Resistance characteristics of unidirectional carbon fiber/epoxy prepreg subjected to simulated lightning currents

被引:0
|
作者
Chen J. [1 ]
Fu Z. [1 ]
机构
[1] Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai
关键词
Damage; Direct current (DC) resistance; Epoxy prepreg; Graphitization; Simulated lightning current; Unidirectional carbon fiber;
D O I
10.13801/j.cnki.fhclxb.20190412.001
中图分类号
学科分类号
摘要
In order to investigate the resistance characteristics of unidirectional carbon fiber/epoxy prepreg subjected to lightning currents, low simulated lightning currents of 10/350 μs waveform were applied on the unidirectional carbon fiber/epoxy prepreg. The direct current (DC) resistance data of the unidirectional carbon fiber/epoxy prepreg before and after the tests were measured adopting the four-probe method. The SEM and Raman spectrum were used to characterize the morphology and phase structure of carbon fiber/epoxy prepreg before and after the test. The causes of the DC resistance change were analyzed. The results show that the DC resistance of the carbon fiber/epoxy prepreg does not change monotonously with the increase of lightning current, but tends to decrease first and then increase. This trend is the combined effects of graphitization, epoxy insulation deterioration, fiber fracture and tunnel effect. © 2020, Editorial Office of Acta Materiae Compositae Sinica. All right reserved.
引用
收藏
页码:82 / 88
页数:6
相关论文
共 24 条
  • [1] Leon M., Kim B., Helga P., Et al., Materials for wind turbine blades: An overview, Materials, 10, 11, pp. 1285-1308, (2017)
  • [2] Du S.Y., Advanced composite materials and aerospace engineering, Acta Materiae Compositae Sinica, 24, 1, pp. 1-12, (2007)
  • [3] Yin J.J., Li S.L., Yao X.L., Et al., Ablation damage characteristic analysis of composite laminate with fastener subjected to lightning strike, Acta Materiae Compositae Sinica, 34, 1, pp. 104-111, (2017)
  • [4] Wolfrum J., Schuster T.J., Korwien T., Effects of heavy lightning strikes on pristine and repaired carbon composite structures, Journal of Composite Materials, 51, 25, pp. 3491-3504, (2017)
  • [5] Chemartin L., Lalande P., Peyrou B., Et al., Direct effects of lightning on aircraft structure: Analysis of the thermal, electrical and mechanical constraints, Aerospace Lab, 5, pp. 1-15, (2012)
  • [6] Liu Z.Q., Yue Z.F., Wang F.S., Et al., Damage zoning characteristics of composite laminates with different protections subjected to lightning strike, Acta Materiae Compositae Sinica, 32, 1, pp. 284-294, (2015)
  • [7] Lee J., Lacy T.E., Pittman C.U., Et al., Thermal response of carbon fiber epoxy laminates with metallic and nonmetallic protection layers to simulated lightning currents, Polymer Composites, 39, pp. 2149-2166, (2018)
  • [8] Swait T.J., Jones F.R., Hayes S.A., A practical structural health monitoring system for carbon fibre reinforced composite based on electrical resistance, Composites Science and Technology, 72, 13, pp. 1515-1523, (2012)
  • [9] Roh H.D., Lee H., Park Y.B., Structural health monitoring of carbon-material-reinforced polymers using electrical resistance measurement, International Journal of Precision Engineering and Manufacturing-Green Technology, 3, 3, pp. 311-321, (2016)
  • [10] Li X., Wu X., Yang B., A study on the relationship between resistance and temperature of carbon fiber yarn and its textile structure, Journal of Zhejiang Sci-Tech University, 28, 6, pp. 871-874, (2011)