Research on synthetic aperture focusing ultrasonic imaging based on phase coherence in frequency domain

被引:0
|
作者
Mao Q. [1 ]
Chen Y. [1 ,2 ]
Shi W. [1 ]
Lu C. [1 ,3 ]
Li Q. [1 ]
机构
[1] Key Laboratory of Non-destructive Testing Technology, Nanchang Hangkong University, Nanchang
[2] State Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing
[3] Gannan Normal University, Ganzhou
关键词
Frequency domain; Phase circular statistics vector; Synthetic aperture focusing technique (SAFT); Ultrasonic;
D O I
10.19650/j.cnki.cjsi.J1905868
中图分类号
学科分类号
摘要
In order to improve the imaging quality and efficiency of synthetic aperture focusing technique (SAFT), a frequency domain SAFT ultrasonic imaging algorithm based on phase circular statistics vector (PCSV) is proposed. Firstly, the Hilbert transform and Euler's formula are used to extract the instantaneous phase of the signals in wave field record. Secondly, the real part and imaginary part of the instantaneous phase are regarded as the PCSVs distributed in circular complex plane, and through wave field extrapolation, the phase coherence factor used for frequency domain SAFT weighting is constructed. Finally, the high quality frequency domain SAFT-PCSV image is obtained through weighting processing. The imaging results show that the frequency-domain SAFT-PCSV imaging algorithm effectively enhances the image resolution and signal-to-noise ratio. Under the same test conditions, the operational time and occupied memory space of the frequency-domain SAFT-PCSV imaging algorithm are less than 1/46, and 1/47 of those of traditional time-domain SAFT algorithm, respectively. © 2020, Science Press. All right reserved.
引用
收藏
页码:135 / 145
页数:10
相关论文
共 27 条
  • [1] Zhou Z.G., Li Y., Zhou W.B., Et al., Ultrasonic phased array post-processing imaging techniques: A review, Journal of Mechanical Engineering, 52, 6, pp. 1-11, (2016)
  • [2] Fu Z.K., Shi L.H., Fu S.C., Et al., SAFT imaging method for concrete blocks based on amplitude compensation, Journal of Nanjing University of Aeronautics & Astronautics, 49, 4, pp. 540-547, (2017)
  • [3] Wu W.T., Pu J., Lyu Y., Medical ultrasound imaging method combining minimum variance beaming and general coherence factor, Acta Acustica, 36, 1, pp. 66-72, (2011)
  • [4] Yang Y., Ultrasonic imaging methods of wheels detection based on synthetic aperture focusing technique, (2014)
  • [5] Li P.C., Li M.L., Adaptive imaging using the generalized coherence factor, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 50, 2, pp. 128-141, (2003)
  • [6] Zheng C.C., Cheng J., Peng H., Ultrasonic synthetic aperture imaging algorithm based on power sample entropy as adaptive weight, Acta Acustica, 42, 1, pp. 109-114, (2017)
  • [7] He Q., Wang Y.Z., Zheng C.C., Et al., Ultrasound virtual source imaging weighted by generalcoherence factor weighting, Journal of Biomedical Engineering Research, 38, 3, pp. 341-346, (2019)
  • [8] Zheng C.C., Peng H., Zhao W., Ultrasound imaging based on coherent plane wave compounding weighted by sign coherence factor, Acta Electronica Sinica, 46, 1, pp. 31-38, (2018)
  • [9] Wang L., Chen G., Shi W.Z., Et al., Research on defect image enhancement of circumferential piezoelectric lamb wave in thick-walled pipelines, Piezoelectric & Acoustooptics, 40, 6, pp. 46-50, (2018)
  • [10] Chen Y., Mao Q.Q., Shi W.Z., Et al., Research on ultrasonic TOFD imaging inspection for heavy-walled weld based on phase coherence characteristics, Journal of Mechanical Engineering, 55, 4, pp. 25-32, (2019)