A new methodology for efficiency calibration of uncharacterized Ge detectors by using characterized Ge detectors

被引:1
|
作者
Barba-Lobo, A. [1 ,3 ]
Exposito-Suarez, V. M. [2 ]
Suarez-Navarro, J. A. [2 ]
Bolivar, J. P. [1 ]
机构
[1] Univ Huelva, Ctr Nat Resources Hlth & Environm RENSMA, Dept Integrated Sci, Radiat Phys & Environm Grp FRYMA, Huelva 21071, Spain
[2] CIEMAT, Dept Environm, Environm Radioact & Radiol Surveillance Unit URAyV, Ave Complutense 40, Madrid 28040, Spain
[3] Univ Gothenburg, Inst Clin Sci, Dept Med Radiat Sci, Sahlgrenska Acad, SE-41345 Gothenburg, Sweden
关键词
LabSOCS; Efficiency calibration; Gamma-ray spectrometry; Characterized Ge detectors; Uncharacterized; Natural radionuclides; GAMMA-SPECTROMETRY; HPGE DETECTORS; SIMULATION; SAMPLES; GEANT4; PB-210;
D O I
10.1016/j.radphyschem.2024.111763
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The measurement of gamma emitters natural radionuclides is a very relevant subject in environmental radioactivity in many fields. For this, a valid calibration based on the full-energy peak efficiency (FEPE) is essential, which can be carried out for gamma-ray spectrometry using Monte Carlo codes (Geant4, LabSOCS, MNCP, etc.) without needing a source preparation and with much less time consuming compared to experimental methodologies. Therefore, this work aims to develop a methodology for the FEPE determination of uncharacterized Ge detectors by using characterized Ge detectors with known FEPE. For this, a general relationship was found between the simulated FEPE (epsilon(sim)) for characterized Ge detectors by LabSOCS and the experimental one (epsilon(exp)) for uncharacterized Ge detectors obtained for a problem sample (phosphate rock (PR) in our case), where epsilon(sim) and epsilon(exp) were factorized using three correction factors: geometrical, photon self-absorption and true coincidence summing (TCS) effects. Thus, the epsilon(sim)/epsilon(exp) ratio (FEPER) was obtained for two couples of Ge detectors (2 characterized and 1 uncharacterized detectors), using 4 different cylindrical geometries (C) and 2 Marinelli (M) ones, and varying the sample thickness (h), and gamma energy (E-gamma) (from 46 keV (Pb-210) to 1765 keV (Bi-214)). The consistency obtained for the FEPERs for C geometries suggested a constant geometric factor, finding some deviations for M geometries only at E-gamma < 150 keV. Given a pair of detectors, the behavior of the FEPERs was found to be very similar for all geometries, and h at each specific E-gamma. Moreover, a constat relationship between the FEPERs of both detector couples versus E-gamma was found. Then, the influence of the TCS effects was also studied varying the distance between the geometry bottom and detector window. The developed methodology was also validated confirming the consistency of the FEPERs, which were found to be independent on the chemical composition and apparent density of the sample, supporting our theoretical hypothesis. Consequently, given that the FEPER was found to be independent on the sample type and h, using our developed methodology it is possible to obtain epsilon(exp) for any sample, geometry and h using the FEPER, previously obtained at each E-gamma for the sample selected for methodology development (PR in our case), and the epsilon(sim) that is obtained for the desired case.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Calibration of HPGe detectors using certified reference materials of natural origin
    Gerti Xhixha
    Matteo Alberi
    Marica Baldoncini
    Kozeta Bode
    Elida Bylyku
    Florinda Cfarku
    Ivan Callegari
    Fadil Hasani
    Sheldon Landsberger
    Fabio Mantovani
    Eva Rodriguez
    Ferat Shala
    Virginia Strati
    Merita Xhixha Kaçeli
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 1507 - 1517
  • [42] Three-dimensional position sensitivity in two-dimensionally segmented HP-Ge detectors
    Vetter, K
    Kuhn, A
    Deleplanque, MA
    Lee, IY
    Stephens, FS
    Schmid, GJ
    Beckedahl, D
    Blair, JJ
    Clark, RM
    Cromaz, M
    Diamond, RM
    Fallon, P
    Lane, GJ
    Kammeraad, JE
    Macchiavelli, AO
    Svensson, CE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 452 (1-2) : 223 - 238
  • [43] A simple methodology for characterization of germanium coaxial detectors by using Monte Carlo simulation and evolutionary algorithms
    Guerra, J. G.
    Rubiano, J. G.
    Winter, G.
    Guerra, A. G.
    Alonso, H.
    Arnedo, M. A.
    Tejera, A.
    Gil, J. M.
    Rodriguez, R.
    Martel, P.
    Bolivar, J. P.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2015, 149 : 8 - 18
  • [44] Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries
    Kumar, G. Anil
    Mazumdar, I.
    Gothe, D. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 611 (01) : 76 - 83
  • [45] CALIBRATION OF HPGE DETECTORS FOR ENVIRONMENTAL SAMPLES USING GEANT4 SIMULATION
    Nikolic, Jelena
    Rajacic, Milica
    Todorovic, Dragana
    Jankovic, Marija
    Sarap, Natasa
    Pantelic, Gordana
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 291 - 294
  • [46] A new model calculation of the peak efficiency for HPGe detectors used in assays of radioactive waste drums
    Stanga, D.
    Radu, D.
    Sima, O.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1418 - 1422
  • [47] Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples
    Baccouche, S.
    Al-Azmi, D.
    Karunakara, N.
    Trabelsi, A.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (01) : 227 - 232
  • [48] New algorithm for studying the effect of self attenuation factor on the efficiency of γ-rays detectors
    Badawi, Mohamed S.
    Gouda, Mona M.
    Nafee, Sherif S.
    El-Khatib, Ahmed M.
    El-Mallah, Ekram A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 696 : 164 - 170
  • [49] Monte Carlo calculations of coincidence-summing corrections for volume sources in gamma-ray spectrometry with Ge detectors
    García-Toraño, E
    Pozuelo, M
    Salvat, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 544 (03) : 577 - 583
  • [50] Calibration of 4π NaI(Tl) detectors with coincidence summing correction using new numerical procedure and ANGLE4 software
    Badawi, Mohamed S.
    Jovanovic, Slobodan I.
    Thabet, Abouzeid A.
    El-Khatib, Ahmed M.
    Dlabac, Aleksandar D.
    Salem, Bohaysa A.
    Gouda, Mona M.
    Mihaljevic, Nikola N.
    Almugren, Kholud S.
    Abbas, Mahmoud I.
    AIP ADVANCES, 2017, 7 (03)