Investigating the Overhead Line Caused Harmonic Induction on Pipeline: Evaluation Method and Impact Factors

被引:0
|
作者
Yong J. [1 ]
Zhu Z. [1 ]
Wang X. [1 ]
机构
[1] State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing
基金
中国国家自然科学基金;
关键词
AC induction; Harmonic; Induced voltage; Metallic pipeline; Overhead power line;
D O I
10.13334/j.0258-8013.pcsee.200149
中图分类号
学科分类号
摘要
The harmonic induction on the metallic pipeline caused by AC overhead power lines in the common corridor is not clear yet. Through massive CDEGS simulations, this paper confirmed that the traditional circuit-based method used for assessing pipeline induction caused by fundament frequency current could be applied to harmonic induction assessment, provided that the Carson's and Sunde's formulae were used for calculation of mutual impedance between pipeline and power lines, and self-impedance/admittance of pipeline, respectively. The investigations on the impact factors of pipeline induction were conducted, which led to the following findings: The harmonic induction on the pipeline caused harmonic currents may be more significant than that caused by fundament currents. The soil resistivity was more sensitive to the harmonic frequency induction. The field measurements also verified the proposed method and demonstrated that the harmonic induction indeed existed in the real pipeline system and the harmonic induction was much severer than fundamental frequency induction in this case. © 2021 Chin. Soc. for Elec. Eng.
引用
收藏
页码:3130 / 3138
页数:8
相关论文
共 21 条
  • [1] ZAKIKHANI K, NASIRI F, ZAYED T., A review of failure prediction models for oil and gas pipelines, Journal of Pipeline Systems Engineering and Practice, 11, 1, (2020)
  • [2] CHRISTOFORIDIS G C, LABRIDIS D P, DOKOPOULOS P S., Inductive interference on pipelines buried in multilayer soil due to magnetic fields from nearby faulted power lines, IEEE Transactions on Electromagnetic Compatibility, 47, 2, pp. 254-262, (2005)
  • [3] QI Lei, BAI Shuhua, YUAN Hui, Et al., Earth return impedance and admittance of overhead line-underground cable systems, Proceedings of the CSEE, 32, 33, pp. 148-156, (2012)
  • [4] MENG Xiaobo, ZHANG Bo, LIAO Yongli, Et al., Potential influence of ground return current from HVDC grounding electrode on buried pipeline, Proceedings of the CSEE, 39, 20, pp. 6113-6121, (2019)
  • [5] WU Xuan, ZHANG Hui, KARADY G G., Transient analysis of inductive induced voltage between power line and nearby pipeline, International Journal of Electrical Power & Energy Systems, 84, pp. 47-54, (2017)
  • [6] KOROVKIN N, GONCHAROV V., Calculation of induced EMF by overhead lines, Proceedings of 2016 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference, pp. 608-610, (2016)
  • [7] Guide on the influence of high voltage AC power systems on metallic pipelines, (1995)
  • [8] PAGANO M A, LALVANI S B., Corrosion of mild steel subjected to alternating voltages in seawater, Corrosion Science, 36, 1, pp. 127-140, (1994)
  • [9] TANG Kangkang, Stray alternating current (AC) induced corrosion of steel fibre reinforced concrete, Corrosion Science, 152, pp. 153-171, (2019)
  • [10] GUO Yanbao, MENG Tao, WANG Deguo, Et al., Experimental research on the corrosion of X series pipeline steels under alternating current interference, Engineering Failure Analysis, 78, pp. 87-98, (2017)