STUDY ON FIRE-RESISTANCE PERFORMANCE OF LIGHTWEIGHT CEMENT MORTAR EXTERNAL WALL BY DIFFERENT TYPES OF CEMENTS

被引:0
作者
Uemura M. [1 ]
Harada S. [1 ]
Watanabe T. [2 ]
Inoue T. [3 ]
机构
[1] Fujikawakenzaikogyo Co., Ltd.
[2] Graduate School of Human Life Science, Osaka Metropolitan Univ
关键词
Cement; Fire-resistance; Heat insulation; Lightweight cement mortar external wall; Non-Damaging;
D O I
10.3130/aijt.30.802
中图分类号
学科分类号
摘要
In this study, the effects of 10 types of cement used for lightweight cement mortar on the fire-resistance performance of the exterior wall of lightweight cement mortar were evaluated. As a result of the heating test, ordinary Portland cement showed the highest temperature at the back surface of lightweight cement mortar, and alumina cement showed the lowest temperature. As for non-damage, there was no explosion or falling off, and no significant difference in damage was observed. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:802 / 807
页数:5
相关论文
共 10 条
  • [1] Insulating and fire-resistance performance of calcium aluminate cement based lightweight mortars
    Koksal, Fuat
    Cosar, Kubra
    Dener, Murat
    Benli, Ahmet
    Gencel, Osman
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 362
  • [2] Improved Fire Resistance by Using Different Types of Cements
    Lubloy, Eva
    Kopecsko, Katalin
    Balazs, Gyorgy L.
    PROCEEDINGS OF ITALIAN CONCRETE DAYS 2016, 2018, 10 : 219 - 228
  • [3] Evaluation of fire-resistance performance for modular structures based on fireproof coating types
    Lee, Jun-Seop
    Woo, Jong-Hun
    Shin, Kyung-Jae
    Lee, Hee-du
    STRUCTURES, 2024, 67
  • [4] Comparative experimental study of fire-resistance ratings of timber assemblies with different fire protection measures
    Xu, Qingfeng
    Wang, Yong
    Chen, Lingzhu
    Gao, Rundong
    Li, Xiangmin
    ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (03) : 500 - 512
  • [5] Study on prediction method for insulation of triple-layer wall using "Inclusive thermal conductivity" in fire-resistance test
    Yoshitani K.
    Shimizu T.
    Yoshida M.
    Journal of Environmental Engineering (Japan), 2020, 85 (778): : 903 - 911
  • [6] Evaluation of fire performance of external wall cladding systems with rigid polyurethane insulation in different applications
    Zeng, Xubin
    Zhao, Chenggang
    Lu, Guojian
    Liu, Junjun
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2014, 17 (05): : 843 - 848
  • [7] Experimental evaluation of fire resistance performance of cement mortar with PCM/Mg(OH)2-based composite fine aggregate
    Yoo, Dong Ho
    Jeon, In Kyu
    Kim, Hong Gi
    Lee, Jun Suk
    Ryou, Jae-Suk
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 287 (287)
  • [8] Study on fire resistance of high performance concrete nonplanar beam-wall joints
    Shen, Yongjiang
    He, Linpei
    Dai, Mengting
    Wang, Qilin
    Xiang, Zhengliang
    STRUCTURES, 2024, 66
  • [9] The Application of Silica-Based Aerogel Board on the Fire Resistance and Thermal Insulation Performance Enhancement of Existing External Wall System Retrofit
    Liu, Kuang-Sheng
    Zheng, Xiao-Feng
    Hsieh, Chia-Hsing
    Lee, Shin-Ku
    ENERGIES, 2021, 14 (15)
  • [10] Experimental study to assess the impact of different connection types on the fire resistance of composite concrete-topped CLT slabs
    Chen, Lingzhu
    Wang, Mingqian
    Xu, Qingfeng
    Harries, Kent A.
    Chen, Xi
    Xiao, Shun
    FIRE SAFETY JOURNAL, 2024, 150