Identification of lightning strike disturbance and faults for transmission line based on transient waveform characteristics

被引:0
|
作者
Lü Z. [1 ]
Wang Z. [1 ]
机构
[1] State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing
基金
中国国家自然科学基金;
关键词
lightning strike; sine fitting; transient component; transmission line; waveform characteristic;
D O I
10.19783/j.cnki.pspc.190580
中图分类号
学科分类号
摘要
With the large number of power electronic devices applied to the power grid, the advantages of transient protection are more obvious. For the problem that it is susceptible to lightning strikes, the additional component of transient current in each phase are analyzed under short-circuit fault, lightning strike disturbance and lightning strike causing fault. The essential difference between fault and disturbance is whether the trend of the transient waveform has the characteristic of power frequency sine wave. Accordingly, the method of using the average value sliding denoising can eliminate the high frequency effects such as lightning current, and obtain the main waveform. It is proposed to fit the main wave with a 50 Hz sinusoidal function. Based on the determination coefficient criterion of fitting, the faults and lightning strike disturbance of each phase line can be distinguished. The PSCAD/EMTDC electromagnetic transient simulation results verify that the proposed identification scheme can correctly identify lightning strikes and faults under various scenarios. It is suitable for various transmission lines without being affected by the inception angle of the fault and the transition resistance. © 2020 Power System Protection and Control Press. All rights reserved.
引用
收藏
页码:18 / 26
页数:8
相关论文
共 23 条
  • [1] FADHEL A A, TARLOCHAN S S, RAJIV K V., Performance comparison of distance protection schemes for shunt-FACTS compensated transmission lines, IEEE Transactions on Power Delivery, 22, 4, pp. 2116-2125, (2007)
  • [2] LI Zhongqing, CAO Hong, ZHANG He, Et al., Analysis of the impact of 500 kV UPFC on impedance directional protection based on variation, Power System Protection and Control, 46, 22, pp. 55-63, (2018)
  • [3] ZHOU X Y, WANG H F, AGGARWAL R K, Et al., Performance evaluation of a distance relay as applied to a transmission system with UPFC, IEEE Transactions on Power Delivery, 21, 3, pp. 1137-1147, (2006)
  • [4] DUAN Jiandong, ZHANG Baohui, LI Peng, Et al., Study of transient approach of discriminating lightning disturbance in ultra-high-speed protection, Proceedings of the CSEE, 27, 7, pp. 45-51, (2007)
  • [5] LIU Qing, WANG Zengping, ZHENG Zhenhua, Et al., Non-unit transient protection based on signal complexity for series compensated transmission lines, Proceedings of the CSEE, 30, 13, pp. 81-88, (2010)
  • [6] DUAN Jiandong, REN Jinfeng, ZHANG Baohui, Et al., Study of transient approach of discriminating lightning disturbance in ultra-high-speed protection, Proceedings of the CSEE, 26, 23, pp. 7-13, (2006)
  • [7] ZHAO Jun, LU Yanping, WANG Hanguang, New scheme to identify lightning disturbance for the UHV transmission lines based on multi-scale morphology decomposition, High Voltage Engineering, 35, 5, pp. 994-998, (2009)
  • [8] WANG Gang, LI Haifeng, ZHAO Jiancang, Et al., Identification of transients on transmission lines caused by direct lightning strokes based on multiresolution signal decomposition, Proceedings of the CSEE, 24, 4, pp. 143-148, (2004)
  • [9] GAO Yanfeng, HUANG Xiaoyin, YAN Hongyan, Et al., Study on synthetic identification of lightning fault of power transmission lines, Guangdong Electric Power, 29, 3, pp. 93-98, (2016)
  • [10] LUO Richeng, LI Wen, LU Yi, Et al., Identification method of shielding failure and back striking over-voltage of 1 000 kV transmission line based on Hilbert-Huang transform, Transactions of China Electrotechnical Society, 30, 3, pp. 232-239, (2015)