Supplementary comparison on digital multimeter

被引:0
|
作者
Ahmad S. [1 ]
John T. [1 ]
Negi P.S. [1 ]
Budovsky I. [2 ]
Marais L. [2 ]
Leones S.P.B. [3 ]
Hassan N.A. [4 ]
Choon T.S. [5 ]
Yang S. [6 ]
Prinsloo P.J. [7 ]
Ma'ruf A. [8 ]
Tanarom J. [9 ]
Rujirat N. [9 ]
Linh P.T.K. [10 ]
Jargal A. [11 ]
Panga J. [12 ]
Tadros N.N. [13 ]
Sayed R. [13 ]
Alanka R.D.M. [14 ]
Konkanov M. [15 ]
Nurlan S. [15 ]
Sehweil I. [16 ]
Flaifel M. [16 ]
Zaher S.A. [17 ]
机构
[1] National Physical Laboratory India, NPLI
[2] National Measurement Institute of Australia, NMIA
[3] National Metrology Laboratory of Philippines, NML-ITDI
[4] National Measurement Institute of Malaysia, NMIM
[5] National Metrology Center, NMC A*STAR
[6] Standard and Calibration Laboratory, SCL
[7] National Metrology Institute South Africa, NMISA
[8] Kalibrasi, Instrumentasi dan Metrologi Indonesia, KIM-LIPI
[9] National Institute of Metrology of Thailand, NIMT
[10] Vietnam Metrology Institute, VMI
[11] Mongolian Agency for Standardization and Metrology, MASM
[12] National Institute of Standards and Industrial Technology of Papua New Guinea, NISIT
[13] National Institute for Standards of Egypt, NIS
[14] Standard and Services Department of Sri Lanka, Measurement Units, MUSSD
[15] Kazakhstan Institute of Metrology, KazInMetr
[16] Jordan National Metrology Institute, JNMI
关键词
Compendex;
D O I
10.1088/0026-1394/60/1A/01006
中图分类号
学科分类号
摘要
Main text A measurement comparison of DC voltage, DC current, DC resistance, AC voltage and AC current has been carried out among seventeen national metrology laboratories with the travelling standards 6½ digit multimeter (Fluke model 8846A) as Loop A, Loop B and Loop C for the nominal values of the measured parameters DC voltage (100 mV, 1 V, 10 V, -10 V, 100 V and 1000 V), DC current (10 mA and 1 A), DC resistance (100 ω, 1 kω and 10 kω (using 4-wire), AC voltage (100 mV, 1 V, 10 V, 100 V and 700 V at 40 Hz and 1 kHz) and AC current (10 mA and 1 A at 40 Hz and 1 kHz) for establishing the degrees of equivalence among the participating NMIs. This is the final report on the comparison. The report presents the combined results (Loop A, Loop B and Loop C), represented by corrections in measured parameters and the corresponding expanded uncertainties. The combined results from the three loops have been used to calculate the Supplementary Comparison Reference Values, degrees of equivalence di and corresponding uncertainties u(di) of each laboratory that participated in the comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). © 2023 BIPM & IOP Publishing Ltd.
引用
收藏
相关论文
共 50 条