Wideband Wearable antenna for Biomedical Telemetry applications

被引:0
|
作者
Smida A. [1 ,2 ]
Iqbal A. [3 ,4 ]
alazemi a.J. [5 ]
Waly M.I. [6 ,7 ]
Ghayoula R. [8 ,9 ]
Kim S. [6 ]
机构
[1] Department of Medical Equipment Technology, College of applied Medical Sciences, Majmaah University, alMajmaah
[2] Unit of Research in High Frequency Electronic Circuits and Systems, Faculty of Mathematical, Physical, and Natural Sciences of Tunis, Tunis El Manar University, Tunis
[3] Centre for Wireless Technology, Faculty of Engineering, Multimedia University, Cyberjaya
[4] Department of Electrical Engineering, CECOS, University of IT and Emerging Sciences, Peshawar
[5] Department of Electrical Engineering, Faculty of Engineering and Petroleum, Kuwait University, Kuwait
[6] School of Electrical Engineering, University of Ulsan, Ulsan
[7] Department of Biomedical Engineering and System, Higher Institute of Engineering, El Shorouk academy, al Shorouk
[8] Department of Electrical and Computer Engineering, Laval University, Quebec, G1V0a6, QC
[9] Unit of Research in High Frequency Electronic Circuits and Systems, Faculty of Mathematical, Physical and Natural Sciences of Tunis, Tunis El Manar Manar University, Tunis
基金
新加坡国家研究基金会;
关键词
biomedical antenna; flexible antenna; On-body antenna; SaR; wearable antenna; wideband antenna;
D O I
10.1109/aCCESS.2020.2967413
中图分类号
学科分类号
摘要
This paper presents a wideband, low-profile and semi-flexible antenna for wearable biomedical telemetry applications. The antenna is designed on a semi-flexible material of RT/duroid 5880 ( epsilon _{r} = 2.2 , tan delta = 0.0004 ) with an overall dimensions of 17 mm times25 mm times0.787 mm ( 0.2lambda _{circ }times 0.29lambda _{circ }times 0.009lambda _{circ } ). a conventional rectangular patch is modified by adding rectangular slots to lower the resonant frequency, and the partial ground plane is modified to enhance the operational bandwidth. The final antenna model operates at 2.4 GHz with a 10-dB bandwidth (fractional bandwidth) of 1380 MHz (59.7 % at the centre frequency of 2.4 GHz). The proposed antenna maintains high gain (2.50 dBi at 2.4 GHz) and efficiency (93 % at 2.4 GHz). It is proved from the simulations and experimental results that the antenna has negligible effects in terms of reflection coefficient, bandwidth, gain, and efficiency when it is bent. Moreover, the antenna is simulated and experimentally tested in proximity of the human body, which shows good performance. The proposed wideband antenna is a promising candidate for compact wearable biomedical devices. © 2013 IEEE.
引用
收藏
页码:15687 / 15694
页数:7
相关论文
共 50 条
  • [1] Wideband Wearable Antenna for Biomedical Telemetry Applications
    Smida, Amor
    Iqbal, Amjad
    Alazemi, Abdullah J.
    Waly, Mohamed I.
    Ghayoula, Ridha
    Kim, Sunghwan
    IEEE ACCESS, 2020, 8 : 15687 - 15694
  • [2] Novel implantable antenna with miniaturized footprint size for wideband biomedical telemetry applications
    Ahmad, Sarosh
    Manzoor, Bilal
    Shair, Muhammad Muzamil
    Khan, Shahid
    Akram, Ayesha
    Ghaffar, Adnan
    Al-Gburi, Ahmed Jamal Abdullah
    Ali, Esraa Mousa
    Arpanaei, Farhad
    Alibakhshikenari, Mohammad
    FREQUENZ, 2023, 77 (5-6) : 293 - 301
  • [3] MULTIBAND FLEXIBLE ULTRA-WIDEBAND ANTENNA FOR WEARABLE ELECTRONICS AND BIOMEDICAL APPLICATIONS
    Prasanna, R.
    Selvi, G. Thamarai
    Annaram, K.
    Venkatalakshmi, K.
    Jenath, M.
    Prathaban, Banu Priya
    INTERNATIONAL JOURNAL FOR MULTISCALE COMPUTATIONAL ENGINEERING, 2023, 21 (05) : 93 - 104
  • [4] A Multiband Flexible Wideband CPW Wearable Slot Antenna for Biomedical and IoT Applications
    Regulagadda N.R.
    Venkata Ratna Kumari U.
    Progress In Electromagnetics Research C, 2023, 135 : 131 - 144
  • [5] A Wideband Circularly Polarized Antenna With Metasurface Plane for Biomedical Telemetry
    Zhang, Kai
    Sarestoniemi, Mariella
    Myllymaki, Sami
    Soh, Ping Jack
    Chen, Juan
    Yan, Sen
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2024, 23 (06): : 1879 - 1883
  • [6] Performance of Wideband Falcate Implantable Patch Antenna for Biomedical Telemetry
    Singh, Raghvendra
    Jain, Love
    Rawat, Sanyog
    Ray, Kanad
    PROCEEDINGS OF FIFTH INTERNATIONAL CONFERENCE ON SOFT COMPUTING FOR PROBLEM SOLVING (SOCPROS 2015), VOL 2, 2016, 437 : 753 - 761
  • [7] A Wideband Multilayer Microstrip Patch Antenna for Telemetry Applications
    Hategekimana, Bazeyi
    Nithianandam, Jeyasingh
    PROCEEDINGS OF THE 8TH WSEAS INTERNATIONAL CONFERENCE ON DATA NETWORKS, COMMUNICATIONS, COMPUTERS (DNCOCO '09), 2009, : 250 - 254
  • [8] Miniaturized Dual-Wideband Circular Patch Antenna for Biomedical Telemetry
    Mohamed, AbdElrahman E.
    Sharawi, Mohammad S.
    2017 11TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2017, : 1027 - 1030
  • [9] Dual Band Implantable Antenna for Biomedical Telemetry Applications
    Konstantinos, Katsinos
    2020 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET): FOSTERING INNOVATION THROUGH ICTS FOR SUSTAINABLE SMART SOCIETY, 2020, : 253 - 256
  • [10] A Smart Wearable Textile Array System for Biomedical Telemetry Applications
    Soh, Ping Jack
    Van den Bergh, Bertold
    Xu, Hantao
    Aliakbarian, Hadi
    Farsi, Saeed
    Samal, Purna
    Vandenbosch, Guy A. E.
    Schreurs, Dominique M. M-P
    Nauwelaers, Bart K. J. C.
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (05) : 2253 - 2261