A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma

被引:0
|
作者
Eldebawy E. [1 ,2 ]
Rashed Y.A. [2 ,3 ,4 ]
AlKhaldi M. [2 ,5 ]
Day E. [2 ,6 ]
机构
[1] Consultant of Radiation Oncology, National Cancer Institute, Cairo University
[2] King Fahad Specialist Hospital, Dammam
[3] Medical Physics Dept., Faculty of Medicine, Menofiya University
[4] Consultant of Radiation Oncology Physics, King Fahad Specialist Hospital, Dammam
[5] Medical Physicist (Radiation Oncology Physics), Radiation Oncology Department, Medical Physics Unit, King Fahad Specialist Hospital, Dammam
[6] Radiation Therapist, King Fahad Specialist Hospital, Dammam
关键词
Rectal Cancer VMAT Intensity Modulated Dosimetry Comparison;
D O I
10.22038/ijmp.2019.42941.1652
中图分类号
学科分类号
摘要
Introduction: The study was conducted to compare volumetric-modulated arc therapy (VMAT) with intensity-modulated radiation therapy (IMRT) in patients with locally advanced rectal cancer (LARC). Material and Methods: Ten computed tomography (CT) scans were selected and for each CT scan, two plans were created (IMRT and VMAT). The average cumulative dose-volume histograms (DVH) of VMAT plans for the planning target volumes (PTVs), organs at risk (OARs), and normal tissues were calculated and compared with those reported for the corresponding IMRT technique. Results: Target coverage was equivalent for both techniques. For primary PTV, the average homogeneity index (HI) of IMRT was significantly lower than the VMAT plans (0.10±0.04 vs. 0.11±0.03; P<0.0001). The average conformity index (CI) values for IMRT and VMAT were 1.21 and 1.12, respectively, with a nonsignificant trend for better results with VMAT (P=0.1). For the PTV boost, there was a nonsignificant trend for better results with VMAT in average HI and CI. The VMAT was superior to IMRT in OAR sparing. For monitor units (MUs), VMAT plans required 70% less MUs than IMRT. Conclusion: For LARC patients, VMAT was able to deliver treatment plans dosimetrically equivalent to IMRT in terms of PTV coverage. The VMAT provided better OAR sparing and significant reduction of MUs in comparison to IMRT. © 2020. All Rights Reserved.
引用
收藏
页码:374 / 379
页数:5
相关论文
共 50 条
  • [21] Dosimetric Comparison of Automated Non-Coplanar Volumetric-Modulated Arc Therapy and Intensity-Modulated Proton Therapy in Angiosarcoma of the Scalp
    Inui, S.
    Tomita, N.
    Takaoka, T.
    Ueda, Y.
    Ohira, S.
    Tsuchiya, T.
    Miyazaki, M.
    Nishio, T.
    Koizumi, M.
    Konishi, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E675 - E675
  • [22] Dosimetric Comparison of the Newest Version Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy Plans for Angiosarcoma of the Scalp
    Mizuno, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E10 - E10
  • [23] Dosimetric benefits of intensity-modulated radiotherapy and volumetric-modulated arc therapy in the treatment of postoperative cervical cancer patients
    Deng, Xia
    Han, Ce
    Chen, Shan
    Xie, Congying
    Yi, Jinling
    Zhou, Yongqiang
    Zheng, Xiaomin
    Deng, Zhenxiang
    Jin, Xiance
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (01): : 25 - 31
  • [24] Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation-A comparison with traditional techniques
    Studenski, Matthew T.
    Shen, Xinglei
    Yu, Yan
    Xiao, Ying
    Shi, Wenyin
    Biswas, Tithi
    Werner-Wasik, Maria
    Harrison, Amy S.
    MEDICAL DOSIMETRY, 2013, 38 (01) : 48 - 54
  • [25] Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots
    Tran Thi Thao Nguyen
    Hidetaka Arimura
    Ryosuke Asamura
    Taka-aki Hirose
    Saiji Ohga
    Jun-ichi Fukunaga
    Radiological Physics and Technology, 2019, 12 : 137 - 148
  • [26] Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots
    Tran Thi Thao Nguyen
    Arimura, Hidetaka
    Asamura, Ryosuke
    Hirose, Taka-aki
    Ohga, Saiji
    Fukunaga, Jun-ichi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (02) : 137 - 148
  • [27] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy For Liver Carcinoma
    Chiang, B.
    Schnell, E.
    Hibbitts, K.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E750 - E750
  • [28] Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels
    Onal, Cem
    ArsIan, Gungor
    Dolek, Yemliha
    Efe, Esma
    Medical Dosimetry, 2016, 41 (04) : 310 - 314
  • [29] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for liver stereotactic ablative body radiotherapy
    Thibault, Isabelle
    Wronski, Matt
    Korol, Renee
    Chu, William
    Helou, Joelle
    Erler, Darby
    Chung, Hans T.
    JOURNAL OF RADIATION ONCOLOGY, 2016, 5 (01) : 63 - 69
  • [30] Dosimetric comparison of volumetric modulated arc therapy and intensity modulated radiation therapy for anal cancer
    Chiang, Bing-Hao
    Hibbitts, Kerry
    Ortega, Heather
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 190 - 192