Validation of Monte Carlo Model for Dose Evaluation outside the Treatment Field for Siemens 6MV Beam

被引:0
|
作者
Sinousy D.M. [1 ]
Attalla E.M. [2 ]
Fathy I.H. [3 ,4 ,5 ]
Elhussiny F.A. [4 ]
Elmekawy A.F. [4 ]
机构
[1] National Cancer Institute, Cairo University
[2] Faculty of Science, Physics Department, Cairo University
来源
Sinousy, Dina Mohamed | 1600年 / Mashhad University of Medical Sciences卷 / 17期
关键词
Linear Accelerator; Monte Carlo Method; Out-of-Field Dose; Radiotherapy;
D O I
10.22038/ijmp.2019.42881.1646
中图分类号
学科分类号
摘要
Introduction: There has been a concern about the unintended doses to critical structures outside the treatment field due to the increased risk of radiation-induced second cancer following radiotherapy — treatments. Today, Monte Carlo (MC) simulation is considered the most accurate method for dose calculations in different domains of medical physics. Material and Methods: The Geant4 Application for Tomographic Emission (GATE) code was used to create an MC model of 6MV Siemens Primus linac. Measurements were taken in a water phantom using an ion — chamber to validate the MC model. Dose profiles outside the treatment field at 1.5 (dmax), 5.0 andl0.0 cm depths for field sizes from 5&multipul; 5 to 20&multipul; 20 cm2 were measured in the present study. Out-of-field percentage depth dose (PDD) curves at 0.0, 5.0, and 7.5 cm off axis for field size 10&multipul; 10 cm2 were investigated for both measurements and simulation. However out-of-field PDDs from 10 to 15 cm off axis for field size 10&multipul; 10 cm2 were studied only by simulation. Results: The comparisons showed agreement between the measured and simulated doses for the out-of-field profiles along the in-plane direction for all considered field sizes and depths, as well as for the PDDs at 0.0 and 5.0 cm off axis, but with less agreement at 7.5 cm off axis. All the simulated out-of-field PDDs at distances > 10 cm off axis had similar trend shapes. Conclusion: The developed MC model is considered a good representation of 6 MV Siemens Primus linac for the out-of-field dose calculation in lieu of measurements. The authors would like to thank "Mit Ghamr Oncology Center" for its generous cooperation with this study. The authors would also like to extend their gratitude to Eng. Mohamed Osama, a biomedical engineer and president of On-medical Company for his great efforts in this project. © 2020. All Rights Reserved.
引用
收藏
页码:410 / 420
页数:10
相关论文
共 50 条
  • [1] Validation of BEAMnrc Monte Carlo model for a 12 MV photon beam
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Saeed, M.
    Jamal, Al Zain
    Mohamed, Landour
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2018, 30 (04) : 537 - 543
  • [2] Out-of-field beam characteristics of a 6 MV photon beam: Results of a Monte Carlo study
    Atarod, M.
    Shokrani, P.
    Azarnoosh, A.
    APPLIED RADIATION AND ISOTOPES, 2013, 72 : 182 - 194
  • [3] Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom
    Farajollahi A.
    Mesbahi A.
    Radiation Medicine, 2006, 24 (4): : 269 - 276
  • [4] A Monte Carlo model of an agility head for a 6 MV Elekta photon beam
    Al-Saleh, Wafa M.
    Almatani, Turki
    RADIATION PHYSICS AND CHEMISTRY, 2024, 216
  • [5] Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6 MV photon beam
    Tugrul, Taylan
    Erogul, Osman
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (04) : 331 - 337
  • [6] Monte Carlo Simulation of Surface Dose and Dose Rate in 6MV-FFF Beams
    Assalmi, Mustapha
    Diaf, El Yamani
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S36 - S51
  • [7] Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18 MV photon beam: Determination of initial electron beam parameters
    Najafzadeh, Milad
    Hoseini-Ghafarokhi, Mojtaba
    Bolagh, Rezgar Shahi Mayn
    Haghparast, Mohammad
    Zarifi, Shiva
    Nickfarjam, Abolfazl
    Farhood, Bagher
    Chow, James C. L.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (06) : 1047 - 1070
  • [8] Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening filter-free 7 MV beam line
    Sadrollahi, Alemeh
    Nuesken, Frank
    Licht, Norbert
    Ruebe, Christian
    Dzierma, Yvonne
    PLOS ONE, 2019, 14 (01):
  • [9] A Simple Source Model for 6 MV Flattening Filter Free Photon Beams Monte Carlo Dose Calculations
    Ezzati, Ahad Ollah
    Studenski, Matthew T.
    Jamshidi, Negin
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2021, 18 (07) : 791 - 798
  • [10] Monte carlo model and output factors of elekta Infinity™ 6 and 10 MV photon beam
    Yani, Sitti
    Budiansah, Indra
    Rhani, Mohamad Fahdillah
    Haryanto, Freddy
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (04) : 470 - 478