Coordinate control of grid-connected converter based on QPSO under unbalanced grid voltage

被引:0
|
作者
Liu J. [1 ]
Zhao C.-C. [1 ]
Xie Z.-H. [2 ]
Zhou F.-H. [1 ]
机构
[1] College of Automation, Xi'an University of Technology, Xi'an
[2] Xi'an Thermal Power Research Institute Co. Ltd, Xi'an
来源
Kongzhi yu Juece/Control and Decision | 2021年 / 36卷 / 04期
关键词
(QPSO); Coordinate control; Current harmonic distortion rate; Grid-connected converter; Power fluctuation; Quantum particle swarm optimization; Unbalance grid voltage;
D O I
10.13195/j.kzyjc.2019.0885
中图分类号
学科分类号
摘要
Under unbalanced grid voltage, the ride-through operation of wind power systems will lead to fluctuations on output power and obvious harmonic distortion in grid-connected current. For the problem of that the constant output power and good current quality can not be achieved simultaneously, a power/current coordinate control scheme based on the quantum particle swarm optimization (QPSO) algorithm is proposed. The regulation coefficients α and β are introduced into the calculation of reference current, and the relationships between the amplitude of power fluctuations, the harmonic distortion rate of current and the regulation coefficients are deduced. In order to take the power and current into account, the optimization model of the regulation coefficients is established with the minimum fluctuations on output power as the control objective and the current harmonic distortion limit as the constraint condition. Under the condition of different types of voltage unbalance faults, the coordinate control of power and current is realized using Matlab, which verifies the feasibility and effectiveness of the proposed control scheme. Copyright ©2021 Control and Decision.
引用
收藏
页码:901 / 908
页数:7
相关论文
共 16 条
  • [1] Jiang W D, Wu Z Q, She Y Y, Et al., Control strategy of suppressing power secondary fluctuations of grid-connected inverter based on unbalanced grid, Automation of Electric Power Systems, 38, 15, pp. 106-111, (2014)
  • [2] Miret J, Castilla M, Camacho A, Et al., Control scheme for photovoltaic three-phase inverters to minimize peak currents during unbalanced grid-voltage sags, IEEE Transactions on Power Electronics, 27, 10, pp. 4262-4271, (2012)
  • [3] Kim K H, Jeung Y C, Lee D C, Et al., LVRT scheme of PMSG wind power systems based on feedback linearization, IEEE Transactions on Power Electronics, 27, 5, pp. 2376-2384, (2012)
  • [4] Suh Y, Lipo T A., Control scheme in hybrid synchronous synchronous stationary frame for PWM AC-DC converter under generalized unbalanced operating conditions, IEEE Transactions on Industry Applications, 42, 3, pp. 825-835, (2006)
  • [5] Ma K, Chen W J, Liserre M, Et al., Power controllability of a three-phase converter with an unbalanced AC source, IEEE Transactions on Power Electronics, 30, 3, pp. 1591-1604, (2015)
  • [6] Wei X Y, Lu Y., A unified control strategy for VSC-HVDC under unbalanced grid conditions, Proceedings of the CSEE, 32, 34, pp. 50-57, (2012)
  • [7] Guo X Q, Wu W Y., Improved current regulation of three-phase grid-connected voltage-source inverters for distributed generation systems, IET Renewable Power Generation, 4, 2, pp. 101-115, (2010)
  • [8] Jiang W D, Wu Z Q, Hu Y, Et al., Analysis of control strategy for grid-connected inverter under different constraints based on asymmetric grid, Automation of Electric Power Systems, 39, 19, pp. 113-120, (2015)
  • [9] Huang S D, Xiao L, Huang K Y, Et al., Operation and control on the grid-side converter of the directly-driven wind turbine with PM synchronous generator during asymmetrical faults, Transactions of China Electrotechnical Society, 26, 2, pp. 173-180, (2011)
  • [10] Rodriguez P, Timbus A V, Teodorescu R, Et al., Independent PQ control for distributed power generation systems under grid faults, The Annual Conference on IEEE Industrial Electronics, pp. 5185-5190, (2006)