A selective analysis of sulfamethoxazole-Trimethoprim in tablet formulations using graphene oxide-zinc oxide quantum dots based nanocomposite modified glassy carbon electrode

被引:10
作者
Kumar, P. Senthil [1 ,2 ]
Padmalaya, G. [1 ,2 ]
Elavarasan, N. [1 ,2 ]
Sreeja, B. S. [2 ,3 ]
机构
[1] Sri Sivasubramaniya Nadar Coll Engn, Dept Chem Engn, Kalavakkam 603110, Tamil Nadu, India
[2] Sri Sivasubramaniya Nadar Coll Engn, Ctr Excellence Water Res CEWAR, Kalavakkam 603110, Tamil Nadu, India
[3] Sri Sivasubramaniya Nadar Coll Engn, Dept Elect & Commun Engn, Kalavakkam 603110, Tamil Nadu, India
关键词
Graphene oxide; ZnO QDs; Sulfamethoxazole; Trimethoprim; Electrochemical sensor; GO-ZnO QDs nanocomposite; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL SENSORS; PASTE ELECTRODE; UV-DETECTION; WASTE-WATER; ANTIBIOTICS; NANOTUBES; URINE; PARACETAMOL; CAPTOPRIL;
D O I
10.1016/j.chemosphere.2023.138814
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, simultaneous analysis on electrochemical detection of SMX and TMP in tablet formulation has been made using graphene oxide (GO) and ZnO QDs (GO-ZnO QDs) based nanocomposite modified glassy carbon electrode (GCE). The functional group presence was observed using FTIR study. The electrochemical charac-terization for GO, ZnO QDs and GO-ZnO QDs was studied using cyclic voltammetry using [Fe(CN)6]3-medium. In order to estimate the electrochemical redox behavior of SMX and TMP from tablet, the developed electrodes GO/ GCE, ZnO QDs/GCE and GO-ZnO QDs/GCE are initially tested for electrochemical activity towards the SMX tablet in BR pH 7 medium. Later their electrochemical sensing has been monitored using square wave voltam-metry (SWV). On observing the characteristic behavior of developed electrodes, GO/GCE exhibited detection potential of +0.48 V for SMX and +1.37 V for TMP whereas, ZnO QDs/GCE with +0.78V for SMX and for TMP 1.01 V respectively. Similarly, for GO-ZnO QDs/GCE, its 0.45 V for SMX and 1.11 V for TMP are observed using cyclic voltammetry. The obtained potential results on detecting SMX and TMP are in good agreement with previous results. Under optimized conditions, the response has been monitored with linear concentration range 50 mu g/L to 300 mu g/L for GO/GCE, ZnO QDs/GCE and GO-ZnO QDs/GCE in SMX tablet formulations. Their detection limits for the individual detection using GO-ZnO/GCE for SMX and TMP are found to be 0.252 ng/L and 19.10 mu g/L and for GO/GCE it was 0.252 pg/L and 2.059 ng/L respectively. It was observed that ZnO QDs/ GCE could not provide the electrochemical sensing towards SMX and TMP which may be due to the ZnO QPs can act as a blocking layer impeding the electron transfer process. Thus, the sensor performance lead to promising biomedical applications in real-time monitoring on evaluating selective analysis with SMX and TMP in tablet formulations.
引用
收藏
页数:14
相关论文
共 54 条
[1]   Simultaneous and sensitive detection of acetaminophen and valacyclovir based on two dimensional graphene nanosheets [J].
Adhikari, Bal-Ram ;
Govindhan, Maduraiveeran ;
Schraft, Heidi ;
Chen, Aicheng .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 780 :241-248
[2]  
Al-Fandi M., 2015, IOP Conference Series: Materials Science and Engineering, V92, DOI [10.1088/1757-899x/92/1/012009, 10.1088/1757-899X/92/1/012009]
[3]   Preparation and characterization of GO-ZnO nanocomposite for UV detection application [J].
Alamdari, Sanaz ;
Ghamsari, Morteza Sasani ;
Afarideh, Hosein ;
Mohammadi, Aghil ;
Geranmayeh, Shayan ;
Tafreshi, Majid Jafar ;
Ehsani, Mohammad Hosein ;
Ara, Mohammad Hosein Majles .
OPTICAL MATERIALS, 2019, 92 :243-250
[4]   Versatile Graphene oxide decorated by star shaped Zinc oxide nanocomposites with superior adsorption capacity and antimicrobial activity [J].
Archana, S. ;
Kumar, K. Yogesh ;
Jayanna, B. K. ;
Olivera, Sharon ;
Anand, A. ;
Prashanth, M. K. ;
Muralidhara, H. B. .
JOURNAL OF SCIENCE-ADVANCED MATERIALS AND DEVICES, 2018, 3 (02) :167-174
[5]   Simultaneous voltammetric determination of tyrosine and paracetamol using a carbon nanotube-graphene nanosheet nanocomposite modified electrode in human blood serum and pharmaceuticals [J].
Arvand, Majid ;
Gholizadeh, Tahereh M. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 103 :84-93
[6]   Recent advances in ZnO nanostructure-based electrochemical sensors and biosensors [J].
Beitollahi, Hadi ;
Tajik, Somayeh ;
Garkani Nejad, Fariba ;
Safaei, Mohadeseh .
JOURNAL OF MATERIALS CHEMISTRY B, 2020, 8 (27) :5826-5844
[7]   Electrocatalytic determination of captopril using a modified carbon nanotube paste electrode: Application to determination of captopril in pharmaceutical and biological samples [J].
Beitollahi, Hadi ;
Taher, Mohammad Ali ;
Ahmadipour, Malihe ;
Hosseinzadeh, Rahman .
MEASUREMENT, 2014, 47 :770-776
[8]   Simultaneous oxidative determination of antibacterial drugs in aqueous solutions using an electrode modified with MWCNTs decorated with Fe3O4 nanoparticles [J].
Bhengo, T. ;
Moyo, M. ;
Shumba, M. ;
Okonkwo, O. J. .
NEW JOURNAL OF CHEMISTRY, 2018, 42 (07) :5014-5023
[9]   Determination of sulfamethoxazole in foods based on CeO2/chitosan nanocomposite-modified electrodes [J].
Cai, Meizhi ;
Zhu, Lei ;
Ding, Yaping ;
Wang, Junxia ;
Li, Jianshuang ;
Du, Xiaoyan .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (08) :2623-2627
[10]   Effect of combined chemical and electrochemical reduction of graphene oxide on morphology and structure of electrodeposited ZnO [J].
Cembrero, J. ;
Pruna, A. ;
Pullini, D. ;
Busquets-Mataix, D. .
CERAMICS INTERNATIONAL, 2014, 40 (07) :10351-10357