Numerical Study on Post-fire Behavior of High Strength Steel Flush Endplate Connections

被引:0
作者
Qiang X. [1 ]
Shi Z. [1 ]
He X. [2 ]
Jiang X. [1 ]
机构
[1] College of Civil Engineering, Tongji University, Shanghai
[2] China Resources Land(Beijing) Co., Ltd., Beijing
来源
Tongji Daxue Xuebao/Journal of Tongji University | 2019年 / 47卷 / 04期
关键词
Flush endplate connection; High strength steel; Numerical study; Post-fire; Structural fire safety;
D O I
10.11908/j.issn.0253-374x.2019.04.005
中图分类号
学科分类号
摘要
The behavior of high strength steel flush endplate connections on post-fire was simulated according to the test results using finite element software Abaqus. Comparison between the analysis results of finite element method (FEM) and all representative experimental results on moment-rotation relationship, failure mode and stress distribution of flush endplate connections shows that good agreements exist. Based on above, parametric analysis on Q460 high strength steel endplate connections and Q345 mild steel endplate connections was conducted. Results show that: the degradation of mechanical behavior of the connections is not significant after cooling down from fire temperature 550 ℃; the material property of the endplate has no impact on the initial stiffness of the connections but has important impact on the bending capacity of the connections; a connection with thinner high strength steel endplate can achieve similar bending capacity and equivalent or even higher rotation capacity after fire in comparison with a connection with thicker mild steel endplate. © 2019, Editorial Department of Journal of Tongji University. All right reserved.
引用
收藏
页码:482 / 490
页数:8
相关论文
共 24 条
  • [1] Qiang X., Bijlaard F.S.K., Kolstein H., Post-fire mechanical properties of high strength structural steels S460 and S690, Engineering Structure, 35, (2012)
  • [2] Qiang X., Bijlaard F.S.K., Kolstein H., Post-fire performance of very high strength steel S960, Journal of Constructional Steel Research, 80, 1, (2013)
  • [3] Coelho A.M.G., Bijlaard F.S.K., Experimental behaviour of high strength endplate connenctions, Journal of Constructional Steel Research, 63, 9, (2007)
  • [4] Coelho A.M.G., Bijlaard F.S.K., High strength steel in building and civil engineering structures: design of connections, Advances in Structural Engineering, 13, 3, (2010)
  • [5] Sun F., Sun M., Li G., Et al., Experimental study on seismic behavior of high-strength steel beam-to-column endplate connections, Journal of Building Structures, 35, 4, (2014)
  • [6] Yu H., Discussions on the robustness of steel connections in fire, Engineering Mechanics, 28, 4, (2011)
  • [7] BS5950 Structural use of steelwork in building, Part 8: code of practice for fire resistant design, (1998)
  • [8] Qiang X., Shi Z., Jiang X., Et al., Experimental study on high strength steel flush endplate connections after fire, Journal of Hunan University: Natural Sciences, 1, (2019)
  • [9] Shi G., Shi Y., Wang Y., Et al., Numerical simulation of steel pretensioned bolted endplate connections of different types and details, Engineering Structures, 30, 10, (2008)
  • [10] Gao Y., Shi G., Yu H., FEM analysis of flush endplate connections under the combined effect of tension and shear in fire, Engineering Mechanics, 32, 11, (2015)