Development of size-specific institutional diagnostic reference levels for computed tomography protocols in neck imaging

被引:3
作者
Steuwe A. [1 ]
Thomas C. [1 ]
Kraus B. [1 ]
Bethge O.T. [1 ]
Aissa J. [1 ]
Klosterkemper Y. [1 ]
Antoch G. [1 ]
Boos J. [1 ]
机构
[1] University Düsseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Düsseldorf
关键词
computed tomography; diagnostic reference levels; neck CT imaging;
D O I
10.1088/1361-6498/ab4d00
中图分类号
学科分类号
摘要
Purpose: To develop size-specific institutional diagnostic reference levels (DRLs) for computed tomography (CT) protocols used in neck CT imaging (cervical spine CT, cervical CT angiography (CTA) and cervical staging CT) and to compare institutional to national DRLs. Materials and methods: Cervical CT examinations (spine, n = 609; CTA, n = 505 and staging CT, n = 184) performed between 01/2016 and 06/2017 were included in this retrospective study. For each region and examination, the volumetric CT dose index (CTDIvol) and dose-length product (DLP) were determined and binned into size bins according to patient water-equivalent diameter (dw). Linear regression analysis was performed to calculate size-specific institutional DRLs for CTDIvol and DLP, applying the 75th percentile as the upper limit for institutional DRLs. The mean institutional CTDIvol and DLP were compared to national DRLs (CTDIvol 20 mGy for cervical spine CT (DLP 300 mGycm) and cervical CTA (DLP 600 mGycm), and CTDIvol 15 mGy for cervical staging CT (DLP 330 mGycm)). Results: The mean CTDIvol and DLP (standard deviation) were 15.2 4.1 mGy and 181.5 88.3 mGycm for cervical spine CT; 8.1 4.3 mGy and 280.2 164.3 mGycm for cervical CTA; 8.6 1.9 mGy and 162.8 85.0 mGycm for cervical staging CT. For all CT protocols, there was a linear increase in CTDIvol and DLP with increasing dw. For the CTDIvol, size-specific institutional DRLs increased with dw from 14 to 29 mGy for cervical spine CT, from 5 to 17 mGy for cervical CTA and from 8 to 13 mGy for cervical staging CT. For the DLP, size-specific institutional DRLs increased with dw from 130 to 510 mGycm for cervical spine CT, from 140 to 640 mGycm for cervical CTA and from 140 to 320 mGycm for cervical staging CT. Institutional DRLs were lower than national DRLs by 81% and 67% for cervical spine CT (dw = 17.8 cm), 43% and 51% for cervical CTA (dw = 19.5 cm) and 59% and 53% for cervical staging CT (dw = 18.8 cm) for CTDIvol and DLP, respectively. Conclusion: Size-specific institutional DRLs were generated for neck CT examinations. The mean institutional CTDIvol and DLP values were well below national DRLs. © 2019 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved..
引用
收藏
页码:68 / 82
页数:14
相关论文
共 31 条
  • [21] Vachha B., Brodoefel H., Wilcox C., Hackney D.B., Moonis G., Radiation dose reduction in soft tissue neck CT using adaptivestatistical iterative reconstruction (ASIR), Eur. J. Radiol., 82, pp. 2222-2226, (2013)
  • [22] Den Harder A.M., Willemink M.J., De Ruiter Q.M.B., Schilham A.M.R., Krestin G.P., Leiner T., De Jong P.A., Budde R.P.J., Achievable dose reduction using iterative reconstruction for chest computed tomography: A systematic review, Eur. J. Radiol., 84, pp. 2307-2313, (2015)
  • [23] Kahn J., Grupp U., Kaul D., Ning G.B., Lindner T., Streitparth F., Computed tomography in trauma patients using iterative reconstruction: Reducing radiation exposure without loss of image quality, Acta Radiol., 57, pp. 362-369, (2016)
  • [24] Parakh A., Kortesniemi M., Schindera S.T., CT radiation dose management: A comprehensive optimization process for improving patient safety, Radiology, 280, pp. 663-673, (2016)
  • [25] Christner J.A., Braun N.N., Jacobsen M.C., Carter R.E., Kofler J.M., McCollough C.H., Size-specific dose estimates for adult patients at CT of the torso, Radiology, 265, pp. 841-847, (2012)
  • [26] Boone J.M., Strauss K.J., Cody D.D., McCollough C.H., McNitt-Gray M.F., Toth T.L., Goske M.J., Frush D.P., (2011)
  • [27] Boone J., Et al., (2019)
  • [28] Papadakis A.E., Damilakis J., Automatic tube current modulation and tube voltage selection in pediatric computed tomography, Invest. Radiol., 54, pp. 265-272, (2019)
  • [29] Sookpeng S., Martin C.J., Gentle D.J., Investigation of the influence of image reconstruction filter and scan parameters on operation of automatic tube current modulation systems for different CT scanners, Radiat. Prot. Dosimetry, 163, pp. 521-530, (2015)
  • [30] Merzan D., Nowik P., Poludniowski G., Bujila R., Evaluating the impact of scan settings on automatic tube current modulation in CT using a novel phantom, Br. J. Radiol., 90, (2017)