Electric Potential Structure in the Extraction Region of the Negative Hydrogen Ion Source*)

被引:0
作者
Masaki S. [1 ]
Maeshiro K. [2 ]
Tsumori K. [1 ,3 ]
Wada M. [2 ]
机构
[1] Department of Fusion Science, SOKENDAI (The Graduate University for Advanced Studies), Toki, 509-5292, Gifu
[2] chool of Science and Engineering, Doshisha University, Kyotanabe,Kyoto
[3] National Institute for Fusion Science, Toki, 509-5292, Gifu
基金
日本学术振兴会;
关键词
filament material; Langmuir probe; negative hydrogen ion; negative ion extraction; plasma parameter;
D O I
10.1585/PFR.14.3401136
中图分类号
学科分类号
摘要
Plasma parameters were compared in the extraction region of a negative hydrogen (H-) ion source between the discharge sustained by tungsten (W) and tantalum (Ta) high temperature cathodes. A hydrogen plasma driven by the Ta filament showed lower electron temperature and higher ratio of positive ion saturation current to negative ion/electron saturation current than a plasma excited by the W filament. Plasma potential indicated different spatial distribution along the direction of H- ion extraction corresponding to the voltage biased on the plasma electrode. These results are correlated to the intensities of the H- ion extraction current. © 2019 The Japan Society of Plasma Science and Nuclear Fusion Research
引用
收藏
页码:1 / 5
页数:4
相关论文
共 15 条
  • [1] Bacal M., Wada M., Appl. Phys. Rev, 2, (2015)
  • [2] Schiesko L., Et al., Plasma Source Sci. Technol, 17, (2008)
  • [3] Belchenko Yu.I., Kuznetsov G.I., Grigoryev E.A., Rev. Sci. Instrum, 71, (2000)
  • [4] Sasao M., Et al., Appl. Ohys. Express, 11, (2018)
  • [5] Nishiura M., Et al., Rev. Sci. Instrum, 73, (2002)
  • [6] Bacal M., Wada M., AIP Conf. Proc, 1869, (2017)
  • [7] Masaki S., Maeshiro K., Tsumori K., Wada M., AIP Conf. Proc, 2052, (2018)
  • [8] Leung K.N., Bacal M., Rev. Sci. Instrum, 55, (1984)
  • [9] Leung K.N., Ehlers K.W., Bacal M., Rev. Sci. Instrum, 54, (1983)
  • [10] Takahashi H., Kasuya T., Wada M., Rev. Sci. Instrum, 77, (2006)