Acupuncture efficacy study using electromyographic signals

被引:0
作者
Sabri Y. [1 ,2 ,3 ]
Lamzabi S. [1 ,2 ,3 ]
Siham A. [1 ,2 ,3 ]
Maizate A. [1 ,2 ,3 ]
机构
[1] Laboratory of Innovation in Management and Engineering for Enterprise (LIMIE), ISGA Rabat, 27, Address, Zip Code Avenue Oqba, Agdal Rabat
[2] Mohammed V University of Rabat, Smart Sy stems Laboratory (SSL) ENSIAS
[3] Ritm-ESTC/CEDENSE, Hassan II university km7, Route d'El Jadida, Casablanca
来源
International Journal of Circuits, Systems and Signal Processing | 2021年 / 15卷
关键词
Arduino; Circuits; Signal processing; Therapeutic technique;
D O I
10.46300/9106.2021.15.169
中图分类号
学科分类号
摘要
Acupuncture is a centuries-old therapeutic technique. However, because of the large number of complicating circumstances, it has been difficult to clearly prove the treatment's therapeutic effectiveness. As a result, acupuncture has failed to acquire acceptance in the mainstream clinical sector. An electromyography (EMG) sensor was built and used to test the effcacy of acupuncture in alleviating muscular stiffness in this study. Electrodes, differential and inverting ampliffers, fflters, and a full-wave rectiffer made up the EMG circuit. The output of the circuit was sent to a microcontroller for analog-to-digital transformation in order to perform data acquisition. Acupuncture was used to treat four participants who had muscular dys function in various regions of their bodies in our case study. Before and after the therapy, EMG signals at the damaged regions were recorded. The ffndings revealed that the therapy had no immediate conceivable impact on the patients, since the levels of muscular contraction before and after the treatment were comparable. When the EMG signals were measured 30 minutes after the therapy, signs of muscular alleviation were found. This shows that acupuncture does supply patients with beneffcial medicine, although slowly. The act of placing the highly conducting needles into the acupuncture sites, we believe, is similar to connecting a parallel wire to a circuit, resulting in a short-circuited route at the meridian. It permits the meridian's polarized inner energy, or qi, to pass through. The equilibrium in qi regulation can therefore be restored by unclogging the ow of qi.The repair process is relatively slow, and the treatment impact may not be immediately apparent, because the constitutive qualities at the acupuncture points where the needles are pricked may not alter quickly. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
引用
收藏
页码:1571 / 1584
页数:13
相关论文
共 27 条
[1]  
Tsuei J. J., The science of acupuncture-theory and practice, IEEE Eng Med Biol Mag, 15, pp. 52-57, (1996)
[2]  
Lo S.-Y., Meridians in acupuncture and infrared imaging, Med Hypotheses, 58, pp. 72-76, (2002)
[3]  
de Camargo P. S., Lima C. R., Rezende M. L. A. E., Santos A. T. S., Hernandez J. W. R., Silva A. M., The effect of auricular and systemic acupunc- ture on the electromyographic activity of the trapez- ius muscle with trigger points | A pilot study, J Acupunct Meridian Stud, 11, pp. 18-24, (2018)
[4]  
Yeung A., Chan J. S. M., Cheung J. C., Zou L., Qigong and Tai-Chi for mood regulation, Focus, 16, pp. 40-47, (2018)
[5]  
Tsuei J. J., Lam F. M. K., Chou P., Clinical applications of the EDST, IEEE Eng Med Biol Mag, 15, pp. 67-75, (1996)
[6]  
Tough L., Lack of e_ect of acupuncture on electromyo-graphic (EMG) activity - A randomized controlled trial in healthy volunteers, Acupunct Med, 24, pp. 55-60, (2006)
[7]  
Farida I. M., Ismail G., Susanti H., Prasetio M. E., Observation of acupuncture stimulation on human stamina improvement using EMG, 2nd IEEE International Conference on Instrumentation Control and Automation, pp. 71-76, (2011)
[8]  
Reaz M. B. I., Hussain M. S., Mohd-Yasin F., Techniques of EMG signal analysis: Detec- tion, processing, classifcation and applications, Biol Proced Online, 8, pp. 11-35, (2006)
[9]  
DIY Muscle Sensor/EMG Circuit for a Microcontroller. Instructables workshop, (2011)
[10]  
Jamal M. Z., Signal acquisition using surface EMG and circuit design considerations for robotic prosthesis, Comput Intell Electromyogr Anal. Per- spect. Curr. Appl. Future Challenges, 18, pp. 427-448, (2012)