In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS

被引:0
|
作者
Tian, Jing [1 ]
Bao, Zhian [1 ]
Chen, Kaiyun [1 ]
Zong, Chunlei [1 ]
Zhang, Yan [1 ]
Peng, Deyi [1 ]
Yuan, Honglin [1 ]
机构
[1] Department of Geology, State Key Laboratory of Continental Dynamics, Northwest University, Xi'an,710069, China
来源
关键词
Isotopes;
D O I
暂无
中图分类号
学科分类号
摘要
This study developed a new method for in situ measurement of stable Mo isotope ratio using femtosecond laser ablation connected to a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS). We assessed how laser fluence, laser repetition rate, and signal intensity impact Mo isotope mass fractionation, using synthetic molybdenite Mo-H8 as the reference material. Findings reveal that the laser repetition rate has negligible impact on Mo isotope fractionation, while signal intensity and laser fluence slightly influence the precision of δ98Mo. Significant signal intensity disparities between samples and reference materials can markedly affect the results of Mo isotopes. We analyzed natural molybdenite samples from various deposits in China with this new method, with the optimal laser parameters including a repetition rate of 10 Hz, a spot size of 20 μm, and a fluence of 1 J cm−2. The δ98MoNIST SRM 3134 values for nine natural samples (GD-1, GD-2, YN-1, YN-2, YN-3, SX-1, SX-2, SX-3, and GX-1) align with those obtained by solution nebulization MC-ICP-MS within analytical uncertainty, demonstrating the accuracy of this new in situ Mo isotope analytical method. This new technique offers a reliable alternative to solution nebulization MC-ICP-MS in bulk analysis, enabling precise detection of Mo isotope ratio variations at a finer scale, which provides valuable insights into mineralization processes. © 2024 The Royal Society of Chemistry.
引用
收藏
页码:2021 / 2029
相关论文
共 50 条
  • [11] ANALYSIS OF TITANIUM ISOTOPE RATIOS IN REFRACTORY INCLUSIONS BY LA-MC-ICP-MS
    Williams, C. D.
    Wadhwa, M.
    Janney, P. E.
    Hines, R. R.
    Bullock, E. S.
    MacPherson, G. J.
    METEORITICS & PLANETARY SCIENCE, 2011, 46 : A250 - A250
  • [12] High-Precision Fe and Mg Isotope Ratios of Silicate Reference Glasses Determined In Situ by Femtosecond LA-MC-ICP-MS and by Solution Nebulisation MC-ICP-MS
    Oeser, Martin
    Weyer, Stefan
    Horn, Ingo
    Schuth, Stephan
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (03) : 311 - 328
  • [13] Alternative data reduction for precise and accurate isotope ratio determination via LA-MC-ICP-MS
    Fietzke, J.
    Liebetrau, V.
    Guenther, D.
    Frische, A.
    Zumholz, K.
    Hansteen, T. H.
    Eisenhauer, A.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A267 - A267
  • [14] In situ Nd isotope measurement of bastnaesite via LA-MC-ICP-MS
    Yang, Y. -H.
    Wu, F. -Y.
    Fan, H. -R.
    Xie, L. -W.
    Zhang, Y. -B.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A1481 - A1481
  • [15] In situ boron isotope measurements of natural geological materials by LA-MC-ICP-MS
    Hou KeJun
    Li YanHe
    Xiao YingKai
    Liu Feng
    Tian YouRong
    CHINESE SCIENCE BULLETIN, 2010, 55 (29): : 3305 - 3311
  • [16] In situ Hf isotope analysis of cassiterite by LA-MC-ICP-MS: protocol and applications
    Yang, Ming
    Yang, Yue-Heng
    Romer, Rolf L.
    Wu, Shi-Tou
    Wu, Tao
    Wang, Hao
    Journal of Analytical Atomic Spectrometry, 2022, 38 (02): : 437 - 448
  • [17] In-situ analysis of Pb isotope ratios by LA-MC-ICP-MS:: Applications to ore genesis and igneous petrogenesis
    Kent, AJR
    Dilles, JH
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A376 - A376
  • [18] In situ Hf isotope analysis of cassiterite by LA-MC-ICP-MS: protocol and applications
    Yang, Ming
    Yang, Yue-Heng
    Romer, Rolf L.
    Wu, Shi-Tou
    Wu, Tao
    Wang, Hao
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (02) : 437 - 448
  • [19] In situ boron isotope measurements of natural geological materials by LA-MC-ICP-MS
    HOU KeJun1
    2 Institute of Salt Lakes
    3 Thermo Fisher Scientific(Shanghai) Co.
    Science Bulletin, 2010, (29) : 3305 - 3311
  • [20] A comparison of zircon Hf isotope analyses by MC-ICP-MS and LA-MC-ICP-MS
    Zhang, L
    Han, BF
    Gu, LB
    Zhang, WH
    Xie, LW
    Yang, YH
    ACTA PETROLOGICA SINICA, 2006, 22 (02) : 510 - 512