Molecular diagnostics for clinical respiratory virus on a total integrated centrifugal microsystem using reverse transcription-loop-mediated isothermal amplification

被引:7
|
作者
Phan V.M. [1 ]
Kang S.W. [2 ]
Kim Y.H. [2 ]
Lee M.Y. [3 ]
Nguyen H.V. [1 ]
Jeon Y.L. [4 ]
Lee W.I. [3 ]
Seo T.S. [1 ]
机构
[1] Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin
[2] Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kyung Hee University Hospital at Gangdong, College of Medicine, Kyung Hee University, Seoul
[3] Department of Laboratory Medicine, Kyung Hee University College of Medicine, Kyung Hee University Hospital at Gangdong, Seoul
[4] Department of Laboratory Medicine, Green Cross Laboratories, Yongin-si
基金
新加坡国家研究基金会;
关键词
Centrifugal microfluidics; COVID-19; Loop-mediated isothermal amplification; Point-of-care; Respiratory virus;
D O I
10.1016/j.snb.2023.133962
中图分类号
学科分类号
摘要
Respiratory viruses are highly contagious agents that can cause endemic and epidemic infections in humans. Early detection of these viruses is crucial in preventing economic damage and reducing mortality rates. In this study, we present a total integrated genetic analyzer to perform a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay for the simultaneous detection of 7 respiratory viruses (Influenza A H1N1 and H3N2, Influenza B, Respiratory syncytial virus A and B, Adenovirus, and COVID-19). The primer sets for the RT-LAMP assay were designed and evaluated in comparison with the RT-PCR assay using clinical samples, confirming high specificity and efficiency. The entire process of viral RNA extraction, reagent mixing, gene amplification, and detection was completed on the device in 1 hr 20 min. The constructed portable diagnostic instrument is equipped with a rotary motor, two sets of peltier heaters, a fluorescence detector, and a touch screen for inputting experimental parameters and displaying result. The proposed point-of-care (POC) diagnostic platform correctly analyzed a total of 21 clinical samples (3 for each of the 7 viruses). The limit-of-detection (LOD) for Influenza A subtype H3N2 was 101 pfu/mL, which demonstrates the high performance of our proposed centrifugal microsystem for on-site molecular diagnostics in medical centers. © 2023 Elsevier B.V.
引用
收藏
相关论文
共 50 条
  • [21] An integrated microfluidic platform featuring real-time reverse transcription loop-mediated isothermal amplification for detection of COVID-19
    Jhou, You-Ru
    Wang, Chih-Hung
    Tsai, Huey-Pin
    Shan, Yan-Shen
    Lee, Gwo-Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 358
  • [22] Rapid detection of European orthobunyaviruses by reverse transcription loop-mediated isothermal amplification assays
    Camp, Jeremy V.
    Nowotny, Norbert
    JOURNAL OF VIROLOGICAL METHODS, 2016, 236 : 252 - 257
  • [23] One Step Reverse Transcription Loop-mediated Isothermal Amplification for Influenza A Rapid Detection
    Tun, H. M.
    Wongphatcharachai, M.
    Wisedchanwet, T.
    Kitikoon, P.
    Amonsin, A.
    THAI JOURNAL OF VETERINARY MEDICINE, 2009, 39 (04): : 374 - 375
  • [24] Rapid detection of sacbrood virus (SBV) by one-step reverse transcription loop-mediated isothermal amplification assay
    Yang Jin-Long
    Yang Rui
    Shen Ke-Fei
    Peng Xiang-Wei
    Xiong Tao
    Liu Zuo-Hua
    Virology Journal, 9
  • [25] Detection of shrimp infectious myonecrosis virus by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick
    Puthawibool, Teeranart
    Senapin, Saengchan
    Kiatpathomchai, Wansika
    Flegel, Timothy W.
    JOURNAL OF VIROLOGICAL METHODS, 2009, 156 (1-2) : 27 - 31
  • [26] One-step reverse transcription loop-mediated isothermal amplification for the detection of Capsicum chlorosis virus in Phalaenopsis orchids
    Cheng-Ping Kuan
    Yu-Fei Lin
    Yu-Chun Lin
    Chin-Chih Chen
    Journal of General Plant Pathology, 2016, 82 : 307 - 313
  • [27] Colorimetric detection of hepatitis E virus based on reverse transcription loop mediated isothermal amplification (RT-LAMP) assay
    Chen Qiuhua
    Yuan Lu
    Wan Jun
    Chen Yanlin
    Du Chaoyang
    JOURNAL OF VIROLOGICAL METHODS, 2014, 197 : 29 - 33
  • [28] One-step reverse transcription loop-mediated isothermal amplification for the detection of Capsicum chlorosis virus in Phalaenopsis orchids
    Kuan, Cheng-Ping
    Lin, Yu-Fei
    Lin, Yu-Chun
    Chen, Chin-Chih
    JOURNAL OF GENERAL PLANT PATHOLOGY, 2016, 82 (06) : 307 - 313
  • [29] Rapid detection of sacbrood virus (SBV) by one-step reverse transcription loop-mediated isothermal amplification assay
    Yang Jin-Long
    Yang Rui
    Shen Ke-Fei
    Peng Xiang-Wei
    Xiong Tao
    Liu Zuo-Hua
    VIROLOGY JOURNAL, 2012, 9
  • [30] Rapid Visual Detection Method for Barley Yellow Mosaic Virus Using Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP)
    Chen, Zhiwei
    Mao, Shuihua
    Zhang, Wan
    Fan, Xiaorui
    Wu, Wenjing
    Liu, Chenghong
    Zhao, Kai
    Lu, Ruiju
    PLANT DISEASE, 2021, 105 (09) : 2658 - 2663