Booster heat pump with drop-in zeotropic mixtures applied in ultra-low temperature district heating system

被引:2
作者
Zhu, Tingting [1 ,2 ]
Vieren, Elias [3 ]
Liang, Jierong [1 ,4 ]
Thorsen, Jan Eric [5 ]
De Paepe, Michel [3 ,6 ]
Lecompte, Steven [3 ,6 ]
Elmegaard, Brian [1 ]
机构
[1] Tech Univ Denmark, Dept Civil & Mech Engn, DK-2800 Lyngby, Denmark
[2] Univ Twente, Dept Thermal & Fluid Engn, NL-7522 NB Enschede, Netherlands
[3] Univ Ghent, Dept Electromech Syst & Met Engn, B-9000 Ghent, Belgium
[4] MAGNOTHERM Solut GmbH, Pfungstadter Str 102, D-64297 Darmstadt, Germany
[5] Danfoss A S, Nordborg, Denmark
[6] FlandersMake, UGENT Core Lab, EEDT MP, B-3000 Leuven, Belgium
关键词
Booster heat pump; District heating; Zeotropic mixture; Domestic hot water; Exergetic efficiency; REFRIGERANTS; PERFORMANCE;
D O I
10.1016/j.energy.2024.132292
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pursuit of sustainable district heating solutions has driven a growing interest in ultra-low temperature district heating (ULTDH) systems, where booster heat pumps (BHPs) play a pivotal role despite challenges posed by their efficiency limitations under large temperature glide conditions. This paper investigates the potential of drop-in R-1234yf/R-32 zeotropic mixtures in BHPs compared to a baseline R-134a system, within the context of a ULTDH framework. This study focused on the viability of the mixtures of R-1234yf/R-32 with the composition ratio of 80 %/20 % and 90 %/10 %. The investigation reveals disparities in compressor efficiency and heat exchanger pressure drop at the component level. Device-level analysis unveils increased COP for R-1234yf/R-32 mixtures, alongside with maximum second-law efficiencies reaching 0.32. A remarkable enhancement in heating capacity up to 58 % was found. System-level analysis demonstrated exergetic efficiencies and identified preferable district heating temperatures. Exergetic efficiencies of 0.47, 0.55, and 0.59 were achieved for domestic hot water preparation at district heating supply temperatures of 30 degrees C, 35 degrees C, and 40 degrees C, with a subsequent shift in optimal district heating temperatures as central heating station efficiency decreased. Temperature profile analysis underscored challenges stemming from excessive subcooling, highlighting the need for configuration refinements.
引用
收藏
页数:13
相关论文
共 39 条
  • [31] Feasibility and performance study on hybrid air source heat pump system for ultra-low energy building in severe cold region of China
    Xu, Wei
    Liu, Changping
    Li, Angui
    Li, Ji
    Qiao, Biao
    RENEWABLE ENERGY, 2020, 146 (146) : 2124 - 2133
  • [32] New low temperature industrial waste heat district heating system based on natural gas fired boilers with absorption heat exchangers
    Sun, Fangtian
    Cheng, Lijiao
    Fu, Lin
    Gao, Junwei
    APPLIED THERMAL ENGINEERING, 2017, 125 : 1437 - 1445
  • [33] A renewable energy scenario for a new low carbon settlement in northern Italy: Biomass district heating coupled with heat pump and solar photovoltaic system
    Aste, Niccolo
    Caputo, Paola
    Del Pero, Claudio
    Ferla, Giulio
    Huerto-Cardenas, Harold Enrique
    Leonforte, Fabrizio
    Miglioli, Alessandro
    ENERGY, 2020, 206
  • [34] Low-temperature air source heat pump system for heating in severely cold area: Long-term applicability evaluation
    Wu, Chunling
    Liu, Fang
    Li, Xiaofeng
    Wang, Zhichao
    Xu, Zhaowei
    Zhao, Wenyuan
    Yang, Yingxia
    Wu, Pin
    Xu, Ce
    Wang, Yichao
    BUILDING AND ENVIRONMENT, 2022, 208
  • [35] Modelling and multi-scenario analysis for electric heat tracing system combined with low temperature district heating for domestic hot water supply
    Xiaochen Yang
    Hongwei Li
    Svend Svendsen
    Building Simulation, 2016, 9 : 141 - 151
  • [36] Modelling and multi-scenario analysis for electric heat tracing system combined with low temperature district heating for domestic hot water supply
    Yang, Xiaochen
    Li, Hongwei
    Svendsen, Svend
    BUILDING SIMULATION, 2016, 9 (02) : 141 - 151
  • [37] Experimental assessment of the first industrial implementation of ejector refrigeration system operating with R1233zd(E) driven by ultra-low temperature heat source
    Gagan, Jerzy
    Smierciew, Kamil
    Lukaszuk, Michal
    Butrymowicz, Dariusz
    Pawluczuk, Andrzej
    Mastrowski, Mikolaj
    Bergander, Marek
    Cebula, Artur
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 154 : 138 - 150
  • [38] Novel solar-driven low temperature district heating and cooling system based on distributed half-effect absorption heat pumps with lithium bromide
    Sun, Fangtian
    Zhao, Xiaoqing
    Hao, Baoru
    ENERGY, 2023, 270
  • [39] Configuration optimization of solar-driven low temperature district heating and cooling system integrated with distributed water-lithium bromide absorption heat pumps
    Sun, Fangtian
    Xu, Wanqing
    Chen, Hongbing
    Hao, Baoru
    Zhao, Xiaoqing
    SOLAR ENERGY, 2023, 253 : 401 - 413