摘要
A mechanical model for the first fracture of main roof plate structure considering the elastic-plastic deformation of coal was established in this study.According to the finite difference principle and the fracturing criterion of main bending moment, the first fracture position and order of main roof plate structure with the elastic-plastic foundation boundary as well as the influencing factors and weight relationships of the fracture morphology characteristics in the whole region of main roof were systematically calculated and studied, and the engineering significance of the mechanical model was also expounded.The following conclusions were obtained based on the above research: ① When the main roof thickness h and elastic modulus E are relatively large, while the elastic coal foundation coefficient kt and the roof-hanging span of main roof are relatively small, the fracture position and order of main roof are illustrated as follows: the middle lower surface of roof in mining hanging roof area→the upper surface of roof ahead of the unplasticized elastic coal surface→the upper surface of roof along the short side of the stope ahead of the unplasticized elastic coal surface, and an O-type fracture circle will be formed in the roof on the elastic coal area.On the contrary, the fracture position and order of main roof are illustrated as follows: the upper surface of roof ahead of the plasticized coal surface→the middle lower surface of roof in mining hanging roof area→the upper surface of roof along the short side of the stope ahead of the plas-ticized coal surface, and an O-type fracture circle will be formed in the roof on the plasticized coal area.; Finally, the "O-X" type fracture shape is formed.② When the plasticized range of coal b0 and the plasticized degree of coal increase, the distance between the main roof fracture line ahead of the coal surface and the coal surface, and the absolute value of the main bending moment in each area of main roof will increase.That is, the roof-hanging span of main roof will decrease.③ When the plasticized range of coal b0 and the shallow plasticized coal foundation coefficient k0 are relatively large, the fracture position and order of main roof are illustrated as follows: the middle lower surface of roof in mining hanging roof area→the upper surface of roof along the long side of the stope ahead of the plasticized coal surface→the upper surface of roof along the short side of the stope ahead of the plasticized coal surface, and an O-type fracture circle will be formed in the roof on the plasticized coal area.When the values of b0 and k0 are relatively small, the fracture position and order of main roof are illustrated as follows: the upper surface of roof along the long side of the stope ahead of the elastic coal surface→the middle lower surface of roof in mining hanging roof area→the upper surface of roof along the short side of the stope ahead of the elastic coal surface, and an O-type fracture circle will be formed in the roof on the elastic coal area.Finally, the "O-X" type fracture shape is formed.④ When the ratio of k0 to kt is any constant value and the ratio of kt to h3 is also any constant value, the value and position of the main bending moment and the fracture law of main roof will remain unchanged. © 2020, Editorial Office of Journal of China Coal Society. All right reserved.
引用
收藏
页码:2704 / 2717
页数:13
相关论文
共 24 条
  • [1] (2013)
  • [2] WANG Hongsheng, ZHANG Dongsheng, LI Shugang, Et al., Rational width of narrow coal pillar based on the fracture line location of key rock B in main roof, Journal of Mining & Safety Engineering, 31, 1, pp. 10-16, (2014)
  • [3] HUANG Qingxiang, QI Wantao, YANG Chunlin, Analysis of the mechanism and shape of the first fracture of the main roof in the stope, Journal of Xi'an Institute of Mining, 3, pp. 193-197, (1999)
  • [4] HUANG Qingxiang, Structural analysis of the first fracture of the main in the stope, Journal of Rock Mechanics and Engineering, 17, 5, pp. 43-48, (1998)
  • [5] MA Qingyun, ZHAO Xiaodong, SONG Zhenqi, Break of main roof ahead of workface and ground pressure, Journal of China Coal Society, 26, 5, pp. 473-477, (2001)
  • [6] PAN Yue, GU Shitan, YANG Guanglin, Variation of internal force and rebound property of hard roof at initial stage of cracking, Chinese Journal of Geotechnical Engineering, 35, 7, pp. 860-869, (2015)
  • [7] (2009)
  • [8] WANG Jin'an, ZHANG Jiwei, GAO Xiaoming, Et al., Fracture mode and evolution of main roof stratum above longwall fully mechanized top coal caving in steeply inclined thick coal seam(I)-initial fracture, Journal of China Coal Society, 40, 6, pp. 1353-1360, (2015)
  • [9] ZHANG Yidong, ZHANG Chi, PAN Zhiqiang, Et al., Fracture mechanism analysis of main key layer of isolated island face based on plate model, Coal Engineering, 9, pp. 59-62, (2010)
  • [10] JIA Xirong, ZHAI Yingda, The review of groundpressure theory of thin slab in coal mining and its application, Ground Pressure and Strata Control, 16, 3, pp. 22-25, (1999)