Plasma column position measurements using magnetic diagnostics in ADITYA-U tokamak

被引:3
|
作者
Aich S. [1 ,5 ]
Kumar R. [5 ]
Macwan T.M. [1 ,5 ]
Kumavat D. [1 ,5 ]
Jha S. [5 ]
Tanna R.L. [2 ,5 ]
Sathyanarayana K. [5 ]
Ghosh J. [1 ,5 ]
Jadeja K.A. [3 ,5 ]
Patel K. [5 ]
Patel S. [4 ]
Ranjan V. [1 ,5 ]
Kalal M. [5 ]
Varia D. [5 ]
Sadharkiya D. [5 ]
Raju D. [1 ,5 ]
Chattopadhyay P.K. [1 ,5 ]
Gupta C.N. [5 ]
Saxena Y.C. [5 ]
机构
[1] Homi Bhabha National Institute Anushaktinagar, Maharashtra, Mumbai
[2] Institute of Science, Nirma University, Gujarat, Ahmedabad
[3] Department of Physics, Saurashtra University, Gujarat, Rajkot
[4] Pandit Deendayal Petroleum University, Raisan, Gujarat, Gandhinagar
[5] Institute for Plasma Research, Gujarat, Gandhinagar
来源
Plasma Research Express | 2021年 / 3卷 / 03期
关键词
Flux loop; Magnetic pick-up probe; Mirnov coil; Sine-Cosine coil;
D O I
10.1088/2516-1067/ac2731
中图分类号
学科分类号
摘要
Due to several forces acting on the plasma column in a tokamak, the plasma column tends to move horizontally and/or vertically leading to many adverse events including termination of plasma. Precise measurement of plasma column position throughout the discharge with good temporal resolution in the real time is hence necessary in order to restrict the column movement using the stabilizing equilibrium magnetic fields. The plasma column position is measured by several magnetic diagnostics such as magnetic pick-up probe, Mirnov coil, Sine-Cosine coil along with flux loops in ADITYA Upgrade tokamak (ADITYA-U). In spite of the simplicity of the measurement principle of these probes as well as of their construction, obtaining the position of the plasma column is not very straightforward. The diversity of all these magnetic diagnostics in terms of their structures, installation location, mounting scenario etc leads to improper position estimations as these probes are being affected differently by the unwanted magnetic pick-ups. These unwanted pickups, especially those arising from vessel eddies, are successfully removed by introducing a scaling method for all the above-mentioned position probes in ADITYA-U based on the in situ calibration of these probes. The correction factors are deduced by estimating the known positions of a central current carrying conductor correctly using the probe measurements during the in situ calibration. These correction factors are used for estimating the plasma column position in the tokamak experiment along with proper nullification of magnetic fields arising from other magnets during tokamak operation. The plasma column position estimation from different magnetic probes are compared with each other and also with those estimated from diagnostics other than the magnetic ones. © 2021 IOP Publishing Ltd
引用
收藏
相关论文
共 50 条
  • [41] Runaway electron mitigation with supersonic molecular beam injection (SMBI) in ADITYA-U tokamak
    Banerjee, Santanu
    Singh, K.
    Raj, H.
    Arambhadiya, B.
    George, Siju
    Jadeja, K. A.
    Singh, Amit K.
    Edappala, Praveenlal
    Bisai, N.
    Ghosh, J.
    Manchanda, R.
    Chowdhuri, M. B.
    Tanna, R. L.
    Raval, Jayesh
    Nagora, U. C.
    Paravastu, Y.
    Raval, D. C.
    Mishra, K.
    Chandra, D.
    Sen, A.
    NUCLEAR FUSION, 2021, 61 (01)
  • [42] Micro-particle injection experiments in ADITYA-U tokamak using an inductively driven pellet injector
    Pahari, Sambaran
    Rahulnath, P. P.
    Savita, Aditya Nandan
    Maurya, Pradeep Kumar
    Jha, Saroj Kumar
    Shiv, Neeraj
    Raghavendra, K.
    Hemani, Harsh
    Nagaraju, Belli
    Mahar, Sukantam
    Rao, Manmadha
    Suryaprasad, I. V. V.
    Malshe, U. D.
    Ghosh, J.
    Doshi, B. R.
    Chattopadhyay, Prabal Kumar
    Tanna, R. L.
    Jadeja, K. A.
    Patel, K. M.
    Kumar, Rohit
    Macwan, Tanmay
    Raj, Harshita
    Aich, S.
    Singh, Kaushlender
    Dolui, Suman
    Kumawat, D.
    Makwana, M. N.
    Shah, K. S.
    Gupta, Shivam
    Balakrishnan, V.
    Gupta, C. N.
    Patnaik, Swadesh Kumar
    Edappala, Praveenlal
    Shah, Minsha
    Kadia, Bhavesh
    Yadava, Nandini
    Shah, Kajal
    Shukla, G.
    Chowdhuri, M. B.
    Manchanda, R.
    Ramaiya, Nilam
    Kumar, Manoj
    Nagora, Umesh
    Varsha, S.
    Pathak, S. K.
    Asudani, Kumudni
    Chaudhuri, Paritosh
    Maya, P. N.
    Goswami, Rajiv
    Sen, A.
    NUCLEAR FUSION, 2024, 64 (05)
  • [43] Improved Horizontal Plasma Position Control Using c-RIO-Based Real Time System in Aditya-U
    Gautam, Pramila
    Raulji, Vismaysinh
    Kumar, Rohit
    Rajpal, Rachana
    Tanna, Rakesh
    Ghosh, Joydeep
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (09) : 3809 - 3813
  • [44] Effect of periodic gas-puffs on drift-tearing modes in ADITYA/ADITYA-U tokamak discharges
    Raj, Harshita
    Macwan, Tanmay
    Singh, Kaushalender
    Dolui, Suman
    Ghosh, Joydeep
    Bisai, Nirmal K.
    Jadeja, K. A.
    Patel, K. M.
    Patel, N. C.
    Tanna, R. L.
    Raju, D.
    Jha, S. K.
    Chattopadhyay, P. K.
    Sen, Abhijit
    Saxena, Y. C.
    Pal, R.
    NUCLEAR FUSION, 2020, 60 (03)
  • [45] Gyrokinetic simulation of short wavelength ion temperature gradient instabilities in the ADITYA-U tokamak
    Singh, Amit K. K.
    Mahapatra, J.
    Chowdhury, J.
    Aggarwal, D.
    Hayward-Schneider, T.
    Ganesh, R.
    Lanti, E.
    Villard, L.
    NUCLEAR FUSION, 2023, 63 (08)
  • [46] Plasma current and position feedback control in ADITYA Tokamak
    Balakrishnan, V
    Gupta, CN
    Sinha, RK
    FUSION ENGINEERING AND DESIGN, 2003, 66-68 : 809 - 813
  • [47] Calibration and signal processing methods used for density profile measurements from the developed FMCW reflectometry system for Aditya-U tokamak
    Buch, J. J. U.
    Pathak, Surya
    PLASMA PHYSICS AND CONTROLLED FUSION, 2025, 67 (04)
  • [48] Author Correction: Role of pinch in Argon impurity transport in ohmic discharges of Aditya-U Tokamak
    K. Shah
    J. Ghosh
    S. Patel
    M. B. Chowdhuri
    K. A. Jadeja
    G. Shukla
    T. Macwan
    A. Kumar
    S. Dolui
    K. Singh
    R. L. Tanna
    K. M. Patel
    R. Dey
    R. Manchanda
    N. Ramaiya
    R. Kumar
    S. Aich
    N. Yadava
    S. Purohit
    M. K. Gupta
    U. C. Nagora
    S. K. Pathak
    P. K. Atrey
    K. B. K. Mayya
    Scientific Reports, 13
  • [49] Determination of Eddy-Current Distribution in Electrically Isolated Vessel Sections of ADITYA-U Tokamak
    Kumar, Rohit
    Ghosh, J.
    Macwan, Tanmay
    Aich, Suman
    Tanna, R. L.
    Patel, Kaushal
    Jadeja, Kumarpal
    Jha, S. K.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2022, 50 (11) : 4279 - 4286
  • [50] Monitoring the behaviour of electromagnetic coil insulation under varying operational conditions in ADITYA-U tokamak
    Kumar, Rohit
    Raj, Harshita
    Pradhan, Laxmikanta
    Aich, Suman
    Singh, Kausalender
    Dolui, Suman
    Kumar, Ankit
    Hegde, Bharat
    Kumawat, Ashok
    Tanna, R. L.
    Ghosh, J.
    FUSION ENGINEERING AND DESIGN, 2024, 206