Microstructural and electrochemical properties of TiAlN(Ag,Cu) nanocomposite coatings for medical applications deposited by DC magnetron sputtering

被引:33
作者
Mejía H.D.V. [1 ]
Echavarría A.M. [1 ]
Calderón J.A. [1 ]
Gilberto Bejarano G. [1 ]
机构
[1] Centro de Investigación, Innovación y Desarrollo de Materiales – CIDEMAT, Universidad de Antioquia, Calle 70 N° 52–21, Medellín
关键词
Ag–Cu nanoparticles; Corrosion resistance; Doped TiAlN; Electrochemical behavior; Magnetron sputtering; Nanocomposite coatings;
D O I
10.1016/j.jallcom.2020.154396
中图分类号
学科分类号
摘要
AISI 420 stainless steel is currently used in the manufacture of surgical and dental instrumentation due to its hardenability, acceptable biocompatibility and resistance to corrosion. However, its resistance to wear is relatively low, and therefore multiple strategies of surface modification are used in order to overcome these drawbacks in the properties of this material when envisaging its use for biomedical applications. In this work, TiAlN coatings doped with Ag and Cu nanoparticles in four different quantities (11 at.% to 20 at.%) were deposited onto 420 steel by DC magnetron sputtering technique. The microstructure, and chemical and phase composition were analyzed by scanning and transmission electron microscopy (SEM/TEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction, while roughness was determined using atomic force microscopy (AFM). The electrochemical behavior of the coatings was evaluated by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization. The analysis of the microstructures of the different coatings revealed that the typical columnar structure of the TiAlN matrix is densified as the content of silver and copper increases. The Ag and Cu doping materials are placed in the free spaces between the grain limits of the TiAlN structure due to their insolubility in the ceramic matrix. Additionally, a concomitant increase in the amount and size of the Ag and Cu nanoparticles present on the coating surface was evidenced as the power applied to the target was raised. A reduction in the corrosion current density of the steel substrate was evident once it was superficially modified with the TiAlN matrix coating, which formed a protective barrier to the corrosive medium. The TiAlN(Ag,Cu) coatings developed superior electrochemical activity with respect to the TiAlN matrix, and consequently exhibited higher corrosion current densities. This behavior was accentuated with increased Ag/Cu content in the coating, and it was correlated mainly with the increase in the dissolution rates of silver and copper to the surrounding medium. This suggests a potential bactericidal effect of this kind of coating, which might be considered for potential application in surgical and dental instrumentation. © 2020
引用
收藏
相关论文
共 55 条
[1]  
Metals A.S., Stainless Steel Bar., 420, (2006)
[2]  
Mainier F.B., Lopes M.M.C., Tavares S.S.M., Pardal J.M., Corrosion in surgical instruments, IOSR J. Eng., 3, pp. 25-31, (2013)
[3]  
Hashizume T., Saiki A., Terayama K., TaN thin film fabricated by the magnetron sputtering with medium vacuum, J. Australas. Ceram. Soc., 49, pp. 76-78, (2013)
[4]  
Quirama A., Echavarria A.M., Meza J.M., Osorio J., Bejarano G G., Improvement of the mechanical behavior of the calcium phosphate coatings deposited onto Ti6Al4V alloy using an intermediate TiN/TiO2 bilayer, Vacuum, 146, (2017)
[5]  
Souto R.M., Alanyali H., Electrochemical characteristics of steel coated with TiN and TiA1N coatings, Corrosion Sci., 42, pp. 2201-2211, (2000)
[6]  
Liscano S., Gil L., Leon O.A., Cruz M., Staia M.H., Corrosion performance of duplex treatments based on plasma nitriding and PAPVD TiAlN coating, Surf. Coating. Technol., 201, pp. 4419-4423, (2006)
[7]  
Bolivar Osorio F.J., Gomez M., Bejarano G., Influence of the duplex coatings on the mechanical properties and wear resistance of the tempered AISI 4140 steel, Esc. Ing. Antioquía., 10-19, pp. 151-160, (2013)
[8]  
Correa F., Aperador W., Bejarano G., Mejoramiento de la resistencia a la corrosión del acero AISI 4140 utilizando multicapas de titanio/nitruro de titanio Corrosion resistance improvement of steel AISI 4140 by using a titanium/titanium nitride multilayer coating system, Fac.Ing.Univ.Antioquia., pp. 7-14, (2008)
[9]  
Bull S.J., Jones A.M., Multilayer coatings for improved performance, Surf. Coating. Technol., 78, pp. 173-184, (1996)
[10]  
Li R., Wang C., G.X X., Y.L, T.H, Effects of different sterilization methods on the corrosion of dental fissure bur, US Natl. Libr. Med. Natl. Institutes Heal., 25, (2007)