Analysis of harmonic interaction between internal units of direct drive wind farm based on RGA and αβ coordinate system

被引:0
|
作者
基于RGA和RGA坐标系的直驱风场内机组间谐波交互分析
机构
[1] Han, Pingping
[2] Wang, Longjian
[3] Dou, Sheng
[4] Wang, Lei
来源
Wang, Longjian (wljhfut@163.com) | 1600年 / Power System Protection and Control Press卷 / 48期
关键词
Electric current control - Electric utilities - Hardware-in-the-loop simulation - Harmonic analysis - MATLAB - Simulation platform - Synthetic apertures - Topology - Wind farm - Wind turbines;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:29 / 40
相关论文
共 50 条
  • [1] Analysis and verification of harmonic interaction between DDWTs based on αβ stationary coordinate system
    Han, Pingping
    Wang, Longjian
    Dou, Sheng
    Wang, Lei
    Bi, Rui
    Yang, Xiangzhen
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (10) : 1893 - 1901
  • [2] Research on Subsynchronous Interaction between direct-drive PMSG based Wind Farm and Static Var Generator
    Jiang Hongli
    Ma Shiying
    Song Ruihua
    Xiang Zutao
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 1160 - 1165
  • [3] Evaluation of damping of subsynchronous interaction between direct-drive wind farm and LCC-HVDC based on the damping path analysis
    Gao, Benfeng
    Deng, Pengcheng
    Wang, Yi
    Yu, Hongyang
    Ren, Bixing
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 144
  • [4] Grouping method of direct drive wind farm based on principal component analysis
    Yan X.
    Li J.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (05): : 127 - 133
  • [5] Stability analysis of sub/super synchronous oscillation in direct-drive wind farm considering the energy interaction between PMSGs
    Ma, Jing
    Xu, Honglu
    Zhang, Min
    Cheng, Peng
    IET RENEWABLE POWER GENERATION, 2022, 16 (03) : 478 - 496
  • [6] Stability analysis for direct-drive permanent magnet synchronous generator based wind farm integration system considering wind speed
    Zou, Xiaoming
    Du, Xiong
    Tai, Heng-Ming
    IET RENEWABLE POWER GENERATION, 2020, 14 (11) : 1894 - 1903
  • [7] Harmonic analysis and its restraining in wind power system with direct drive permanent magnet generator
    Rong, Fei
    Zhou, Xian-Zheng
    Fan, Qing
    Luo, An
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2010, 37 (4 SUPPL.): : 104 - 109
  • [8] Influence of Grid Connected Direct Drive Wind Farm on Subsynchronous Resonance of Thermal Power Units
    Gao B.
    Liu P.
    Liu W.
    Dong L.
    Zhang R.
    Han B.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (11): : 3308 - 3322
  • [9] Singular Perturbation Approximation Method Based on the Dominant Degree Analysis for Direct Drive Wind Farm
    Gao, Benfeng
    Wang, Gang
    Shao, Bingbing
    Liu, Yi
    Xiang, Ling
    Zhao, Shuqiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (07): : 2449 - 2461
  • [10] Subsynchronous Oscillation Mechanism Analysis of Direct-drive Wind Farm With VSC-HVDC System Based on Path Analysis Method
    Gao B.
    Liu Y.
    Wang X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (17): : 6646 - 6659