In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS

被引:0
|
作者
Tian, Jing [1 ]
Bao, Zhian [1 ]
Chen, Kaiyun [1 ]
Zong, Chunlei [1 ]
Zhang, Yan [1 ]
Peng, Deyi [1 ]
Yuan, Honglin [1 ]
机构
[1] Department of Geology, State Key Laboratory of Continental Dynamics, Northwest University, Xi'an,710069, China
来源
关键词
Isotopes;
D O I
暂无
中图分类号
学科分类号
摘要
This study developed a new method for in situ measurement of stable Mo isotope ratio using femtosecond laser ablation connected to a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS). We assessed how laser fluence, laser repetition rate, and signal intensity impact Mo isotope mass fractionation, using synthetic molybdenite Mo-H8 as the reference material. Findings reveal that the laser repetition rate has negligible impact on Mo isotope fractionation, while signal intensity and laser fluence slightly influence the precision of δ98Mo. Significant signal intensity disparities between samples and reference materials can markedly affect the results of Mo isotopes. We analyzed natural molybdenite samples from various deposits in China with this new method, with the optimal laser parameters including a repetition rate of 10 Hz, a spot size of 20 μm, and a fluence of 1 J cm−2. The δ98MoNIST SRM 3134 values for nine natural samples (GD-1, GD-2, YN-1, YN-2, YN-3, SX-1, SX-2, SX-3, and GX-1) align with those obtained by solution nebulization MC-ICP-MS within analytical uncertainty, demonstrating the accuracy of this new in situ Mo isotope analytical method. This new technique offers a reliable alternative to solution nebulization MC-ICP-MS in bulk analysis, enabling precise detection of Mo isotope ratio variations at a finer scale, which provides valuable insights into mineralization processes. © 2024 The Royal Society of Chemistry.
引用
收藏
页码:2021 / 2029
相关论文
共 50 条
  • [1] In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Zhang, Yan
    Peng, Deyi
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (08) : 2021 - 2029
  • [2] In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS
    Kaufmann, A. B.
    Lazarov, M.
    Kiefer, S.
    Majzlan, J.
    Weyer, S.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (07) : 1554 - 1567
  • [3] In situ-Fe isotope determination using femtosecond LA-MC-ICP-MS
    Steinhoefel, G
    Horn, I
    Schoenberg, R
    Von Blanckenburg, F
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A374 - A374
  • [4] In situ determination of Cu isotope ratios in copper-rich materials by NIR femtosecond LA-MC-ICP-MS
    Ikehata, Kei
    Notsu, Kenji
    Hirata, Takafumi
    Journal of Analytical Atomic Spectrometry, 2008, 23 (07): : 1003 - 1008
  • [5] In situ determination of Cu isotope ratios in copper-rich materials by NIR femtosecond LA-MC-ICP-MS
    Ikehata, Kei
    Notsu, Kenji
    Hirata, Takafumi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (07) : 1003 - 1008
  • [6] Accurate determination of Ba isotope ratios in barite samples by LA-MC-ICP-MS
    Zhang, Shenghua
    Zhang, Wen
    Yu, Huimin
    Huang, Fang
    Wang, Chao
    Luo, Tao
    Liu, Yongsheng
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2637 - 2646
  • [7] In situ lithium isotope analysis by LA-MC-ICP-MS
    le Roux, P. J.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A744 - A744
  • [8] In situ carbon stable isotope measurement for graphite using LA-MC-ICP-MS
    Zhang, Jihao
    Li, Chao
    Li, Xinwei
    Wang, Wei
    Yu, Pengyue
    Zhou, Limin
    Qu, Wenjun
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (03) : 800 - 807
  • [9] A simplified procedure for the determination of stable chlorine isotope ratios (δ37Cl) using LA-MC-ICP-MS
    Fietzke, Jan
    Frische, Matthias
    Hansteen, Thor H.
    Eisenhauer, Anton
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (05) : 769 - 772
  • [10] In situ carbon isotope analysis of diamonds using LA-MC-ICP-MS inspired by the distribution of ions and isotope ratios in ICP
    Huo, Yi-Ming
    Zhu, Zhi-Yong
    Fan, Chang-Fu
    She, Yu-Wei
    Hao, Jia-Long
    Zhu, Xiang-Kun
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (03)