Development of Overhead Transmission Line Monitoring Device for FDLR Calculation

被引:0
|
作者
Sik-Kim C. [1 ]
Kim Y.-H. [2 ]
Keum E.-Y. [3 ]
机构
[1] Transmission & Substation Lab., KEPCO Research Institute
[2] Cheryong Industrial co., Ltd
关键词
Energy Harvesting; FDLR; Monitoring System; Overhead Transmission Line; Sag; Tilt sensor;
D O I
10.5370/KIEE.2023.72.4.547
中图分类号
学科分类号
摘要
As NDC(Nationally Determined Contributions) was raised in the Paris Agreement in 2015, power generation using renewable energy that can minimize carbon use has become a more important task. However if a new renewable power generation source is unilaterally connected to the grid, the transmission capacity increases than the current capacity and due to the nature of new and renewable energy, the fluctuation range of power generation is larger which can increase system instability. Therefore efficient transmission line operation is required. Moreover it is difficult to actually implement the expansion of transmission capacity because social acceptance is not good. Therefore in order to solve this problem real-time dynamic transmission capacity (Forecasted Dynamic Line Rating) calculation technology that can maximize the use of transmission capacity in existing lines is required. This paper describes the development of a system that can monitor the surrounding environment of transmission towers and thermal rating data of overhead lines in real time to implement the calculation algorithm. Copyright © The Korean Institute of Electrical Engineers.
引用
收藏
页码:547 / 552
页数:5
相关论文
共 50 条
  • [21] Measurement and monitoring of overhead transmission line sag in smart grid: A review
    Mahin, Ayman Uddin
    Islam, Shama Naz
    Ahmed, Fabliha
    Hossain, Md Farhad
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (01) : 1 - 18
  • [22] A Novel Fault Monitoring Mechanism on Overhead Transmission Line in Power Grid
    Korde, Neha
    Bhagat, Narendra
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL (I2C2), 2017,
  • [23] Study on vibration monitoring and anti-vibration of overhead transmission line
    Yin, Weihua
    Lin, Li
    NONLINEAR ENGINEERING - MODELING AND APPLICATION, 2021, 10 (01): : 395 - 403
  • [24] Phi-OTDR Based On-Line Monitoring of Overhead Power Transmission Line
    Ding, Zhe-Wen
    Zhang, Xu-Ping
    Zou, Ning-Mu
    Xiong, Fei
    Song, Jin-Yu
    Fang, Xing
    Wang, Feng
    Zhang, Yi-Xin
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (15) : 5163 - 5169
  • [25] On-line monitoring of sag in overhead transmission lines with leveled spans
    Ramachandran, Poorani
    Vittal, Vijay
    2006 38TH ANNUAL NORTH AMERICAN POWER SYMPOSIUM, NAPS-2006 PROCEEDINGS, 2006, : 405 - +
  • [26] Universal wireless powered terminals for robust overhead transmission line monitoring
    Cai, Changsong
    Wang, Junhua
    Jing, Hang
    Zhang, Fan
    Zhang, Pengcheng
    Fang, Zhijian
    Zhou, Ying-Guo
    IET POWER ELECTRONICS, 2019, 12 (14) : 3739 - 3748
  • [28] Calculation method and distribution laws of electric field on surface of overhead transmission line
    Yang, Yong
    Liu, Yuanqing
    Wu, Guifang
    Lu, Jiayu
    Ju, Yong
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (05): : 1644 - 1650
  • [29] Calculation of steady state of multichain overhead power transmission line in phase coordinates
    Goldstein, Valery
    Vedernikov, Alexander
    Shishkov, Evgeny
    Kolcun, Michal
    PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013), 2013, : 145 - 148
  • [30] Overhead Transmission Line Sag, Tension and Length Calculation using Affine Arithmetic
    Abebe, Yoseph Mekonnen
    Rao, P. Mallikarjuna
    2015 IEEE POWER, COMMUNICATION AND INFORMATION TECHNOLOGY CONFERENCE (PCITC-2015), 2015, : 211 - 216