SECOND-ORDER ACTIVE DISTURBANCE REJECTION CONTROL OF DIRECT-DRIVEN PERMANENT MAGNET SYNCHRONOUS GENERATORS CONSIDERING INFLUENCE OF CONVERTER

被引:0
|
作者
Zhu K. [1 ,2 ]
Ruan L. [1 ,2 ]
机构
[1] Institute of Electrical Engineering Chinese Academy of Sciences, Beijing
[2] University of Chinese Academy of Sciences, Beijing
来源
关键词
control strategy; converter; robustness; second-order active disturbance rejection controller; wind power;
D O I
10.19912/j.0254-0096.tynxb.2021-1035
中图分类号
学科分类号
摘要
An electric control system of direct-drive permanent magnet synchronous generator based on new active disturbance rejection technology is studied. Considering the influence of the converter on the output voltage of the control system,a mathematical model of the generator set is established,and based on this,a second-order active disturbance rejection controller(ADRC)is designed. The proposed extended state observer and the convergence of the controller are analyzed,and the control parameter configuration method is given. The feasibility and control performance of the proposed control system are quantitatively analyzed by simulation. The results show that the proposed control system can control the operation process of the generator set quickly and stably,and has better dynamic performance and robust performance than the traditional vector control and first-order ADRC. © 2023 Science Press. All rights reserved.
引用
收藏
页码:87 / 92
页数:5
相关论文
共 16 条
  • [1] SEN P,, Et al., High-power wind energy conversion systems:state-of-the-art and emerging technologies[J], Proceedings of the IEEE, 103, 5, pp. 740-788, (2015)
  • [2] FANG Y Y, ZENG Z Z, WANG K Y,, Et al., Improved integral sliding mode control for maximum power tracking of permanent magnet direct drive wind power generation system[J], Power system protection and control, 47, 5, pp. 77-83, (2019)
  • [3] ZHU B., Introduction to active disturbance rejection control [M], (2017)
  • [4] ZHU J Q, SUN P K, Et al., Traction control strategy of high speed maglev train based on active disturbance rejection[J], Transactions of China Electrotechnical Society, 35, 5, pp. 151-160, (2020)
  • [5] MA Y F, LI X, Et al., Design of wide- area additional damping controller for doubly- fed wind farm considering the effect of time delay[J], Transactions of China Electrotechnical Society, 35, 1, pp. 158-166, (2020)
  • [6] GAO Z Q,, LI S,, ZHOU X S,, Et al., Application of linear active disturbance rejection in photovoltaic power generation system MPPT[J], Power system protection and control, 46, 15, pp. 52-59, (2018)
  • [7] FANG Y Y,, ZENG Z Z,, LIU Q,, Et al., Nonlinear disturbance rejection control for maximum power tracking of permanent magnet direct drive wind power system[J], Power system protection and control, 527, 5, pp. 153-159, (2019)
  • [8] DU B C, SONG L W,, Et al., A noise suppression method of IPMSM position sensorless high-frequency injecting current based on variable frequency current signal [J], Transactions of China Electrotechnical Society, 35, 18, pp. 54-61, (2020)
  • [9] LI S,, CAO M,, LI J,, Et al., Sensorless based active disturbance rejection control for a wind energy conversion system with permanent magnet synchronous generator[J], IEEE access, 26, 1, pp. 663-674, (2019)
  • [10] SUN D S, ZHANG Y J., Active disturbance rejection control and position sensorless control of embedded permanent magnet synchronous motor with high frequency signal injection[J], Control theory & applications, 34, 4, pp. 508-514, (2017)