A consideration on maximum efficiency of resonant circuit of inductive power transfer system with soft-switching operation

被引:0
|
作者
Ota R. [1 ,2 ]
Nugroho D.S. [1 ]
Hoshi N. [1 ]
机构
[1] Department of Electrical Engineering, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda-city, Chiba
[2] JSPS Research Fellow (PD), Japan Society for the Promotion of Science, Sumitomo-Ichibancho Bldg., 6 Ichibancho, Chiyoda-ku, Tokyo
基金
日本学术振兴会;
关键词
Battery charger; Bi-directional; Electric vehicles; Improving efficiency; Inductive power transfer (IPT); Maximum efficiency; Soft switching; Wireless power transfer; Zero voltage switching (ZVS);
D O I
10.3390/wevj10030054
中图分类号
学科分类号
摘要
By using bi-directional inductive power transfer (IPT) systems as battery chargers for electric vehicles (EVs), battery charging operations become convenient and safe. However, IPT systems have problems such as occurrences of much electromagnetic noise and power loss because the converters of IPT systems are driven in high frequency by tens of kHz. To solve these problems, there is a case where the soft-switching technique needs to be applied to the converters of IPT systems. However, in soft-switching operation, the power factor of the resonant circuit becomes lower, resulting in a lower resonant circuit efficiency. In previous works, when the soft-switching technique was applied to the converters, the resonant circuit had not always been able to be operated with high efficiency because the influence caused by soft-switching operation had not been considered. For this reason, there was a case where the efficiency of the overall system with soft-switching operation became lower than the efficiency in hard-switching operation. Therefore, in this paper, the influence on the efficiency of the resonant circuit caused by the soft-switching operation is clarified by the theoretical analysis and experiments; then, the guideline for improving the efficiency of IPT systems is shown. As a result, in the experiments, it could be understood that the efficiency of the overall system with soft-switching operation becomes higher than the efficiency in hard-switching operation when the operating point of the resonant circuit was close to the requirement guideline, which is shown by using the primary-side voltage and the secondary-side voltage of the resonant circuit. Therefore, it is suggested that the efficiency of IPT systems could be improved by properly regulating the primary-side direct current (DC) voltage. © 2019 by the authors.
引用
收藏
相关论文
共 50 条
  • [1] A new circuit of soft-switching inductive power transfer system
    Chongqing University, Chongqing 400030, China
    Sun, Y., 1600, China Machine Press (28):
  • [2] Soft-switching Converter for Inductive Power Transfer System with Double-sided LCC Resonant Network
    Okada, Ryohei
    Ota, Ryosuke
    Hoshi, Nobukazu
    2022 24TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'22 ECCE EUROPE), 2022,
  • [3] A Full Load Range Soft-Switching Inductive Power Transfer System
    Li, Xin
    Tang, Yi
    Zhang, Yiming
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [4] Maximum Efficiency Control Scheme and Design Method for Resonant Circuit of Bi-directional Inductive Power Transfer System
    Ota, Ryosuke
    Kakomura, Kengo
    Hoshi, Nobukazu
    Sato, Daiki
    2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [5] Soft-Switching Boost Converter with an Auxiliary Resonant Circuit
    Bano, Mumtaz Jabeen
    Kowser, Farha
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 418 - 425
  • [6] Consideration of operating condition of secondary-side converter of inductive power transfer system for obtaining high resonant circuit efficiency
    Takuzaki, K. (takuzaki@hoshilab.ee.noda.tus.ac.jp), 1600, Institute of Electrical Engineers of Japan (132):
  • [7] A Systematic Comparison of Hard- and Soft-Switching Topologies for Inductive Power Transfer Systems
    Diekhans, Tobias
    Stewing, Felix
    Engelmann, Georges
    van Hoek, Hauke
    De Doncker, Rik W.
    2014 4TH INTERNATIONAL ELECTRIC DRIVES PRODUCTION CONFERENCE (EDPC), 2014, : 362 - 369
  • [8] Novel Soft-Switching Active-Bridge Converter for Bi-directional Inductive Power Transfer System
    Okada, Ryohei
    Ota, Ryosuke
    Hoshi, Nobukazu
    IEEJ JOURNAL OF INDUSTRY APPLICATIONS, 2022, 11 (01) : 97 - 107
  • [9] A Consideration on Efficiency Maximization for Inductive Power Transfer System with Dual Converters
    Okada, Ryohei
    Ota, Ryosuke
    Hoshi, Nobukazu
    2022 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-HIMEJI 2022- ECCE ASIA), 2022, : 2057 - 2064
  • [10] An Active-Rectification Based Communication Free Inductive Power Transfer for Battery Charging System with Soft-Switching Capability
    Dou, Yi
    Liu, Yunfeng
    Huang, Xiaosheng
    Ouyang, Ziwei
    Andersen, Michael A. E.
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 1627 - 1633