Detection of partial discharge patterns in hybrid high voltage power transmission lines based on parallel recognition method

被引:0
|
作者
Yang Y. [1 ]
Wu Y. [2 ]
Gao Y. [3 ]
Huang Y. [4 ]
Liu S. [5 ]
Wang Y. [6 ]
机构
[1] Xihua University, Chengdu
[2] Chengdu Power Supply Company, State Grid Sichuan Electric Power Company, Chengdu
[3] Chongqing University of Posts and Telecommunications, Chongqing
[4] Queen Mary University of London, London
[5] Nanyang Technological University, Nanyang
[6] University of Sheffield, Sheffield
关键词
BPNN; Dung beetle optimization algorithm; Hybrid high-voltage power transmission lines; Orthogonal contrastive learning; Partial discharge;
D O I
10.7717/PEERJ-CS.2045
中图分类号
学科分类号
摘要
Due to their specially designed structures, the partial discharge detection of hybrid highvoltage power transmission lines (HHVPTL) composed of overhead lines and power cables has made it difficult to monitor the conditions of power transmission lines. A parallel recognition method for partial discharge patterns of HHVPTLs is proposed by implementing wavelet analysis and improved backpropagation neural network (BPNN) to address the shortcomings of low efficiency, poor accuracy, and inability to parallel analysis of current partial discharge (PD) detection algorithms for HHVPTLs. Firstly, considering the non-smoothness of the partial discharge of the HHVPTLs, the wavelet packet decomposition algorithm is implemented to decompose the PD of the HHVPTL and resolve the relevant signal indicators to form the attribute vectors. Then, BPNN is implemented as a classification model. A beetle optimization (DBO) algorithm based on orthogonal contrastive learning improvement is introduced to optimize the BPNN parameters since BPNN has a slow convergence problem and fails easily into a local optimum. The proposed IDBO-BPNN is employed as the model that recognizes and analyzes the parallel partial discharge patterns of HHVPTLs. Finally, the suggested model is implemented to investigate the local discharge data of an HHVPTL in the Kaggle Featured Prediction Competition and is compared with other algorithms. The experimental results indicate that the proposed model can more accurately identify whether PDs occur in an HHVPTL and detect phases where PDs occur, with higher overall accuracy and efficiency. An excellent practical performance is achieved. The proposed model can achieve the recognition accuracy of 95.5%, which is 5.3333% higher than that of the DBO-BPNN and far more than other recognition algorithms. © (2024), Yang et al.
引用
收藏
相关论文
共 50 条
  • [11] Partial Discharge Detection Using Acoustic and Optical Methods in High Voltage Power Equipments: A Review
    Al Saedi, Malik Abdul Razzaq
    Yaacob, Mohd Muhridza
    MATERIALS, INDUSTRIAL, AND MANUFACTURING ENGINEERING RESEARCH ADVANCES 1.1, 2014, 845 : 283 - 286
  • [12] Monitoring of high voltage power transformer using direct optical partial discharge detection technique
    Karmakar, S.
    Roy, N. K.
    Kumbhakar, P.
    JOURNAL OF OPTICS-INDIA, 2009, 38 (04): : 207 - 215
  • [13] Partial discharge detection in power lines using automated machine learning
    Rivas, Jannery
    Boya-Lara, Carlos
    Poveda, Hector
    2022 8TH INTERNATIONAL ENGINEERING, SCIENCES AND TECHNOLOGY CONFERENCE, IESTEC, 2022, : 223 - 230
  • [14] A Convolutional Neural Network-Based Deep Learning Methodology for Recognition of Partial Discharge Patterns from High-Voltage Cables
    Peng, Xiaosheng
    Yang, Fan
    Wang, Ganjun
    Wu, Yijiang
    Li, Lee
    Li, Zhaohui
    Bhatti, Ashfaque Ahmed
    Zhou, Chengke
    Hepburn, Donald M.
    Reid, Alistair J.
    Judd, Martin D.
    Siew, Wah Hoon
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (04) : 1460 - 1469
  • [15] Feature extraction based on time-series topological analysis for the partial discharge pattern recognition of high-voltage power cables
    Sun, Kang
    Li, Rui
    Zhao, Laijun
    Li, Ziqiang
    MEASUREMENT, 2023, 217
  • [16] Partial Discharge Detection and Induced Surface Current Analysis Using Transient Earth Voltage Method for High Voltage Equipment
    Itose, Akihiko
    Kozako, Masahiro
    Hikita, Masayuki
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 456 - 460
  • [17] Measurement and Analysis of Partial Discharge of High and Medium Voltage Power Equipment
    Chou, Chih-Ju
    Chen, Chien-Hsun
    2018 7TH IEEE INTERNATIONAL SYMPOSIUM ON NEXT-GENERATION ELECTRONICS (ISNE), 2018, : 298 - 301
  • [18] Pattern recognition of typical defects in high-voltage storage capacitors based on DC partial discharge
    GuangNing Wu
    ShanShan Bian
    LiRen Zhou
    XueQin Zhang
    HanZheng Ran
    ChengLong Yu
    Science in China Series E: Technological Sciences, 2009, 52 : 3729 - 3735
  • [19] Pattern recognition of typical defects in high-voltage storage capacitors based on DC partial discharge
    Wu GuangNing
    Bian ShanShan
    Zhou LiRen
    Zhang XueQin
    Ran HanZheng
    Yu ChengLong
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2009, 52 (12): : 3729 - 3735
  • [20] Pattern recognition of typical defects in high-voltage storage capacitors based on DC partial discharge
    WU GuangNing 1
    2Mailbox919-518
    Science in China(Series E:Technological Sciences), 2009, (12) : 3729 - 3735