A tumor-targeting two-photon fluorescent probe with a far-red to NIR emission for imaging basal hypochlorite in cancer cells and tumor

被引:2
|
作者
Mao, Guo-Jiang [1 ]
Zhang, Shu-Yu [1 ]
Yang, Tian-Tian [1 ]
Zhu, Baosong [3 ]
Sun, Xue-Yu [2 ]
Wang, Qian-Qian [2 ]
Zhang, Guisheng [1 ]
机构
[1] Henan Normal Univ, Collaborat Innovat Ctr Henan Prov Green Mfg Fine C, Henan Key Lab Organ Funct Mol & Drug Innovat, Sch Chem & Chem Engn,Minist Educ,Key Lab Green Che, Xinxiang 453007, Peoples R China
[2] Xinxiang Med Univ, Dept Pharm, Henan Int Joint Lab Cardiovasc Remodeling & Drug I, Xinxiang Key Lab Vasc Remodeling Intervent & Mol T, 601 Jinsui Rd, Xinxiang 453003, Peoples R China
[3] Nanjing Univ Chinese Med, Suzhou TCM Hosp Affiliated, Dept Gen Surg, Suzhou, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Two-photon fluorescent probe; Hypochlorite; Tumor-targeting; Far-red to NIR emission; Cancer cells; ACID; MITOCHONDRIA; LYSOSOME; HOCL; OXIDANTS; TISSUES; STRESS; HCLO;
D O I
10.1016/j.talanta.2024.126436
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cancer cells have a high abundance of hypochlorite compared to normal cells, which can be used as the biomarker for imaging cancer cells and tumor. Developing the tumor-targeting fluorescent probe suitable for imaging hypochlorite in vivo is urgently demanded. In this article, based on xanthene dye with a two-photon excited far-red to NIR emission, a tumor-targeting two-photon fluorescent probe (Biotin-HClO) for imaging basal hypochlorite in cancer cells and tumor was developed. For ClO- , Biotin-HClO (20.0 mu M) has a linear response range from 15.0 x 10- 8 to 1.1 x 10-5 M with a high selectivity and a high sensitivity, a good detection limit of 50 nM and a 550-fold fluorescence enhancement with high signal-to-noise ratio (20 mM PBS buffer solution with 50 % DMF; pH = 7.4; Rex = 605 nm; Rem = 635 nm). Morover, Biotin-HClO exhibited excellent performance in monitoring exogenous and endogenous ClO- in cells, and has an outstanding tumor-targeting ability. Subsequently, Biotin-HClO has been applied for imaging ClO- in 4T1 tumor tissue to distinguish from normal tissue. Furthermore, Biotin-HClO was successfully employed for high-contrast imaging 4T1 tumor in mouse based on its tumor-targeting ability. All these results proved that Biotin-HClO is a useful analytical tool to detect ClO- and image tumor in vivo.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A tumor-targeting fluorescent probe for ratiometric imaging of pH and improving PDT/PTT synergistic therapy
    Gu, Qing-Song
    Li, Ting
    Wang, Wen-Xin
    Wang, Zhi-Qing
    Liu, Qiao-Rong
    Mao, Guo-Jiang
    Li, Yongfei
    Li, Chun-Yan
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 393
  • [22] A novel two-photon fluorescent probe with long-wavelength emission for monitoring HClO in living cells and tissues
    Gong, Yi-Jun
    Lv, Meng-Ke
    Zhang, Ming-Lu
    Kong, Zhen-Zhen
    Mao, Guo-Jiang
    TALANTA, 2019, 192 : 128 - 134
  • [23] A novel visual and far-red fluorescent dual-channel probe for the rapid and sensitive detection of hypochlorite in aqueous solution and living cells
    Shu, Wei
    Yan, Liangguo
    Wang, Zuokai
    Liu, Jin
    Zhang, Shan
    Liu, Caiyun
    Zhu, Baocun
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1130 - 1136
  • [24] Far-Red and Near-IR AIE-Active Fluorescent Organic Nanoprobes with Enhanced Tumor-Targeting Efficacy: Shape-Specific Effects
    Shao, Andong
    Xie, Yongshu
    Zhu, Shaojia
    Guo, Zhiqian
    Zhu, Shiqin
    Guo, Jin
    Shi, Ping
    James, Tony D.
    Tian, He
    Zhu, Wei-Hong
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2015, 54 (25) : 7275 - 7280
  • [25] A two-photon fluorescent probe for ratiometric imaging of endogenous hypochlorous acid in live cells and tissues
    Jun, Yong Woong
    Sarkar, Sourav
    Singha, Subhankar
    Reo, Ye Jin
    Kim, Hye Rim
    Kim, Jong-Jin
    Chang, Young-Tae
    Ahn, Kyo Han
    CHEMICAL COMMUNICATIONS, 2017, 53 (78) : 10800 - 10803
  • [26] A highly selective and ultrasensitive ratiometric far-red fluorescent probe for imaging endogenous peroxynitrite in living cells
    Zhu, Baocun
    Wu, Liu
    Wang, Yawei
    Zhang, Meng
    Zhao, Ziyang
    Liu, Caiyun
    Wang, Zuokai
    Duan, Qingxia
    Jia, Pan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 259 : 797 - 802
  • [27] A ratiometric mitochondria-targeting two-photon fluorescent probe for imaging of nitric oxide in vivo
    Zhu, Xinyue
    Chen, Jin-Quan
    Ma, Chen
    Liu, Xiaoyan
    Cao, Xiao-Ping
    Zhang, Haixia
    ANALYST, 2017, 142 (24) : 4623 - 4628
  • [28] A red emitting two-photon fluorescent probe for dynamic imaging of redox balance meditated by a superoxide anion and GSH in living cells and tissues
    Liu, Hong-Wen
    Zhu, Xiaoyan
    Zhang, Jing
    Zhang, Xiao-Bing
    Tan, Weihong
    ANALYST, 2016, 141 (20) : 5893 - 5899
  • [29] Two-photon active fluorescent indicator for detecting NADH dynamics in live cells and tumor tissue
    Podder, Arup
    Thirumalaivasan, Natesan
    Chao, Yu Kai
    Kukutla, Prasanna
    Wu, Shu-Pao
    Bhuniya, Sankarprasad
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 324
  • [30] A ratiometric two-photon fluorescent probe for fluoride ion imaging in living cells and zebrafish
    Hu, Wei
    Zeng, Lingyu
    Wang, Yanying
    Liu, Zhihong
    Ye, Xiaoxue
    Li, Chunya
    ANALYST, 2016, 141 (18) : 5450 - 5455