retinex model, IEEE Transactions on Image Processing, 27, 6, pp. 2828-2841, (2018)
  • [15] ZHANG W H, LI G, YING Z Q, Et al., A new underwater image enhancing method via color correction and illumination adjustment [ C ], IEEE Visual Communications and Image Processing (VCIP), pp. 1-4, (2017)
  • [16] DENG G, GALETTO F, ALNASRAWI M, Et al., A guided edge-aware smoothing-sharpening filter based on patch interpolation model and generalized gamma distribution [ J ], IEEE Open Journal of Signal Processing, 2, pp. 119-135, (2021)
  • [17] DEMIR Y, KAPLAN N H., Low-light image enhancement based on sharpening-smoothing image filter, Digital Signal Processing, 138, (2023)
  • [18] SHAO J M, LU H N, CAI H., Research of X-ray imaging system point spread function in theory and experiment, Optical Technique, 1, pp. 104-106, (2005)
  • [19] SUN SH Z, LIU J Y, SHI B J., Restration and recognition of blurred image of instrument based on improved PSF parameter estimation, Transducer and Microsystem Technologies, 41, 9, pp. 109-112, (2022)
  • [20] LEE J M, LEE J H, PARK K T, Et al., Image deblurring based on the estimation of PSF parameters and the post-processing, Optik, 124, 15, pp. 2224-2228, (2013)