关键词
Ageing time; partial discharge; polyimide films; power electronic transformer; temperature;
D O I
10.24295/CPSSTPEA.2023.00028
中图分类号
学科分类号
摘要
Under the combination of temperature and high frequency electrical stress, partial discharge (PD) intensity will increase at the insulation system of power electronic transformer (PET), which leads to premature insulation failure, and finally threatens the reliability of PET. In order to obtain PD features under high frequency square wave voltage combined with high temperature, and different aging time of insulation system in PET. A combined electric-thermal experiment platform is established to simulate the discharge characteristics of typical insulation dielectric films (polyimide, PI) under temperature from 80∼155 °C and ageing time from 0∼50 h respectively. The variation trend of discharge repetition rate, average discharge amplitude and the shape of phase resolved partial discharge (PRPD) spectrum are considered, and then the discharge mechanism is analyzed. The experimental results show that the rise of temperature contribute to the augmentation of discharge repetition rate and the average discharge amplitude, with an increase in amplitude from 0.3 V to 0.6 V, and the phase of the discharge signal widens. As the ageing time goes up, the discharge repetition rate and the average discharge amplitude increase too, but the change is most obvious in the early aging period, leaping from 0.2 V to 0.32 V. It is of practical value to reveal the mechanism of high frequency electro-thermal stress and improve the operation reliability of power electronic transformer. © 2017 CPSS.
引用
收藏
页码:363 / 371
页数:8
相关论文
共 50 条
  • [31] Low Cost System for Partial Discharge Monitoring in Power Transformers by Piezoelectric Sensors
    Castro, B. A.
    Clerice, G. A. M.
    Andreoli, A. L.
    Campos, F. S.
    Ulson, J. A. C.
    IEEE LATIN AMERICA TRANSACTIONS, 2016, 14 (07) : 3225 - 3231
  • [32] Partial discharge characteristics of oil-paper insulation for on-board traction transformers under superposed inter-harmonic AC voltages
    Li, Xiaonan
    Wu, Guangning
    Yang, Yan
    Wang, Zijie
    Xu, Ping
    Li, Yixuan
    Gao, Bo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (01) : 240 - 248
  • [33] Design Optimization of Power Capacitor Major Insulation based on Partial Discharge Performance
    Cheng Lu
    Li Zhou
    Liu Wenfeng
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 282 - 286
  • [34] Partial Discharge Characteristics and Development of Typical XLPE Power Cable Insulation Defects
    Zhao, Xuefeng
    Pu, Lu
    Ju, Zeli
    Ren, Shuangzan
    Duan, Wei
    Wang, Jianhui
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 623 - 626
  • [35] New high temperature polyimide insulation for partial discharge resistance in harsh environments
    Katz, M
    Theis, RJ
    IEEE ELECTRICAL INSULATION MAGAZINE, 1997, 13 (04) : 24 - 30
  • [36] Investigating suitable features for Partial Discharge localization in power transformer
    Homaei, M.
    Jafari, A. Mazhab
    Akbari, A.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 923 - +
  • [37] ENERGY CHARACTERISTICS OF POLYMER INSULATION DIELECTRIC STRENGTH UNDER PARTIAL DISCHARGE STRESS
    ARONOV, MA
    KOKURKIN, MP
    ELECTRICAL TECHNOLOGY, 1994, (03): : 49 - 61
  • [38] Partial Discharge Features and Parameters Characterization Under Typical Defect Geometries in Oil-Paper Insulation: Considering the Aging States
    Li, Yuan
    Zhang, Guan-Jun
    Zhu, Ming-Xiao
    Wei, Yan-Hui
    Mu, Hai-Bao
    Deng, Jun-Bo
    Wei, Bin
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [39] The Comparative Analysis of The Partial Discharge In The Inter-turn Insulation of Transformers Between Constant Voltage and Increasing Voltage
    Ji, Hongxin
    Cheng, Yangchun
    Wei, Jingqing
    Liu, Shaoyu
    Deng, Chun
    Li, Chengrong
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 211 - 216
  • [40] Using Fuzzy ARTmap Neural Network for Determination of Partial Discharge Location in Power Transformers
    Nafisi, H.
    Davari, M.
    Abedi, M.
    Gharehpetian, G. B.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 1512 - 1515