Free flap perfusion prediction by laser doppler flowmetry based time series analysis

被引:0
|
作者
Kodama H. [1 ]
Ishida K. [1 ]
Hirayama H. [1 ]
Kishi K. [1 ]
Miyawaki T. [1 ]
机构
[1] Department of Plastic and Reconstructive surgery, The Jikei University School of Medicine
关键词
ARMA; free flap; laser doppler flowmetry; LSTM; time series analysis;
D O I
10.11239/jsmbe.Annual59.626
中图分类号
学科分类号
摘要
Flap ischemia and consecutive flap loss is an innate complication in reconstructive free flap surgery. With the development of machine learning, time series analysis based flap failure prediction has become possible. With the laser doppler flowmetry pocket device (PocketLDF®) by JMS it has become possible to measure skin perfusion every second. In this trial skin perfusion in addition to blood pressure, pulse and respiratory rate were measured in 3 patients and flap failure prediction based on the Auto-Regressive Moving Average (ARMA) model and the Long Short Term Memory (LSTM) network was conducted. Accurate perfusion prediction with the ARMA model for stationary processes and with the LSTM network for non-stationary processes was possible. In comparison with real time observation by the attending doctor, the ARMA model was able to predict flap ischemia ahead of time. © 2021, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
引用
收藏
页码:628 / 630
页数:2
相关论文
共 50 条
  • [21] Evaluation of a novel probe based on laser Doppler flowmetry and comparison with photo plethysmography for assessment of the skin perfusion pressure
    Thogersen, Karin Folmer
    Rasmussen, Karl Keigo
    Hoyer, Christian
    Zerahn, Bo
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2022, 82 (03) : 238 - 245
  • [22] Minimally invasive laser Doppler flowmetry is suitable for serial bone perfusion measurements in mice
    Hanne, Nicholas J.
    Easter, Elizabeth D.
    Cole, Jacqueline H.
    BONE REPORTS, 2019, 11
  • [23] Dopexamine does not improve intestinal mucosal perfusion measured by scanning laser Doppler flowmetry
    NH Boyle
    PC Roberts
    A McLukie
    L Giles
    RJ Beale
    RC Mason
    Critical Care, 3 (Suppl 1):
  • [24] A note on the compartmental analysis and related issues in laser Doppler flowmetry
    Zhong, JC
    Nilsson, GE
    Salerud, GE
    Seifalian, AM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (04) : 534 - 537
  • [25] Model-based quantitative laser Doppler flowmetry in skin
    Fredriksson, Ingemar
    Larsson, Marcus
    Stromberg, Tomas
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (05)
  • [26] A mathematical analysis on the biological zero problem in laser Doppler flowmetry
    Zhong, JC
    Seifalian, AM
    Salerud, GE
    Nilsson, GE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (03) : 354 - 364
  • [27] Continual measurement of intramedullary blood perfusion with laser Doppler flowmetry in intact and ostectomized tibiae of rabbits
    Hackenbroich, Ch
    Wagner, S.
    Windhagen, H.
    Meyer-Lindenberg, A.
    LABORATORY ANIMALS, 2008, 42 (03) : 305 - 319
  • [28] A LASER DOPPLER FLOWMETRY FOR MEASURING THE PULP BLOOD PERFUSION IN TEETH WITH POSTOPERATIVE SENSITIVITY - a case report
    Stefanova, Vesela
    Manchorova, Neshka
    Georgieva, Desislava
    Sapundgiev, Angel
    Nikova, Yoanna
    Simeonov, Georgy
    Kaish, Emina
    Antipova, Isabela
    Stoyanova, Maria
    Simeonov, Nikolay
    Tzanova, Snejana
    Vladimirov, Stoyan
    JOURNAL OF IMAB, 2016, 22 (04): : 1383 - 1384
  • [29] Influence of restorative manipulations on the blood perfusion of human marginal gingiva as measured by laser Doppler flowmetry
    Vág, J
    Fazekas, A
    JOURNAL OF ORAL REHABILITATION, 2002, 29 (01) : 52 - 57
  • [30] Effect of a decreased ocular perfusion pressure on iris blood flow measured with laser Doppler flowmetry
    Chamot, SR
    Movaffaghy, A
    Petrig, BL
    Riva, CE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 214 (05) : 302 - 304