Thermal performance analysis of naturally ventilated and perforated sheet based double skin facade system for hot summer conditions

被引:0
作者
Sharma M.K. [1 ]
Preet S. [1 ]
Mathur J. [1 ]
Chowdhury A. [1 ]
Mathur S. [1 ]
机构
[1] Centre for Energy and Environment, Malaviya National Institute of Technology, Jaipur
来源
International Journal of Ventilation | 2022年 / 21卷 / 04期
关键词
Double-skin façade; natural ventilation; Nusselt number; perforated sheet; SHGC; thermal performance;
D O I
10.1080/14733315.2021.1901003
中图分类号
学科分类号
摘要
A new skin of perforated sheets in the cavity of double skin facades (DSF) system is introduced for efficient heat removal from the cavity in hot summer conditions. In this paper, the analytical solution is developed to estimate the thermal performance of the double-skin façade system with and without perforated sheet operating under natural ventilation mode. This analytical model is designed to predict the solar heat gain coefficient (SHGC) for hot summer conditions. An experimental investigation has also been conducted to validate the proposed analytical model. Results showed good agreement between the measured and calculated value of SHGC for DSF system with and without perforated sheet. It is observed that the addition of a perforated sheet reduces the SHGC by nearly 51.5% as compared to DSF system. Perforated sheets enable a better stack effect within the air cavity zone and thereby improve heat transfer characteristics. Therefore, the benefit of the perforated sheet within the air cavity of DSF system is profound over conventional DSF system. © 2021 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:263 / 283
页数:20
相关论文
共 28 条
[1]  
Alrashidi H., Ghosh A., Issa W., Sellami N., Mallick T.K., Sundaram S., Thermal performance of semi-transparent CdTe BIPV window at temperate climate, Solar Energy, 195, pp. 536-543, (2020)
[2]  
Andelkovic A.S., Urosevic B.G., Kljajic M., Lgnjatovic M.G., Experimental research of the thermal characteristics of multi-storey naturally ventilated double skin façade, Energy and Buildings, 86, pp. 766-781, (2015)
[3]  
Bakar N.N.A., Hassan M.Y., Abdullah H., Rahman H.A., Abdullah M.P., Hussin F., Bandi M., Energy efficiency index as an indicator for measuring building energy performance: A review, Renewable and Sustainable Energy Reviews, 44, pp. 1-11, (2015)
[4]  
Bansal N.K., Mathur J., Mathur S., Jain M., Modeling of window-sized solar chimneys for ventilation, Building and Environment, 40, 10, pp. 1302-1308, (2005)
[5]  
Barman S., Chowdhury A., Mathur S., Mathur J., Assessment of the efficiency of window integrated CdTe based semi-transparent photovoltaic module, Sustainable Cities and Society, 37, pp. 250-262, (2018)
[6]  
Berardi U., A cross-country comparison of the building energy consumptions and their trends, Resources, Conservation and Recycling, 123, pp. 230-241, (2017)
[7]  
Blanco J.M., Arriaga P., Roji E., Cuadrado J., Investigating the thermal behaviour of double skin perforated sheet facades: Part A: Model characterization and validation procedure, Building and Environment, 82, pp. 50-62, (2014)
[8]  
Blanco J.M., Buruaga A., Roji E., Cuadrado J., Pelaz B., Energy assessment and optimization of perforated metal sheet double skin facades through design builder, Energy and Buildings, 111, pp. 326-336, (2016)
[9]  
Cengel Y.A., Ghajar A.J., Heat and mass transfer: Fundamentals and applications, (2017)
[10]  
Chan A.L.S., Chow T.T., Fong K.F., Lin Z., Investigation on energy performance of double skin façade in Hong Kong, Energy and Buildings, 41, 11, pp. 1135-1142, (2009)