Enhancing energy conservation in power generation in a coal fired thermal power plant through comprehensive energy audit

被引:1
作者
Thakare, Hitesh R. [1 ]
Daspute, Pramod [2 ]
机构
[1] BEE Certified Energy Auditor EA 27707, SVKMs Inst Technol, Dept Mech Engn, Dhule 424001, Maharashtra, India
[2] BEE Certified Energy Auditor EA 6453, Energy Consultant, C4-703,Madhav Srishti,Khadak Pada,Kalyan West, Thana 421301, Maharashtra, India
关键词
Energy audit; Thermal power plant; Variable frequency drive; APH leakage; Insulation; EFFICIENCY;
D O I
10.1016/j.energy.2024.131661
中图分类号
O414.1 [热力学];
学科分类号
摘要
Current work presents salient insights from energy audit of a 1050 MW thermal power plant by BEE Certified Energy Auditors. It provides insights into grassroot level data instead of relying only on theoretical calculations, unlike previously published literature. Arresting the air leakages in air-preheater has given total saving of 10.72 million kWh/year, saved 398,978.97 kJ/year, thus saving of 25,322.80 MT of coal/year. Upgradation of insulation resulted in total saving of 6632.208 Million kJ/year, i.e. saving of 510 MT/year of coal. Replacing cooling tower blades material proposed saving of 15,242.4 kWh/year. Installation of Variable Speed Drives for pumps provided saving of 274,836 kWh/year. Replacement of old inefficient pumps with energy efficient pumps has saving potential of 739,632 kWh/year. Pressure reduction in compressors has given saving of 344,794 kWh/year. Thus, in total, this energy audit helped to conserve 12.098 Million kWh & 25,832.80 MT coal/year and consequently, 104,243 tCO2/year. 2 /year. Such savings not only help the plant management/decision makers on the monetary front but also identify the avenues for improvement and channelize the resources such time and investment, prudently. Consequently, it has been established that energy audit is a pragmatic tool to achieve energy conservation at grassroot level.
引用
收藏
页数:17
相关论文
共 30 条
[1]  
Ab Halim M.F.M., 2019, Int J Electr Comput Eng, V9, P1569, DOI [10.11591/ijece.v9i3.pp1569-1575, DOI 10.11591/IJECE.V9I3]
[2]   Energy saving potential analysis applying factory scale energy audit-A case study of food production [J].
Al Momani, Derar ;
Al Turk, Yousef ;
Abuashour, Mohammed I. ;
Khalid, Haris M. ;
Muyeen, S. M. ;
Sweidan, Tha'er O. ;
Said, Zafar ;
Hasanuzzaman, M. .
HELIYON, 2023, 9 (03)
[3]   Maximum Demand Management: An overlooked energy saving opportunity in industries [J].
Ayyappan, Preethy ;
Kumar, Jeyanandan ;
Venkiteswaran, Vinod Kumar .
INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND GREEN TECHNOLOGY 2018, 2019, 268
[4]  
Bajwa M, 2011, Int J Mech Eng Technol, V2, P111
[5]   Energy audit, techno-economic, and environmental assessment of integrating solar technologies for energy management in a university residential building: A case study [J].
Bosu, Issa ;
Mahmoud, Hatem ;
Hassan, Hamdy .
APPLIED ENERGY, 2023, 341
[6]   From Energy Audit to Energy Performance Indicators (EnPI): A Methodology to Characterize Productive Sectors. The Italian Cement Industry Case Study [J].
Bruni, Giacomo ;
De Santis, Alessandra ;
Herce, Carlos ;
Leto, Luigi ;
Martini, Chiara ;
Martini, Fabrizio ;
Salvio, Marcello ;
Tocchetti, Federico Alberto ;
Toro, Claudia .
ENERGIES, 2021, 14 (24)
[7]   Parametric identification of integrated model of a coal-fired boiler in a thermal power plant [J].
Chandrasekharan, Sreepradha ;
Panda, Rames C. ;
Swaminathan, Bhuvaneswari Natrajan ;
Panda, Atanu ;
Thyagarajan, T. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2020, 234 (04) :520-533
[8]  
Das S, 2015, World Sci News, V22, P70
[9]  
Dhanre GT., 2014, INT J ENG RES GEN SC, V2, P283
[10]  
Domingo ET, 2023, Indones J Electr Eng Comput Sci, V30, ppp1279, DOI [10.11591/ijeecs.v30.i3, DOI 10.11591/IJEECS.V30.I3]