Molecular diagnostics for clinical respiratory virus on a total integrated centrifugal microsystem using reverse transcription-loop-mediated isothermal amplification

被引:7
|
作者
Phan V.M. [1 ]
Kang S.W. [2 ]
Kim Y.H. [2 ]
Lee M.Y. [3 ]
Nguyen H.V. [1 ]
Jeon Y.L. [4 ]
Lee W.I. [3 ]
Seo T.S. [1 ]
机构
[1] Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin
[2] Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kyung Hee University Hospital at Gangdong, College of Medicine, Kyung Hee University, Seoul
[3] Department of Laboratory Medicine, Kyung Hee University College of Medicine, Kyung Hee University Hospital at Gangdong, Seoul
[4] Department of Laboratory Medicine, Green Cross Laboratories, Yongin-si
基金
新加坡国家研究基金会;
关键词
Centrifugal microfluidics; COVID-19; Loop-mediated isothermal amplification; Point-of-care; Respiratory virus;
D O I
10.1016/j.snb.2023.133962
中图分类号
学科分类号
摘要
Respiratory viruses are highly contagious agents that can cause endemic and epidemic infections in humans. Early detection of these viruses is crucial in preventing economic damage and reducing mortality rates. In this study, we present a total integrated genetic analyzer to perform a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay for the simultaneous detection of 7 respiratory viruses (Influenza A H1N1 and H3N2, Influenza B, Respiratory syncytial virus A and B, Adenovirus, and COVID-19). The primer sets for the RT-LAMP assay were designed and evaluated in comparison with the RT-PCR assay using clinical samples, confirming high specificity and efficiency. The entire process of viral RNA extraction, reagent mixing, gene amplification, and detection was completed on the device in 1 hr 20 min. The constructed portable diagnostic instrument is equipped with a rotary motor, two sets of peltier heaters, a fluorescence detector, and a touch screen for inputting experimental parameters and displaying result. The proposed point-of-care (POC) diagnostic platform correctly analyzed a total of 21 clinical samples (3 for each of the 7 viruses). The limit-of-detection (LOD) for Influenza A subtype H3N2 was 101 pfu/mL, which demonstrates the high performance of our proposed centrifugal microsystem for on-site molecular diagnostics in medical centers. © 2023 Elsevier B.V.
引用
收藏
相关论文
共 50 条
  • [31] A simple colorimetric detection of porcine epidemic diarrhea virus by reverse transcription loop-mediated isothermal amplification assay using hydroxynaphthol blue metal indicator
    Kim, Jae-Kyeom
    Kim, Hye-Ryung
    Kim, Da-Young
    Kim, Jong-Min
    Kwon, Na-Young
    Park, Ji-Hoon
    Park, Ji-Young
    Kim, Seong-Hee
    Lee, Kyoung-Ki
    Lee, Changhee
    Joo, Hoo-Don
    Lyoo, Young S.
    Park, Choi-Kyu
    JOURNAL OF VIROLOGICAL METHODS, 2021, 298
  • [32] Rapid and sensitive detection of type II porcine reproductive and respiratory syndrome virus by reverse transcription loop-mediated isothermal amplification combined with a vertical flow visualization strip
    Gou, Hongchao
    Deng, Jieru
    Pei, Jingjing
    Wang, Jiaying
    Liu, Wenjun
    Zhao, Mingqiu
    Chen, Jinding
    JOURNAL OF VIROLOGICAL METHODS, 2014, 209 : 86 - 94
  • [33] Rapid Detection of Avian Infectious Bronchitis Virus by Reverse Transcriptase-Loop Mediated Isothermal Amplification
    Chandrasekar A.
    Raja A.
    Dhinakar Raj G.
    Thangavelu A.
    Kumanan K.
    Proceedings of the National Academy of Sciences, India Section B: Biological Sciences, 2015, 85 (3) : 815 - 820
  • [34] Portable Molecular Diagnostics Device for Identification of Asini Corii Colla by Loop-Mediated Isothermal Amplification
    Sheu, Shyangchwen
    Huang, Chungyu
    Chen, Jyhjian
    INVENTIONS, 2021, 6 (03)
  • [35] Rapid and reliable diagnostic method to detect Zika virus by real-time fluorescence reverse transcription loop-mediated isothermal amplification
    Xu-Guang Guo
    Yong-Zhuo Zhou
    Qin Li
    Wei Wang
    Jin-Zhou Wen
    Lei Zheng
    Qian Wang
    AMB Express, 8
  • [36] Rapid and reliable diagnostic method to detect Zika virus by real-time fluorescence reverse transcription loop-mediated isothermal amplification
    Guo, Xu-Guang
    Zhou, Yong-Zhuo
    Li, Qin
    Wang, Wei
    Wen, Jin-Zhou
    Zheng, Lei
    Wang, Qian
    AMB EXPRESS, 2018, 8
  • [37] Use of reverse transcription loop-mediated isothermal amplification combined with lateral flow dipstick for an easy and rapid detection of Jembrana disease virus
    Kusumawati A.
    Tampubolon I.D.
    Hendarta N.Y.
    Salasia S.I.O.
    Wanahari T.A.
    Mappakaya B.A.
    Hartati S.
    VirusDisease, 2015, 26 (3) : 189 - 195
  • [38] Rapid and sensitive detection of Laem-Singh virus by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick
    Arunrut, Narong
    Seetang-Nun, Yortyot
    Phromjai, Jurairat
    Panphut, Wattana
    Kiatpathomchai, Wansika
    JOURNAL OF VIROLOGICAL METHODS, 2011, 177 (01) : 71 - 74
  • [39] Colorimetric detection of viable antibiotic resistant Enterococcus mediated by cordless operation of reverse transcription loop-mediated isothermal amplification
    Trinh, Thi Ngoc Diep
    Lee, Nae Yoon
    JOURNAL OF BIOTECHNOLOGY, 2022, 357 : 92 - 99
  • [40] Development of one-step reverse transcription loop-mediated isothermal amplification for norovirus detection in oysters
    Jeon, Su Been
    Seo, Dong Joo
    Oh, Hyejin
    Kingsley, David H.
    Choi, Changsun
    FOOD CONTROL, 2017, 73 : 1002 - 1009