Impact of Flattening Filter Free Photon Beam on Rapidarc Radiotherapy for Gynaecological Malignancies: A Comparative Study

被引:0
作者
Kumar L. [1 ,2 ]
Kishore V. [3 ]
Bhushan M. [2 ]
Yadav G. [2 ]
Dewan A. [2 ]
Kumar P. [2 ]
Kumar G. [2 ]
Chowdhary R.L. [2 ]
机构
[1] Department of Applied Science and Humanities, Dr. A.P.J Abdul Kalam Technical University, Lucknow
[2] Medical Physics Division and Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi
[3] Department of Applied Science and Humanities, Bundelkhand Institute of Engineering and Technology, Jhansi
来源
Iranian Journal of Medical Physics | 2021年 / 18卷 / 01期
关键词
Gynecology; Photon Energy; Radiotherapy; Treatment Planning;
D O I
10.22038/ijmp.2019.35081.1650
中图分类号
学科分类号
摘要
Introduction: To compare the dosimetric outcomes of 6 and 10 MV flattening filter free beam (FFFB) energies in gynaecological malignancies RapidArc (RA) planning. Material and Methods: The RA plans were generated for a cohort of 20 patients using 6 and 10 MV FFFBs. The plans aimed to deliver a dose of 50.4Gy in 28 fractions to planning target volume (PTV); moreover, planning objectives were kept as low as reasonably achievable for organs at risk (OARs). Dosimetric analysis was performed in terms of PTV coverage, conformity index (CI), homogeneity index (HI), dose to OAR’s, integral dose to normal tissue (NTID), and total number of monitor units (MU’s). Results: According to the results, volumes of PTV receiving prescription dose and CI values were 95.03±0.10% and 95.02±0.18%, as well as 1.018±0.028 and 1.024±0.027, respectively. Moreover, HI values were estimated at 1.063±0.008 and 1.068±0.010. Additionally, the corresponding values of mean NTID and MUs were 280.3±42.5 and 267.9±39.1 (liter-Gy), as well as 610.3±30.3 and 630.6±39.7 for FFFB using 6 and 10 MV, respectively. The 6 and 10 MV FFFBs were statistically similar in terms of mean dose to bladder, rectum and both femoral heads, while comparison yielded significant difference (P<0.05) in terms of HI, CI, MUs and NTID. Conclusion: The FFFB of 6MV was found superior, compared to 10MV, for RA planning in case of gynaecological malignancies. Moreover, it offers better HI and CI values, as well as fewer numbers of MUs (3.33%). In addition, it delivers more NTID (4.42%) for similar target coverage and OAR’s sparing. © 2020. All Rights Reserved.
引用
收藏
页码:23 / 29
页数:6
相关论文
共 50 条
  • [41] Local dose rate effects in implantable cardioverter-defibrillators with flattening filter free and flattened photon radiation
    Gauter-Fleckenstein, Benjamin
    Tueluemen, Erol
    Rudic, Boris
    Borggrefe, Martin
    Polednik, Martin
    Fleckenstein, Jens
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (06) : 566 - 572
  • [42] Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams
    Cashmore, Jason
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 293 - 307
  • [43] Impact of flattening filter-free beams on remaining volume at risk in lung cancer treatment
    Alfishawy, Mahmoud Mohamed
    Kany, Amr Ismail
    Elshahat, Khaled Mohamed
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 455 - 464
  • [44] A Monte Carlo study of a flattening filter-free linear accelerator verified with measurements
    Dalaryd, Marten
    Kragl, Gabriele
    Ceberg, Crister
    Georg, Dietmar
    McClean, Brendan
    af Wetterstedt, Sacha
    Wieslander, Elinore
    Knoos, Tommy
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23) : 7333 - 7344
  • [45] Characterisation of flattening filter free (FFF) beam properties for initial beam set-up and routine QA, independent of flattened beams
    Paynter, D.
    Weston, S. J.
    Cosgrove, V. P.
    Thwaites, D. I.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01)
  • [46] Evaluation of the dosimetric impact of applying flattening filter-free beams in intensity-modulated radiotherapy for early-stage upper thoracic carcinoma of oesophagus
    Zhang, Wuzhe
    Lin, Zhixiong
    Yang, Zhining
    Fang, Weisheng
    Lai, Peibo
    Lu, Jiayang
    Wu, Vincent W. C.
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2015, 62 (02) : 108 - 113
  • [47] Effect of dose-delivery time for flattened and flattening filter-free photon beams based on microdosimetric kinetic model
    Nakano, Hisashi
    Kawahara, Daisuke
    Ono, Kaoru
    Akagi, Yukio
    Hirokawa, Yutaka
    [J]. PLOS ONE, 2018, 13 (11):
  • [48] Experimental pencil beam kernels derivation for 3D dose calculation in flattening filter free modulated fields
    Azcona, Juan Diego
    Barbes, Benigno
    Wang, Lilie
    Burguete, Javier
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01) : 50 - 66
  • [49] Use of flattening filter free photon beams for off-axis targets in conformal arc stereotactic body radiation therapy
    Smith, A.
    Kim, S.
    Serago, C.
    Hintenlang, K.
    Hintenlang, D.
    Heckman, M.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 448 - 451
  • [50] A 4 MV flattening filter-free beam: commissioning and application to conformal therapy and volumetric modulated arc therapy
    Stevens, S. W.
    Rosser, K. E.
    Bedford, J. L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (13) : 3809 - 3824