Development of Overhead Transmission Line Monitoring Device for FDLR Calculation

被引:0
|
作者
Sik-Kim C. [1 ]
Kim Y.-H. [2 ]
Keum E.-Y. [3 ]
机构
[1] Transmission & Substation Lab., KEPCO Research Institute
[2] Cheryong Industrial co., Ltd
关键词
Energy Harvesting; FDLR; Monitoring System; Overhead Transmission Line; Sag; Tilt sensor;
D O I
10.5370/KIEE.2023.72.4.547
中图分类号
学科分类号
摘要
As NDC(Nationally Determined Contributions) was raised in the Paris Agreement in 2015, power generation using renewable energy that can minimize carbon use has become a more important task. However if a new renewable power generation source is unilaterally connected to the grid, the transmission capacity increases than the current capacity and due to the nature of new and renewable energy, the fluctuation range of power generation is larger which can increase system instability. Therefore efficient transmission line operation is required. Moreover it is difficult to actually implement the expansion of transmission capacity because social acceptance is not good. Therefore in order to solve this problem real-time dynamic transmission capacity (Forecasted Dynamic Line Rating) calculation technology that can maximize the use of transmission capacity in existing lines is required. This paper describes the development of a system that can monitor the surrounding environment of transmission towers and thermal rating data of overhead lines in real time to implement the calculation algorithm. Copyright © The Korean Institute of Electrical Engineers.
引用
收藏
页码:547 / 552
页数:5
相关论文
共 50 条
  • [31] Lightning overvoltage analysis and calculation of 330kV overhead transmission line
    Zhang Xiubin
    Wen Dingjun
    Sun Yaming
    Chen Honggang
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 1588 - 1591
  • [32] Monitoring of overhead transmission lines
    Wilson, M. S.
    Hurlebaus, S.
    STRUCTURAL HEALTH MONITORING 2007: QUANTIFICATION, VALIDATION, AND IMPLEMENTATION, VOLS 1 AND 2, 2007, : 443 - 450
  • [33] Development of Optical Fiber Sensors Based on Brillouin Scattering and FBG for On-Line Monitoring in Overhead Transmission Lines
    Luo, Jianbin
    Hao, Yanpeng
    Ye, Qing
    Hao, Yunqi
    Li, Licheng
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2013, 31 (10) : 1559 - 1565
  • [34] Overhead Line Monitoring Model Based on the Long-distance Transmission Network
    Ouyan Jiankun
    Zhou Churui
    PROCEEDINGS OF THE 2013 8TH INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE & EDUCATION (ICCSE 2013), 2013, : 76 - 79
  • [35] Discussion on Real-time Monitoring Method of Overhead Transmission Line Icing
    Liu, Ran
    Jiao, Zheng-Chang
    Li, Dong-Xue
    2015 INTERNATIONAL CONFERENCE ON ENVIRONMENT, MANUFACTURING INDUSTRY AND ECONOMIC DEVELOPMENT, (EMIED 2015), 2015, : 246 - 250
  • [36] Robot Delay-Tolerant Sensor Network for Overhead Transmission Line Monitoring
    Fan, Fei
    Wu, Gongping
    Wang, Man
    Cao, Qi
    Yang, Song
    APPLIED SCIENCES-BASEL, 2018, 8 (06):
  • [37] On Wireless Sensors Communication for Overhead Transmission Line Monitoring in Power Delivery Systems
    Hung, K. S.
    Lee, W. K.
    Li, V. O. K.
    Lui, K. S.
    Pong, P. W. T.
    Wong, K. K. Y.
    Yang, G. H.
    Zhong, J.
    2010 IEEE 1ST INTERNATIONAL CONFERENCE ON SMART GRID COMMUNICATIONS (SMARTGRIDCOMM), 2010, : 309 - 314
  • [38] Fault tolerance mechanism for sensors monitoring overhead transmission line in smart grid
    Tang X.
    Guo S.
    Qi F.
    Tang, Xiaoxuan (xxtang@bupt.edu.cn), 2016, Science Press (38): : 700 - 706
  • [39] Real-Time Overhead Transmission-Line Monitoring for Dynamic Rating
    Douglass, Dale
    Chisholm, William
    Davidson, Glenn
    Grant, Ian
    Lindsey, Keith
    Lancaster, Mark
    Lawry, Dan
    McCarthy, Tom
    Nascimento, Carlos
    Pasha, Mohammad
    Reding, Jerry
    Seppa, Tapani
    Toth, Janos
    Waltz, Peter
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (03) : 921 - 927
  • [40] WSN-Based Efficient Monitoring for Overhead Transmission Line in Smart Grid
    Li, Miao
    Chi, Xiao-Bo
    Jia, Xin-Chun
    Zhang, Jun-Li
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 8485 - 8489