Structure and Corrosion Resistance of Brazed Joint of Nuclear Grade 304L Stainless Steel

被引:0
|
作者
Yuan Y. [1 ]
Li S. [1 ]
Lyu Z. [2 ]
机构
[1] CNNC Jianzhong Nuclear Fuel Co., Ltd., Yibin
[2] School of Materials Science and Engineering, Shanghai University, Shanghai
来源
Yuanzineng Kexue Jishu/Atomic Energy Science and Technology | 2022年 / 56卷 / 07期
关键词
intergranular corrosion; nuclear grade 304L stainless steel; stress corrosion; vacuum brazing;
D O I
10.7538/yzk.2021.youxian.0485
中图分类号
学科分类号
摘要
The vacuum brazed joints of nuclear grade 304L stainless steel and BNi-7 filler metal show obvious intergranular corrosion behavior, but the relationship between the brazing process and the corrosion resistance of the brazed joint was not fully studied. In order to fully evaluate the sensitivity of intergranular corrosion and stress corrosion of stainless steel vacuum brazed joints of the structural parts of PWR fuel assemblies, and reduce the risk of corrosion failure, many trials and studies were conducted. In this paper, the quantitative metallographic method was used to analyze the content of the compound phase content of brazed joints by different brazing processes. The sulfuric acid-ferric sulfate test method and the double loop electrochemical potentiokinetic reaction (DL-EPR) test method were used to test the intergranular corrosion resistance. The high-temperature and high-pressure water stress corrosion crack growth tests were used to study the stress corrosion resistance of brazed joints, respectively. The results show that increasing the brazing temperature, prolonging the holding time and decreasing the clearance of the brazed joints can reduce the content of the compound phase content in the brazed joint. This might be related to the increase in diffusion of P element. But meanwhile, with the reduction of the compound phase, the intergranular corrosion rate will also significantly increase. Metallographic photographs show that all the corrosions are caused in the nickel-based solid solution phase of the brazed joint. Both the sulfate-ferric sulfate test method and the DL-EPR test method show such a trend. Firstly, the stress corrosion cracking behavior in high-temperature and high-pressure water was also confirmed by the high-temperature and high-pressure water stress corrosion crack growth tests. But the relationship with the brazing process needs further experimental research. Therefore, under the condition of ensuring the strength of the brazed joint, the brazing temperature should be increased, the holding time should be extended and the clearance of the brazed joints should be reduced to reduce the compound phase content, thereby increasing the content of nickel-based solid solutions in the brazed joints and reducing the tendency to the intergranular corrosion. In addition, within the range of test parameters, the obvious tendency to intergranular corrosion in all the brazed joints was observed. The lower the compound phase content in the brazed joints, the more obvious the intergranular corrosion tendency, which is related to the fact that intergranular corrosion is mainly caused by the dissolution of the solid solution phase of the lean Cr. This study also confirmed that there is a stress corrosion tendency of brazed joints in the PWR water environment, and the area where stress corrosion is generated is mainly the solid solution phase. But the correlation between the degree of stress corrosion and the brazing process needs to be further studied. © 2022 Atomic Energy Press. All rights reserved.
引用
收藏
页码:1395 / 1401
页数:6
相关论文
共 16 条
  • [1] JIAO Yongjun, XIAO Zhong, LI Yun, Et al., R&D and validation of HPR1000 fuel assembly, China Nuclear Power, 10, 4, pp. 478-482, (2017)
  • [2] (2012)
  • [3] (1993)
  • [4] CHEN Jianmin, ZHU Changfu, Investigation of the microstructure of stainless steel joint brazed in vacuum, Journal of China University of Petroleum: Edition of Natural Science, 15, 2, pp. 66-68, (1999)
  • [5] JING Jingnan, YU Zhishui, CHANG Wenlong, Et al., Microstructure and microhardness of 316L stainless steel joint seam vacuum brazed by BNi7 Ni-based filler metal, Materials for Mechancial and Engineering, 37, 1, pp. 10-13, (2013)
  • [6] CHEN Furong, LIU Jun, DONG Junhui, Et al., Microstructure and mechanical properties of vacuum brazed joints of 1Cr18Ni9Ti stainless steel, Welding & Joining, 6, pp. 18-21, (2004)
  • [7] (2015)
  • [8] ZHANG Weijie, LI Wenqing, The stress-corrosion behavior in water media containing chlorine of the brazing joint of grids for PWR fuel element, Nuclear Power Engineering, 6, 5, pp. 14-17, (1985)
  • [9] (2004)
  • [10] YUAN Ye, ZHOU Xi, LI Sha, Experimental study on intergranular corrosion resistance of 304L stainless steel vacuum brazed joints, Hot Working Technology, 50, 11, pp. 63-66, (2021)