Experimental study on restoring force characteristics of column rocking with horizontal cross members and varying axial force

被引:0
作者
Takino A. [1 ]
Mukaibo K. [2 ]
Araki Y. [3 ]
Miyamoto Y. [4 ]
Isoda H. [5 ]
Kawai N. [6 ]
机构
[1] Nara Womens University, Japan
[2] Tottori University, Japan
[3] National Institute for Land and Infrastructure Management
[4] Osaka University, Japan
[5] Kyoto University, Japan
[6] Kogakuin University, Japan
来源
Journal of Structural and Construction Engineering | 2020年 / 85卷 / 771期
关键词
Column rocking; Embedment of wood; Horizontal cross member; Japanese traditional construction method; Varying axial force;
D O I
10.3130/aijs.85.715
中图分类号
TU [建筑科学]; TV [水利工程];
学科分类号
0813 ; 0815 ;
摘要
In this study, we conducted the experiments of the restoring force characteristics of column rocking found in the temple buildings using large diameter columns on the basis of the Japanese traditional construction methods, and especially experimental verification was conducted on the effects of varying axial force and the horizontal cross members, because experiments with these parameters had not been examined so far. As the results, it was clarified that the restoring force of the specimen with the horizontal cross members was significantly reduced as compared with the existing evaluation formula. © 2020 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:715 / 723
页数:8
相关论文
共 16 条
[1]  
Ban Shizuo, Study on statics for structures of temple and shrine Part-1, Transactions of the Institute of Japanese Architects, 21, pp. 252-258, (1941)
[2]  
Kawai Naohito, A series of experiments on restoring force produced by rocking of wooden column, Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structures-II, pp. 91-92, (1991)
[3]  
Kawai Naohito, Full-scale tests on restoring force of traditional wooden buildings produced by rocking of column and bearing wall, Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structures-II, pp. 1021-1022, (1993)
[4]  
Kawai Naohito, Column rocking resistance in Japanese traditional timber buildings, Proceedings of the international wood engineering conference, pp. 183-190, (1996)
[5]  
Kawai Naohito, Static loading test on column rocking resistance using scale models, Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structures-III, pp. 529-530, (2017)
[6]  
Kawai Naohito, Static loading test on column rocking resistance using scale models Part2 Influence of column section shape and theoretical solution considering initial deformation, Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structures-III, pp. 183-184, (2018)
[7]  
Editorial board of seismic design manual for wooden post-and-beam construction building: Seismic design manual for wooden post-and-beam construction building based on traditional construction method Gaku ei Shu an-Sha, (2004)
[8]  
Agency for Cultural Affairs: Implementation Guidance for Basic Seismic Assessment of Important Cultural Properties (Buildings), (2012)
[9]  
Maeno Masaki, Saito Sumito, Suzuki Yoshiyuki, Evaluation of equilibrium of force acting on column and restoring force due to column rocking by full-scale tests of traditional wooden frames, Journal of Structural and Construction Engineering (Transactions of AIJ), 615, pp. 153-160, (2007)
[10]  
Saburi Kazuhiro, Nagase Tadashi, Structural Analysis of Rocking Column in Japanese Traditional Wooden Buildings, SSummaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structures-III, pp. 143-144, (2000)