A new methodology for efficiency calibration of uncharacterized Ge detectors by using characterized Ge detectors

被引:1
|
作者
Barba-Lobo, A. [1 ,3 ]
Exposito-Suarez, V. M. [2 ]
Suarez-Navarro, J. A. [2 ]
Bolivar, J. P. [1 ]
机构
[1] Univ Huelva, Ctr Nat Resources Hlth & Environm RENSMA, Dept Integrated Sci, Radiat Phys & Environm Grp FRYMA, Huelva 21071, Spain
[2] CIEMAT, Dept Environm, Environm Radioact & Radiol Surveillance Unit URAyV, Ave Complutense 40, Madrid 28040, Spain
[3] Univ Gothenburg, Inst Clin Sci, Dept Med Radiat Sci, Sahlgrenska Acad, SE-41345 Gothenburg, Sweden
关键词
LabSOCS; Efficiency calibration; Gamma-ray spectrometry; Characterized Ge detectors; Uncharacterized; Natural radionuclides; GAMMA-SPECTROMETRY; HPGE DETECTORS; SIMULATION; SAMPLES; GEANT4; PB-210;
D O I
10.1016/j.radphyschem.2024.111763
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The measurement of gamma emitters natural radionuclides is a very relevant subject in environmental radioactivity in many fields. For this, a valid calibration based on the full-energy peak efficiency (FEPE) is essential, which can be carried out for gamma-ray spectrometry using Monte Carlo codes (Geant4, LabSOCS, MNCP, etc.) without needing a source preparation and with much less time consuming compared to experimental methodologies. Therefore, this work aims to develop a methodology for the FEPE determination of uncharacterized Ge detectors by using characterized Ge detectors with known FEPE. For this, a general relationship was found between the simulated FEPE (epsilon(sim)) for characterized Ge detectors by LabSOCS and the experimental one (epsilon(exp)) for uncharacterized Ge detectors obtained for a problem sample (phosphate rock (PR) in our case), where epsilon(sim) and epsilon(exp) were factorized using three correction factors: geometrical, photon self-absorption and true coincidence summing (TCS) effects. Thus, the epsilon(sim)/epsilon(exp) ratio (FEPER) was obtained for two couples of Ge detectors (2 characterized and 1 uncharacterized detectors), using 4 different cylindrical geometries (C) and 2 Marinelli (M) ones, and varying the sample thickness (h), and gamma energy (E-gamma) (from 46 keV (Pb-210) to 1765 keV (Bi-214)). The consistency obtained for the FEPERs for C geometries suggested a constant geometric factor, finding some deviations for M geometries only at E-gamma < 150 keV. Given a pair of detectors, the behavior of the FEPERs was found to be very similar for all geometries, and h at each specific E-gamma. Moreover, a constat relationship between the FEPERs of both detector couples versus E-gamma was found. Then, the influence of the TCS effects was also studied varying the distance between the geometry bottom and detector window. The developed methodology was also validated confirming the consistency of the FEPERs, which were found to be independent on the chemical composition and apparent density of the sample, supporting our theoretical hypothesis. Consequently, given that the FEPER was found to be independent on the sample type and h, using our developed methodology it is possible to obtain epsilon(exp) for any sample, geometry and h using the FEPER, previously obtained at each E-gamma for the sample selected for methodology development (PR in our case), and the epsilon(sim) that is obtained for the desired case.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A simple method for efficiency calibration of HPGe detectors in γ-spectrometric measurements
    Pérez-Moreno, JP
    Bolívar, JP
    García-Tenorio, R
    Miguel, ES
    Aguado, JL
    Mas, JL
    Vaca, F
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 437 - 438
  • [22] Pulse shape discrimination performance of inverted coaxial Ge detectors
    Domula, A.
    Hult, M.
    Kermaidic, Y.
    Marissens, G.
    Schwingenheuer, B.
    Wester, T.
    Zuber, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 891 : 106 - 110
  • [23] Characterization of 30 76Ge enriched Broad Energy Ge detectors for GERDA Phase II
    Agostini, M.
    Bakalyarov, A. M.
    Andreotti, E.
    Balata, M.
    Barabanov, I.
    Baudis, L.
    Barros, N.
    Bauer, C.
    Bellotti, E.
    Belogurov, S.
    Benato, G.
    Bettini, A.
    Bezrukov, L.
    Bode, T.
    Borowicz, D.
    Brudanin, V.
    Brugnera, R.
    Budjas, D.
    Caldwell, A.
    Cattadori, C.
    Chernogorov, A.
    D'Andrea, V.
    Demidova, E. V.
    Di Marco, N.
    Domula, A.
    Doroshkevich, E.
    Egorov, V.
    Falkenstein, R.
    Freund, K.
    Gangapshev, A.
    Garfagnini, A.
    Gooch, C.
    Grabmayr, P.
    Gurentsov, V.
    Gusev, K.
    Hakenmueller, J.
    Hegai, A.
    Heisel, M.
    Hemmer, S.
    Hiller, R.
    Hofmann, W.
    Hult, M.
    Inzhechik, L. V.
    Csathy, J. Janicsko
    Jochum, J.
    Junker, M.
    Kazalov, V.
    Kermaidic, Y.
    Kihm, T.
    Kirpichnikov, I. V.
    EUROPEAN PHYSICAL JOURNAL C, 2019, 79 (11):
  • [24] Detection efficiency calibration for an array of fourteen HPGe detectors
    Park, S. Y.
    Hahn, K. I.
    Kang, W. G.
    Kazalov, V.
    Kim, G. W.
    Kim, Y. D.
    Lee, E. K.
    Lee, M. H.
    Leonard, D. S.
    Sala, E.
    So, J. H.
    Yoon, S. C.
    APPLIED RADIATION AND ISOTOPES, 2023, 193
  • [25] An upgraded lab-based method to determine natural γ-ray emitters in NORM samples by using Ge detectors
    Barba-Lobo, A.
    Mosqueda, F.
    Bolivar, J. P.
    MEASUREMENT, 2021, 186
  • [26] An upgraded lab-based method to determine natural γ-ray emitters in NORM samples by using Ge detectors
    Barba-Lobo A.
    Mosqueda F.
    Bolívar J.P.
    Measurement: Journal of the International Measurement Confederation, 2021, 186
  • [27] Determination of full-energy peak and total efficiency functions for Ge-detectors by iteration calculation using a mixed radionuclide source
    Ishizu, H.
    Yamada, T.
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 163 - 166
  • [28] Accounting for incomplete charge collection in Monte Carlo simulations of the efficiency of well-type Ge-detectors
    Hernández, F
    El-Daoushy, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 498 (1-3) : 340 - 351
  • [29] Transfer of the efficiency calibration of Germanium gamma-ray detectors using the GESPECOR software
    Sima, O
    Arnold, D
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 71 - 75
  • [30] From Ge(Li) detectors to gamma-ray tracking arrays - 50 years of gamma spectroscopy with germanium detectors
    Eberth, J.
    Simpson, J.
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, VOL 60, NO 2, 2008, 60 (02): : 283 - 337