Establishment of Diagnostic Reference Levels and Evaluation of Radiation Dose in Double Phase Abdominopelvic Computed Tomography

被引:0
|
作者
Keshtkar M. [1 ]
机构
[1] Medical Physics and Radiology Department, Faculty of Medicine, Infectious Diseases Research Center, Gonabad University of Medical Sciences, Gonabad
关键词
Abdomen; Computed Tomography; Effective Dose; Justification; Pelvis;
D O I
10.22038/IJMP.2022.64450.2105
中图分类号
学科分类号
摘要
Introduction: The purpose of this study was to establish of diagnostic reference level (DRL) and to compare radiation dose between single phase and unjustified double phase abdominopelvic CT imaging. Material and Methods: A total of 163 patients, 85 patients with single phase and 78 patients with unjustified double phase abdominopelvic CT scans, were included in this retrospective study. Volumetric CT dose index (CTDIvol) and dose length product (DLP) were obtained from the CT console. The third quartile of CTDIvol and DLP were determined for diagnostic reference level (DRL). Effective dose (E) and organ dose were obtained using CT-Expo software (version 2.2). Single phase and double phase scans were compared in terms of CTDIvol, DLP, size-specific dose estimate (SSDE), E and organ doses. Results: The institutional DRLs using CTDIvol and DLP for abdominopelvic CT were 9.8 mGy and 571 mGy.cm, respectively. The mean value of E was 5.4 ± 1.8 and 10.3 ± 3.4 for single phase and double phase imaging, respectively, resulting in 4.9 mSv excess dose per patient. Mean value of the DLP was 396.9 ± 142.7 and 759.0 ± 250.7 for single phase and double phase imaging, respectively. E was significantly higher in female compared to male (p < 0.05). Bladder has a highest lifetime attributed risk of cancer incidence among other organs. Also, the cancer risk incidence was higher for female than male. Conclusion: The awareness of physicians about the correct indications of abdominopelvic CT should be increased by using associated reliable guidelines. © 2023.
引用
收藏
页码:80 / 86
页数:6
相关论文
共 50 条
  • [1] Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
    Radaideh, Khaldoon
    Al-Radaideh, Ali
    Ramli, Ramzun Maizan
    Saleh, Abdallah
    Alshayeb, Rasha
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 26 - 34
  • [2] A Contribution to the Establishment of Diagnostic Reference Levels in Computed Tomography in Brazil
    Narciso, L. D. L.
    Lima, N. W.
    Dartora, C. M.
    Marques da Silva, A. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 737 - 740
  • [3] Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey
    Amalaraj, T.
    Satharasinghe, Duminda
    Pallewatte, Aruna
    Jeyasugiththan, Jeyasingam
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [4] Establishment of diagnostic reference levels and estimation of effective dose from computed tomography head scans at a tertiary hospital in South Africa
    Nyathi M.
    Iranian Journal of Medical Physics, 2020, 17 (02) : 99 - 106
  • [5] Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
    Saravanakumar, A.
    Vaideki, K.
    Govindarajan, K. N.
    Jayakumar, S.
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (01) : 50 - 55
  • [6] Radiation dose assessment: Establishment of local diagnostic reference levels for selected radiography examinations across three prominent hospitals in Sudan
    Osman, Hamid
    Ahmed, Amna Mohamed
    Musa, Alamin
    Medani, Afaf
    Abouraida, Raga Ahmed
    Alelyani, Magbool
    Alamri, Sultan
    Abdelrahim, Elrashed
    Hassan, W. B.
    Faizo, Nahla L.
    Alotaibi, Sahal
    Khandaker, Mayeen Uddin
    Sulieman, Abdelmoneim
    Omer, Awatif M.
    Awadallah, Babiker A.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 217
  • [7] Radiation safety concerns and diagnostic reference levels for computed tomography scanners in Tamil Nadu
    Livingstone, Roshan S.
    Dinakaran, Paul M.
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (01) : 40 - 45
  • [8] Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia
    Zalokar, Nika
    Marcius, Valerija Zager
    Mekis, Nejc
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 127
  • [9] Australian diagnostic reference levels for multi detector computed tomography
    Anna Hayton
    Anthony Wallace
    Paul Marks
    Keith Edmonds
    David Tingey
    Peter Johnston
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 19 - 26
  • [10] Australian diagnostic reference levels for multi detector computed tomography
    Hayton, Anna
    Wallace, Anthony
    Marks, Paul
    Edmonds, Keith
    Tingey, David
    Johnston, Peter
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (01) : 19 - 26