A new methodology for efficiency calibration of uncharacterized Ge detectors by using characterized Ge detectors

被引:1
|
作者
Barba-Lobo, A. [1 ,3 ]
Exposito-Suarez, V. M. [2 ]
Suarez-Navarro, J. A. [2 ]
Bolivar, J. P. [1 ]
机构
[1] Univ Huelva, Ctr Nat Resources Hlth & Environm RENSMA, Dept Integrated Sci, Radiat Phys & Environm Grp FRYMA, Huelva 21071, Spain
[2] CIEMAT, Dept Environm, Environm Radioact & Radiol Surveillance Unit URAyV, Ave Complutense 40, Madrid 28040, Spain
[3] Univ Gothenburg, Inst Clin Sci, Dept Med Radiat Sci, Sahlgrenska Acad, SE-41345 Gothenburg, Sweden
关键词
LabSOCS; Efficiency calibration; Gamma-ray spectrometry; Characterized Ge detectors; Uncharacterized; Natural radionuclides; GAMMA-SPECTROMETRY; HPGE DETECTORS; SIMULATION; SAMPLES; GEANT4; PB-210;
D O I
10.1016/j.radphyschem.2024.111763
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The measurement of gamma emitters natural radionuclides is a very relevant subject in environmental radioactivity in many fields. For this, a valid calibration based on the full-energy peak efficiency (FEPE) is essential, which can be carried out for gamma-ray spectrometry using Monte Carlo codes (Geant4, LabSOCS, MNCP, etc.) without needing a source preparation and with much less time consuming compared to experimental methodologies. Therefore, this work aims to develop a methodology for the FEPE determination of uncharacterized Ge detectors by using characterized Ge detectors with known FEPE. For this, a general relationship was found between the simulated FEPE (epsilon(sim)) for characterized Ge detectors by LabSOCS and the experimental one (epsilon(exp)) for uncharacterized Ge detectors obtained for a problem sample (phosphate rock (PR) in our case), where epsilon(sim) and epsilon(exp) were factorized using three correction factors: geometrical, photon self-absorption and true coincidence summing (TCS) effects. Thus, the epsilon(sim)/epsilon(exp) ratio (FEPER) was obtained for two couples of Ge detectors (2 characterized and 1 uncharacterized detectors), using 4 different cylindrical geometries (C) and 2 Marinelli (M) ones, and varying the sample thickness (h), and gamma energy (E-gamma) (from 46 keV (Pb-210) to 1765 keV (Bi-214)). The consistency obtained for the FEPERs for C geometries suggested a constant geometric factor, finding some deviations for M geometries only at E-gamma < 150 keV. Given a pair of detectors, the behavior of the FEPERs was found to be very similar for all geometries, and h at each specific E-gamma. Moreover, a constat relationship between the FEPERs of both detector couples versus E-gamma was found. Then, the influence of the TCS effects was also studied varying the distance between the geometry bottom and detector window. The developed methodology was also validated confirming the consistency of the FEPERs, which were found to be independent on the chemical composition and apparent density of the sample, supporting our theoretical hypothesis. Consequently, given that the FEPER was found to be independent on the sample type and h, using our developed methodology it is possible to obtain epsilon(exp) for any sample, geometry and h using the FEPER, previously obtained at each E-gamma for the sample selected for methodology development (PR in our case), and the epsilon(sim) that is obtained for the desired case.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Monte Carlo calculation of the efficiency calibration curve for HPGe detectors
    Bhattacharya, Tam
    Nagaiah, N.
    Reddy, B. Ram Mohan
    Sharma, P. K.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2018, 56 (08) : 628 - 630
  • [32] A fitting algorithm based on simulated annealing techniques for efficiency calibration of HPGe detectors using different mathematical functions
    Hurtado, S.
    Garcia-Leon, M.
    Garcia-Tenorio, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (03) : 362 - 367
  • [33] Study of equivalent efficiency calibration method for radioactive gas source measured on HPGe detectors
    Yu, Gongshuo
    Li, Xuesong
    Bai, Tao
    He, Xiaobing
    Fan, Jinlong
    Shang, Jianbo
    Shi, Quanlin
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2020, 57 (05) : 599 - 606
  • [34] Calibration of HPGe detectors using certified reference materials of natural origin
    Xhixha, Gerti
    Alberi, Matteo
    Baldoncini, Marica
    Bode, Kozeta
    Bylyku, Elida
    Cfarku, Florinda
    Callegari, Ivan
    Hasani, Fadil
    Landsberger, Sheldon
    Mantovani, Fabio
    Rodriguez, Eva
    Shala, Ferat
    Strati, Virginia
    Kaceli, Merita Xhixha
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (02) : 1507 - 1517
  • [35] Simplified efficiency calibration methods for scintillation detectors used in nuclear remediation
    Golovko, Victor V.
    JOURNAL OF CLEANER PRODUCTION, 2024, 478
  • [36] Efficiency calibration of infrared single photon detectors by means of twin photons
    Feng, Yu
    Zhang, Yangyang
    Zhao, Pengyu
    AOPC 2017: SPACE OPTICS AND EARTH IMAGING AND SPACE NAVIGATION, 2017, 10463
  • [37] Efficiency calibration of an extended-range Ge detector by a detailed Monte Carlo simulation
    Peyres, V.
    Garcia-Torano, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) : 296 - 298
  • [38] A GENERALIZED MATHEMATICAL MODEL FOR EFFICIENCY CALIBRATION OF GAMMA DETECTORS Application to Practical Cases
    Mihaljevic, Nikola N.
    Jovanovic, Slobodan I.
    Dlabac, Aleksandar D.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2019, 34 (01) : 34 - 46
  • [39] Validation of analytical formula for the efficiency calibration of gamma detectors using coaxial and off-axis extended sources
    Hamzawy, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 618 (1-3) : 216 - 222
  • [40] CREPT-MCNP code for efficiency calibration of HPGe detectors with the representative point method
    Saegusa, Jun
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 774 - 779